275 research outputs found

    Conceptual design and analysis of orbital cryogenic liquid storage and supply systems

    Get PDF
    A wide variety of orbital cryogenic liquid storage and supply systems are defined in NASA and DOD long-range plans. These systems include small cooling applications, large chemical and electrical orbit transfer vehicles and supply tankers. All have the common requirements of low-g fluid management to accomplish gas-free liquid expulsion and efficient thermal control to manage heat leak and tank pressure. A preliminary design study was performed to evaluate tanks ranging from 0.6 to 37.4 cu m (22 to 1320 cu ft). Liquids of interest were hydrogen, oxygen, methane, argon and helium. Conceptual designs were generated for each tank system and fluid dynamic, thermal and structural analyses were performed for Shuttle compatible operations. Design trades considered the paradox of conservative support structure and minimum thermal input. Orbital performance and weight data were developed, and a technology evaluation was completed

    Thermal performance of multilayer insulations Interim report

    Get PDF
    Heat flux and optical property measurement for multilayer insulatio

    Attenuation of neural responses in primary visual cortex during the attentional blink

    Get PDF
    Information-processing bottlenecks are characteristic of many cognitive and neural systems. One such bottleneck is revealed by tasks in which rapidly successive stimulus events must be reported. Here, observers missed the second of two visual targets if it occurred within 700 ms of the first [an "attentional blink" (AB)], even though this second target could be reported accurately when the first item was ignored. Isolating neural responses to such rapid events has proven difficult because current magnetic resonance imaging methods rely on relatively sluggish changes in the brain's physiological response to sensory inputs. Here, we overcame this limitation by presenting successive visual targets at different spatial locations, thereby exploiting the retinotopic organization of early cortical visual areas to distinguish neural activity associated with successive target events. We show that neural activity in primary visual cortex is significantly modulated during the AB, and that this activity mirrors behavioral measures of target identification accuracy. The findings suggest that the neural signature of perceptual suppression during processing of rapidly successive stimuli is evident at the earliest stages of cortical sensory processing

    Thermal performance of multilayer insulations

    Get PDF
    Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank

    Lessons from the pandemic: new best practices in selecting molecular diagnostics for point-of-care testing of infectious diseases in sub-Saharan Africa

    Get PDF
    Introduction: Point-of-care molecular diagnostics offer solutions to the limited diagnostic availability and accessibility in resource-limited settings. During the COVID-19 pandemic, molecular diagnostics became essential tools for accurate detection and monitoring of SARS-CoV-2. The unprecedented demand for molecular diagnostics presented challenges and catalyzed innovations which may provide lessons for the future selection of point-of-care molecular diagnostics. Areas Covered: We searched PubMed from January 2020 to August 2023 to identify lessons learned from the COVID-19 pandemic which may impact the selection of point-of-care molecular diagnostics for future use in sub-Saharan Africa. We evaluated this in the context of REASSURED criteria (Real-time connectivity; Ease of specimen collection; Affordable; Sensitive; Specific; User-friendly; Rapid and robust; Equipment free; and Deliverable to users at the point of need) for point-of-care diagnostics for resource-limited settings. Expert Opinion: The diagnostic challenges and successes during the COVID-19 pandemic affirmed the importance of the REASSURED criteria but demonstrated that these are not sufficient to ensure new diagnostics will be appropriate for public health emergencies. Capacity for rapid scale-up of diagnostic testing and transferability of assays, data, and technology are also important, resulting in updated REST-ASSURED criteria. Few diagnostics will meet all criteria, and trade-offs between criteria will need to be context-specific

    Cardiac sodium channel inhibition by lamotrigine: in vitro characterization and clinical implications

