3,440 research outputs found
Performance of a 1.15-pressure-ratio axial-flow fan stage with a blade tip solidity of 0.5
The overall and blade-element performance of a low-solidity, low-pressure-ratio, low-tip-speed fan stage is presented over the stable operating range at rotative speeds from 90 to 120 percent of design speed. At design speed a stage peak efficiency of 0.836 was obtained at a weight flow of 30.27 kilograms per second and a pressure ratio of 1.111. The pressure ratio was less than design pressure ratio, and the design energy input into the rotor was not achieved. A mismatch of the rotor and stator blade elements resulted due to the lower than design pressure ratio of the rotor
Aerodynamic performance of a 1.35-pressure-ratio axial-flow fan stage
The overall blade element performances and the aerodynamic design parameters are presented for a 1.35-pressure-ratio fan stage. The fan stage was designed for a weight flow of 32.7 kilograms per second and a tip speed of 302.8 meters per second. At design speed the stage peak efficiency of 0.879 occurred at a pressure ratio of 1.329 and design flow. Stage stall margin was approximately 14 percent. At design flow rotor efficiency was 0.94 and the pressure ratio was 1.360
Stalled and stall-free performance of axial-flow compressor stage with three inlet-guide-vane and stator-blade settings
The performance of the first stage of a transonic, multistage compressor was mapped over a range of inlet-guide-vane and stator-blade settings. Both stall-free and deep-stall performance data were obtained. For the settings tested, as stall was encountered and flow was further reduced, a relatively sharp drop in pressure ratio occurred and was followed by a continuing but more gradual reduction in pressure ratio with reduced flow. The position of the stall line on the map of pressure ratio against equivalent weight flow was essentially unaffected over the range of inlet-guide-vane and stator-blade settings
Performance of inlet stage of transonic compressor
The overall and blade-element performances are presented over the stable flow operating range of the stage at the design tip speed of 426 m/sec. Stage peak efficiency of 0.83 was obtained at a weight flow of 28.8 kg/sec and a pressure ratio of 1.52. The stall margin for the stage was 8 percent based on weight flow and pressure ratio at peak efficiency and stall. The rotor appears to be stalling prematurely as evidenced by high rotor tip losses
Th2 cytokines and asthma — Interleukin-4: its role in the pathogenesis of asthma, and targeting it for asthma treatment with interleukin-4 receptor antagonists
Interleukin-4 (IL-4) mediates important pro-inflammatory functions in asthma including induction of the IgE isotype switch, expression of vascular cell adhesion molecule-1 (VCAM-1), promotion of eosinophil transmigration across endothelium, mucus secretion, and differentiation of T helper type 2 lymphocytes leading to cytokine release. Asthma is a complex genetic disorder that has been linked to polymorphisms in the IL-4 gene promoter and proteins involved in IL-4 signaling. Soluble recombinant IL-4 receptor lacks transmembrane and cytoplasmic activating domains and can therefore sequester IL-4 without mediating cellular activation. We report the results of initial clinical trials, which demonstrate clinical efficacy of this naturally occurring IL-4 antagonist as a therapeutic agent in asthma
Unusual cross-sectional imaging findings in hepatic peliosis
Abstract.: Hepatic peliosis is a rare entity that represents focal, multifocal, segmental, or diffuse dilatation of liver sinusoids. Hepatic peliosis is often associated with chronic wasting diseases but also has been reported in association with anabolic, contraceptive, or other hormonal treatment, and even in context with HIV-related bacterial infections. Hepatic peliosis is usually clinically unapparent and mostly found only during autopsy, but occasionally it may lead to diagnostic problems if detected radiologically since the imaging findings in hepatic peliosis are quite variable according to the variety of its possible histologic features as well as the possibility of additional hemorrhage. We present a case of hepatic peliosis associated with bronchial carcinoma that showed moderate centripetal enhancement during the portal-venous phase on CT, pronounced venous pooling on contrast enhanced T1-weighted images acquired during the hepatic-venous phase, and bright signal on T2-weighted images, thus mimicking in some way a capillary hemangioma. We also discuss some not yet described CT and MR features of this rare entity which should be included into the differential diagnosis of atypical liver lesions in patients with the above-mentioned condition
The role of quantum fluctuations in the optomechanical properties of a Bose-Einstein condensate in a ring cavity
We analyze a detailed model of a Bose-Einstein condensate trapped in a ring
optical resonator and contrast its classical and quantum properties to those of
a Fabry-P{\'e}rot geometry. The inclusion of two counter-propagating light
fields and three matter field modes leads to important differences between the
two situations. Specifically, we identify an experimentally realizable region
where the system's behavior differs strongly from that of a BEC in a
Fabry-P\'{e}rot cavity, and also where quantum corrections become significant.
The classical dynamics are rich, and near bifurcation points in the mean-field
classical system, the quantum fluctuations have a major impact on the system's
dynamics.Comment: 11 pages, 11 figures, submitted to PR
Quantum Collective QCD String Dynamics
The string breaking model of particle production is extended in order to help
explain the transverse momentum distribution in elementary collisions. Inspired
by an idea of Bialas', we treat the string using a collective coordinate
approach. This leads to a chromo-electric field strength which fluctuates, and
in turn implies that quarks are produced according to a thermal distribution.Comment: 6 pages. Presented at SQM 2006. Submitted to J. Phys. G for
publication in proceedings. Vers. 2: Minor revisions; final hadron spectrum
calculation include
- …