1,069 research outputs found

    Beam-Based Alignment of the NuMI Target Station Components at FNAL

    Get PDF
    The Neutrinos at the Main Injector (NuMI) facility is a conventional horn-focused neutrino beam which produces muon neutrinos from a beam of mesons directed into a long evacuated decay volume. The relative alignment of the primary proton beam, target, and focusing horns affects the neutrino energy spectrum delivered to experiments. This paper describes a check of the alignment of these components using the proton beam.Comment: higher resolution figures available on Fermilab Preprint Server (see SPIRES entry), accepted for publication in Nucl. Instr. and Meth.

    Numerical simulations of current generation and dynamo excitation in a mechanically-forced, turbulent flow

    Full text link
    The role of turbulence in current generation and self-excitation of magnetic fields has been studied in the geometry of a mechanically driven, spherical dynamo experiment, using a three dimensional numerical computation. A simple impeller model drives a flow which can generate a growing magnetic field, depending upon the magnetic Reynolds number, Rm, and the fluid Reynolds number. When the flow is laminar, the dynamo transition is governed by a simple threshold in Rm, above which a growing magnetic eigenmode is observed. The eigenmode is primarily a dipole field tranverse to axis of symmetry of the flow. In saturation the Lorentz force slows the flow such that the magnetic eigenmode becomes marginally stable. For turbulent flow, the dynamo eigenmode is suppressed. The mechanism of suppression is due to a combination of a time varying large-scale field and the presence of fluctuation driven currents which effectively enhance the magnetic diffusivity. For higher Rm a dynamo reappears, however the structure of the magnetic field is often different from the laminar dynamo; it is dominated by a dipolar magnetic field which is aligned with the axis of symmetry of the mean-flow, apparently generated by fluctuation-driven currents. The fluctuation-driven currents have been studied by applying a weak magnetic field to laminar and turbulent flows. The magnetic fields generated by the fluctuations are significant: a dipole moment aligned with the symmetry axis of the mean-flow is generated similar to those observed in the experiment, and both toroidal and poloidal flux expulsion are observed.Comment: 14 pages, 14 figure

    How a Diverse Research Ecosystem Has Generated New Rehabilitation Technologies: Review of NIDILRR’s Rehabilitation Engineering Research Centers

    Get PDF
    Over 50 million United States citizens (1 in 6 people in the US) have a developmental, acquired, or degenerative disability. The average US citizen can expect to live 20% of his or her life with a disability. Rehabilitation technologies play a major role in improving the quality of life for people with a disability, yet widespread and highly challenging needs remain. Within the US, a major effort aimed at the creation and evaluation of rehabilitation technology has been the Rehabilitation Engineering Research Centers (RERCs) sponsored by the National Institute on Disability, Independent Living, and Rehabilitation Research. As envisioned at their conception by a panel of the National Academy of Science in 1970, these centers were intended to take a “total approach to rehabilitation”, combining medicine, engineering, and related science, to improve the quality of life of individuals with a disability. Here, we review the scope, achievements, and ongoing projects of an unbiased sample of 19 currently active or recently terminated RERCs. Specifically, for each center, we briefly explain the needs it targets, summarize key historical advances, identify emerging innovations, and consider future directions. Our assessment from this review is that the RERC program indeed involves a multidisciplinary approach, with 36 professional fields involved, although 70% of research and development staff are in engineering fields, 23% in clinical fields, and only 7% in basic science fields; significantly, 11% of the professional staff have a disability related to their research. We observe that the RERC program has substantially diversified the scope of its work since the 1970’s, addressing more types of disabilities using more technologies, and, in particular, often now focusing on information technologies. RERC work also now often views users as integrated into an interdependent society through technologies that both people with and without disabilities co-use (such as the internet, wireless communication, and architecture). In addition, RERC research has evolved to view users as able at improving outcomes through learning, exercise, and plasticity (rather than being static), which can be optimally timed. We provide examples of rehabilitation technology innovation produced by the RERCs that illustrate this increasingly diversifying scope and evolving perspective. We conclude by discussing growth opportunities and possible future directions of the RERC program

    Observation of anomalous decoherence effect in a quantum bath at room temperature

    Get PDF
    Decoherence of quantum objects is critical to modern quantum sciences and technologies. It is generally believed that stronger noises cause faster decoherence. Strikingly, recent theoretical research discovers the opposite case for spins in quantum baths. Here we report experimental observation of the anomalous decoherence effect for the electron spin-1 of a nitrogen-vacancy centre in high-purity diamond at room temperature. We demonstrate that under dynamical decoupling, the double-transition can have longer coherence time than the single-transition, even though the former couples to the nuclear spin bath as twice strongly as the latter does. The excellent agreement between the experimental and the theoretical results confirms the controllability of the weakly coupled nuclear spins in the bath, which is useful in quantum information processing and quantum metrology.Comment: 22 pages, related paper at http://arxiv.org/abs/1102.557

    Influence of a Dy overlayer on the precessional dynamics of a ferromagnetic thin film

    Get PDF
    This is the final version of the article. Available from the American Institute of Physics via the DOI in this record.Precessional dynamics of a Co50Fe50(0.7)/Ni 90Fe10(5)/Dy(1)/Ru(3) (thicknesses in nm) thin film have been explored by low temperature time-resolved magneto-optical Kerr effect and phase-resolved x-ray ferromagnetic resonance measurements. As the temperature was decreased from 300 to 140 K, the magnetic damping was found to increase rapidly while the resonance field was strongly reduced. Static x-ray magnetic circular dichroism measurements revealed increasing ferromagnetic order of the Dy moment antiparallel to that of Co50Fe50/Ni 90Fe10. Increased coupling of the Dy orbital moment to the precessing spin magnetization leads to significantly increased damping and gyromagnetic ratio of the film while leaving its magnetic anisotropy effectively unchanged.The authors gratefully acknowledge the financial support of EPSRC Grant EP/F021755/1. The ALS is supported by the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Parts of this work were carried out on beamline 4.0.2 at the ALS and beamline I06-1 at Diamond Light Source
    • …
    corecore