    Get PDF
    Lamotrigine, approved for use as an antiseizure medication (ASM) as well as the treatment of bipolar disorder, inhibits sodium channels in the brain to reduce repetitive neuronal firing and pathological release of glutamate. The shared homology of sodium channels and lack of selectivity associated with channel blocking agents can cause slowing of cardiac conduction and increased proarrhythmic potential. The Vaughan-Williams classification system differentiates sodium channel blockers using biophysical properties of binding. As such, Class Ib inhibitors including mexiletine do not slow cardiac conduction as measured by the electrocardiogram (ECG), at therapeutically relevant exposure. Our goal was to characterize the biophysical properties of NaV 1.5 block and to support the observed clinical safety of lamotrigine. We used HEK-293 cells stably expressing the hNaV 1.5 channel and voltage clamp electrophysiology to quantify the potency (IC50 ) against peak and late channel current, on-/off-rate binding kinetics, voltage-dependence and tonic block of the cardiac sodium channel by lamotrigine; and compared to clinically relevant Class Ia (quinidine), Ib (mexiletine) and Ic (flecainide) inhibitors. Lamotrigine blocked peak and late NaV 1.5 current at therapeutically relevant exposure, with rapid kinetics and biophysical properties similar to the Class Ib inhibitor mexiletine. However, no clinically meaningful prolongation in QRS or PR interval was observed in healthy subjects in a new analysis of a previously reported thorough QT clinical trial (SCA104648). In conclusion, the weak NaV 1.5 block and rapid kinetics do not translate into clinically relevant conduction slowing at therapeutic exposure and support the clinical safety of lamotrigine in patients suffering from epilepsy and bipolar disorder

    Ready ... Go: Amplitude of the fMRI Signal Encodes Expectation of Cue Arrival Time

    Get PDF
    What happens when the brain awaits a signal of uncertain arrival time, as when a sprinter waits for the starting pistol? And what happens just after the starting pistol fires? Using functional magnetic resonance imaging (fMRI), we have discovered a novel correlate of temporal expectations in several brain regions, most prominently in the supplementary motor area (SMA). Contrary to expectations, we found little fMRI activity during the waiting period; however, a large signal appears after the “go” signal, the amplitude of which reflects learned expectations about the distribution of possible waiting times. Specifically, the amplitude of the fMRI signal appears to encode a cumulative conditional probability, also known as the cumulative hazard function. The fMRI signal loses its dependence on waiting time in a “countdown” condition in which the arrival time of the go cue is known in advance, suggesting that the signal encodes temporal probabilities rather than simply elapsed time. The dependence of the signal on temporal expectation is present in “no-go” conditions, demonstrating that the effect is not a consequence of motor output. Finally, the encoding is not dependent on modality, operating in the same manner with auditory or visual signals. This finding extends our understanding of the relationship between temporal expectancy and measurable neural signals

    Death and Display in the North Atlantic: The Bronze and Iron Age Human Remains from Cnip, Lewis, Outer Hebrides

    Get PDF
    YesThis paper revisits the series of disarticulated human remains discovered during the 1980s excavations of the Cnip wheelhouse complex in Lewis. Four fragments of human bone, including two worked cranial fragments, were originally dated to the 1st centuries BC/AD based on stratigraphic association. Osteoarchaeological reanalysis and AMS dating now provide a broader cultural context for these remains and indicate that at least one adult cranium was brought to the site more than a thousand years after the death of the individual to whom it had belonged

    Action selection and action awareness

    Get PDF
    Human actions are often classified as either internally generated, or externally specified in response to environmental cues. These two modes of action selection have distinct neural bases, but few studies investigated how the mode of action selection affects the subjective experience of action. We measured the experience of action using the subjective compression of the interval between actions and their effects, known as ‘temporal binding’. Participants performed either a left or a right key press, either in response to a specific cue, or as they freely chose. Moreover, the time of each keypress could either be explicitly cued to occur in one of two designated time intervals, or participants freely chose in which interval to act. Each action was followed by a specific tone. Participants judged the time of their actions or the time of the tone. Temporal binding was found for both internally generated and for stimulus-based actions. However, the amount of binding depended on whether or not both the choice and the timing of action were selected in the same way. Stronger binding was observed when both action choice and action timing were internally generated or externally specified, compared to conditions where the two parameters were selected by different routes. Our result suggests that temporal action–effect binding depends on how actions are selected. Binding is strongest when actions result from a single mode of selection
    corecore