6,376 research outputs found
Infrared spectra of van de Waals complexes of importance in planetary atmospheres
It has been suggested that (CO2)2 and Ar-CO2 are important constituents of the planetary atmospheres of Venus and Mars. Recent results on the laboratory spectroscopy of CO2 containing van der Waals complexes which may be of use in the modeling of the spectra of planetary atmospheres are presented. Sub-Doppler infrared spectra were obtained for (CO2)2, (CO2)3, and rare-gas-CO2 complexes in the vicinity of the CO2 Fermi diad at 2.7 micrometers using a color-center-laser optothermal spectrometer. From the spectroscopic constants the geometries of the complexes have been determined and van der Waals vibrational frequencies have been estimated. The equilibrium configurations are C2h, C3h, and C2v, for (CO2)2, (CO2)3, and the rare-gas-CO2 complexes, respectively. Most of the homogeneous linewidths for the revibrational transitions range from 0.5 to 22 MHz, indicating that predissociation is as much as four orders of magnitude faster than radiative processes for vibrational relaxation in these complexes
Substituent Effects in Unimolecular Ion Decompositions. III - Elucidation of Competing Alternative Pathways for the Formation of a Particular Ion
Alternative means for formation of molecular ion in mass spectr
A feasibility study of limb volume measuring systems
Evaluation of the various techniques by which limb volume can be measured indicates that the odometric (electromechanical) method and the reflective scanner (optical) have a high probability of meeting the specifications of the LBNP experiments. Both of these methods provide segmental measurements from which the cross sectional area of the limb can be determined
Evanescent Eave Imaging in Optical Lithograpy
New applications of evanescent imaging for microlithography are introduced. The use of evanescent wave lithography (EWL) has been employed for 26nm resolution at 1.85NA using a 193nm ArF excimer laser wavelength to record images in a photoresist with a refractive index of 1.71. Additionally, a photomask enhancement effect is described using evanescent wave assist features (EWAF) to take advantage of the coupling of the evanescent energy bound at the substrate-absorber surface, enhancing the transmission of a mask opening through coupled interference
Dynamic telomerase gene suppression via network effects of GSK3 inhibition
<b>Background</b>: Telomerase controls telomere homeostasis and cell immortality and is a promising anti-cancer target, but few small molecule telomerase inhibitors have been developed. Reactivated transcription of the catalytic subunit hTERT in cancer cells controls telomerase expression. Better understanding of upstream pathways is critical for effective anti-telomerase therapeutics and may reveal new targets to inhibit hTERT expression.
<b>Methodology/Principal Findings</b>: In a focused promoter screen, several GSK3 inhibitors suppressed hTERT reporter activity. GSK3 inhibition using 6-bromoindirubin-3′-oxime suppressed hTERT expression, telomerase activity and telomere length in several cancer cell lines and growth and hTERT expression in ovarian cancer xenografts. Microarray analysis, network modelling and oligonucleotide binding assays suggested that multiple transcription factors were affected. Extensive remodelling involving Sp1, STAT3, c-Myc, NFκB, and p53 occurred at the endogenous hTERT promoter. RNAi screening of the hTERT promoter revealed multiple kinase genes which affect the hTERT promoter, potentially acting through these factors. Prolonged inhibitor treatments caused dynamic expression both of hTERT and of c-Jun, p53, STAT3, AR and c-Myc.
<b>Conclusions/Significance</b>: Our results indicate that GSK3 activates hTERT expression in cancer cells and contributes to telomere length homeostasis. GSK3 inhibition is a clinical strategy for several chronic diseases. These results imply that it may also be useful in cancer therapy. However, the complex network effects we show here have implications for either setting
A cost-effective fluorescence detection system for pulsed laser analysis
A cost-effective fluorescence detection system has been developed using a National Instruments PCI-6251 data acquisition (DAQ) board that is driven by LabVIEW Signal Express. The signal is collected using a collimator and transported to the DAQ board using a fiber-coupled detector. The same detection system has been incorporated into an inverted microscope fitted with internal dichroic mirrors to provide a cost-effective alternative to commercial fluorescence microscopes. The detection system has been used to measure fluorescence intensity and generate a laser power curve that can be used for pulsed lasers. Different data analysis approaches have been compared and standard deviation and signal-to-noise ratios have been determined
- …