362 research outputs found
Current Results of the EC-sponsored Catchment Modelling (CatchMod) Cluster
To support the Water Framework Directive implementation, much research has been commissioned at both national and European levels. CatchMod is a cluster of these projects, which is focusing on the development of computational catchment models and related tools. This paper presents an overview of the results of the CatchMod cluster to dat
Web-based multimodal graphs for visually impaired people
This paper describes the development and evaluation of Web-based multimodal graphs designed for visually impaired and blind people. The information in the graphs is conveyed to visually impaired people through haptic and audio channels. The motivation of this work is to address problems faced by visually impaired people in accessing graphical information on the Internet, particularly the common types of graphs for data visualization. In our work, line graphs, bar charts and pie charts are accessible through a force feedback device, the Logitech WingMan Force Feedback Mouse. Pre-recorded sound files are used to represent graph contents to users. In order to test the usability of the developed Web graphs, an evaluation was conducted with bar charts as the experimental platform. The results showed that the participants could successfully use the haptic and audio features to extract information from the Web graphs
Reconstructing a Simple Polytope from its Graph
Blind and Mani (1987) proved that the entire combinatorial structure (the
vertex-facet incidences) of a simple convex polytope is determined by its
abstract graph. Their proof is not constructive. Kalai (1988) found a short,
elegant, and algorithmic proof of that result. However, his algorithm has
always exponential running time. We show that the problem to reconstruct the
vertex-facet incidences of a simple polytope P from its graph can be formulated
as a combinatorial optimization problem that is strongly dual to the problem of
finding an abstract objective function on P (i.e., a shelling order of the
facets of the dual polytope of P). Thereby, we derive polynomial certificates
for both the vertex-facet incidences as well as for the abstract objective
functions in terms of the graph of P. The paper is a variation on joint work
with Michael Joswig and Friederike Koerner (2001).Comment: 14 page
The Influence of Strategic Patenting on Companies’ Patent Portfolios
This paper analyses whether strategic motives for patenting influence the characteristics of companies’ patent portfolios. We use the number of citations and oppositions to represent these characteristics. The investigation is based on survey and patent data from German companies. We find clear evidence that the companies’ patenting strategies explain the characteristics of their patent portfolios. First, companies using patents to protect their technological knowledge base receive a higher number of citations for their patents. Second, the motive of offensive – but not of defensive – blocking is related to a higher incidence of oppositions, whereas companies using patents as bartering chips in collaborations receive fewer oppositions to their patents
GRAVITY: the Calibration Unit
We present in this paper the design and characterisation of a new sub-system
of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The
Calibration Unit provides all functions to test and calibrate the beam combiner
instrument: it creates two artificial stars on four beams, and dispose of four
delay lines with an internal metrology. It also includes artificial stars for
the tip-tilt and pupil guiding systems, as well as four metrology pick-up
diodes, for tests and calibration of the corresponding sub-systems. The
calibration unit also hosts the reference targets to align GRAVITY to the VLTI,
and the safety shutters to avoid the metrology light to propagate in the
VLTI-lab. We present the results of the characterisation and validtion of these
differrent sub-units.Comment: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared
Interferometry IV
Cytotoxic activity of the sub-fraction 2125 from Vernonia scorpioides against Sarcoma 180 tumor cells in mice
The effect of the selected sub-fraction SF-2125 of the Vernonia scorpioides leaf extract on Sarcoma 180 (S180) ascitic tumor-bearing mice was investigated. The animals were treated with SF-2125 at a concentration of 5 mg/kg, administered intraperitoneally and intravenous during the development of the tumor. Treatment with SF-2125 5 mg/kg i.p. increased the lifespan of the animals, maintained their body and the ascitic tumor showed no development. Intravenous treatment did not reduce the tumor volume
The GRAVITY metrology system: modeling a metrology in optical fibers
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for
high-precision narrow-angle astrometry and phase-referenced interferometric
imaging. The laser metrology system of GRAVITY is at the heart of its
astrometric mode, which must measure the distance of 2 stars with a precision
of 10 micro-arcseconds. This means the metrology has to measure the optical
path difference between the two beam combiners of GRAVITY to a level of 5 nm.
The metrology design presents some non-common paths that have consequently to
be stable at a level of 1 nm. Otherwise they would impact the performance of
GRAVITY. The various tests we made in the past on the prototype give us hints
on the components responsible for this error, and on their respective
contribution to the total error. It is however difficult to assess their exact
origin from only OPD measurements, and therefore, to propose a solution to this
problem. In this paper, we present the results of a semi-empirical modeling of
the fibered metrology system, relying on theoretical basis, as well as on
characterisations of key components. The modeling of the metrology system
regarding various effects, e.g., temperature, waveguide heating or mechanical
stress, will help us to understand how the metrology behave. The goals of this
modeling are to 1) model the test set-ups and reproduce the measurements (as a
validation of the modeling), 2) determine the origin of the non-common path
errors, and 3) propose modifications to the current metrology design to reach
the required 1nm stability.Comment: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared
Interferometry IV
Polytopality and Cartesian products of graphs
We study the question of polytopality of graphs: when is a given graph the
graph of a polytope? We first review the known necessary conditions for a graph
to be polytopal, and we provide several families of graphs which satisfy all
these conditions, but which nonetheless are not graphs of polytopes. Our main
contribution concerns the polytopality of Cartesian products of non-polytopal
graphs. On the one hand, we show that products of simple polytopes are the only
simple polytopes whose graph is a product. On the other hand, we provide a
general method to construct (non-simple) polytopal products whose factors are
not polytopal.Comment: 21 pages, 10 figure
- …