175 research outputs found
The K\"ahler-Ricci flow with positive bisectional curvature
We show that the K\"ahler-Ricci flow on a manifold with positive first Chern
class converges to a K\"ahler-Einstein metric assuming positive bisectional
curvature and certain stability conditions.Comment: 15 page
Outcomes of cardiac resynchronization therapy with or without defibrillation in patients with nonischemic cardiomyopathy
Background Recent studies have cast doubt on the benefit of cardiac resynchronization therapy (CRT) with defibrillation (CRT-D) versus pacing (CRT-P) for patients with nonischemic cardiomyopathy (NICM). Left ventricular myocardial scar portends poor clinical outcomes. Objectives The aim of this study was to determine whether CRT-D is superior to CRT-P in patients with NICM either with (+) or without (−) left ventricular midwall fibrosis (MWF), detected by cardiac magnetic resonance. Methods Clinical events were quantified in patients with NICM who were +MWF (n = 68) or −MWF (n = 184) who underwent cardiac magnetic resonance prior to CRT device implantation. Results In the total study population, +MWF emerged as an independent predictor of total mortality (adjusted hazard ratio [aHR]: 2.31; 95% confidence interval [CI]: 1.45 to 3.68), total mortality or heart failure hospitalization (aHR: 2.02; 95% CI: 1.32 to 3.09), total mortality or hospitalization for major adverse cardiac events (aHR: 2.02; 95% CI: 1.32 to 3.07), death from pump failure (aHR: 1.95; 95% CI: 1.11 to 3.41), and sudden cardiac death (aHR: 3.75; 95% CI: 1.26 to 11.2) over a maximum follow-up period of 14 years (median 3.8 years [interquartile range: 2.0 to 6.1 years] for +MWF and 4.6 years [interquartile range: 2.4 to 8.3 years] for −MWF). In separate analyses of +MWF and −MWF, total mortality (aHR: 0.23; 95% CI: 0.07 to 0.75), total mortality or heart failure hospitalization (aHR: 0.32; 95% CI: 0.12 to 0.82), and total mortality or hospitalization for major adverse cardiac events (aHR: 0.30; 95% CI: 0.12 to 0.78) were lower after CRT-D than after CRT-P in +MWF but not in −MWF. Conclusions In patients with NICM, CRT-D was superior to CRT-P in +MWF but not −MWF. These findings have implications for the choice of device therapy in patients with NICM
Long‐Term Outcomes of Cardiac Resynchronization Therapy Using Apical Versus Nonapical Left Ventricular Pacing
Background Experimental evidence indicates that left ventricular (LV) apical pacing is hemodynamically superior to nonapical LV pacing. Some studies have shown that an LV apical lead position is unfavorable in cardiac resynchronization therapy. We sought to determine whether an apical LV lead position influences cardiac mortality after cardiac resynchronization therapy. Methods and Results In this retrospective observational study, the primary end point of cardiac mortality was assessed in relation to longitudinal (basal, midventricular, or apical) and circumferential (anterior, lateral, or posterior) LV lead positions, as well as right ventricular (apical or septal), assigned using fluoroscopy. Lead positions were assessed in 1189 patients undergoing cardiac resynchronization therapy implantation over 15 years. After a median follow‐up of 6.0 years (interquartile range: 4.4–7.7 years), an apical LV lead position was associated with lower cardiac mortality than a nonapical position (adjusted hazard ratio: 0.74; 95% confidence interval, 0.56–0.99) after covariate adjustment. There were no differences in total mortality or heart failure hospitalization. Death from pump failure was lower with apical than nonapical positions (adjusted hazard ratio: 0.69; 95% confidence interval, 0.51–0.94). Compared with a basal position, an apical LV position was also associated with lower risk of sudden cardiac death (adjusted hazard ratio: 0.34; 95% confidence interval, 0.13–0.93). No differences emerged between circumferential LV lead positions or right ventricular positions with respect to any end point. Conclusions In recipients of cardiac resynchronization therapy, an apical LV lead position was associated with better long‐term cardiac survival than a nonapical position. This effect was due to a lower risk of pump failure and sudden cardiac death
Body-centered-cubic Ni and its magnetic properties
The body-centered-cubic (bec) phase of Ni, which does not exist in nature, has been achieved as a thin film on GaAs(001) at 170 K via molecular beam epitaxy. The bec Ni is ferromagnetic with a Curie temperature of 456 K and possesses a magnetic moment of 0.52 \uc2\ub1 0.08 \uce\ubcB/atom. The cubic magneto-crystalline anisotropy of bec Ni is determined to be +4.0 \uc3\u97 105 ergs \uc2\ub7 cm-3, as opposed to -5.7 \uc3\u97 10 4 ergs \uc2\ub7 cm-3 for the naturally occurring face-centered-cubic (fcc) Ni. This sharp contrast in the magnetic anisotropy is attributed to the different electronic band structures between bec Ni and fcc Ni, which are determined using angle-resolved photoemission with synchrotron radiation
Measurements of the Mass and Full-Width of the Meson
In a sample of 58 million events collected with the BES II detector,
the process J/ is observed in five different decay
channels: , , (with ), (with
) and . From a combined fit of all five
channels, we determine the mass and full-width of to be
MeV/ and
MeV/.Comment: 9 pages, 2 figures and 4 table. Submitted to Phys. Lett.
Direct Measurements of the Branching Fractions for and and Determinations of the Form Factors and
The absolute branching fractions for the decays and
are determined using singly
tagged sample from the data collected around 3.773 GeV with the
BES-II detector at the BEPC. In the system recoiling against the singly tagged
meson, events for and events for decays are observed. Those yield
the absolute branching fractions to be and . The
vector form factors are determined to be
and . The ratio of the two form
factors is measured to be .Comment: 6 pages, 5 figure
Measurements of J/psi Decays into 2(pi+pi-)eta and 3(pi+pi-)eta
Based on a sample of 5.8X 10^7 J/psi events taken with the BESII detector,
the branching fractions of J/psi--> 2(pi+pi-)eta and J/psi-->3(pi+pi-)eta are
measured for the first time to be (2.26+-0.08+-0.27)X10^{-3} and
(7.24+-0.96+-1.11)X10^{-4}, respectively.Comment: 11 pages, 6 figure
BESII Detector Simulation
A Monte Carlo program based on Geant3 has been developed for BESII detector
simulation. The organization of the program is outlined, and the digitization
procedure for simulating the response of various sub-detectors is described.
Comparisons with data show that the performance of the program is generally
satisfactory.Comment: 17 pages, 14 figures, uses elsart.cls, to be submitted to NIM
Measurement of branching fractions for the inclusive Cabibbo-favored ~K*0(892) and Cabibbo-suppressed K*0(892) decays of neutral and charged D mesons
The branching fractions for the inclusive Cabibbo-favored ~K*0 and
Cabibbo-suppressed K*0 decays of D mesons are measured based on a data sample
of 33 pb-1 collected at and around the center-of-mass energy of 3.773 GeV with
the BES-II detector at the BEPC collider. The branching fractions for the
decays D+(0) -> ~K*0(892)X and D0 -> K*0(892)X are determined to be BF(D0 ->
\~K*0X) = (8.7 +/- 4.0 +/- 1.2)%, BF(D+ -> ~K*0X) = (23.2 +/- 4.5 +/- 3.0)% and
BF(D0 -> K*0X) = (2.8 +/- 1.2 +/- 0.4)%. An upper limit on the branching
fraction at 90% C.L. for the decay D+ -> K*0(892)X is set to be BF(D+ -> K*0X)
< 6.6%
- …