4,295 research outputs found

    Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II

    Full text link
    Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are available in large sizes, are of low cost and, like diamond sensors, can be operated without cooling. Here we present results of an irradiation study done with sapphire sensors in a high intensity low energy electron beam. Then, a multichannel direction-sensitive sapphire detector stack is described. It comprises 8 sapphire plates of 1 cm^2 size and 525 micro m thickness, metallized on both sides, and apposed to form a stack. Each second metal layer is supplied with a bias voltage, and the layers in between are connected to charge-sensitive preamplifiers. The performance of the detector was studied in a 5 GeV electron beam. The charge collection efficiency measured as a function of the bias voltage rises with the voltage, reaching about 10 % at 950 V. The signal size obtained from electrons crossing the stack at this voltage is about 22000 e, where e is the unit charge. The signal size is measured as a function of the hit position, showing variations of up to 20 % in the direction perpendicular to the beam and to the electric field. The measurement of the signal size as a function of the coordinate parallel to the electric field confirms the prediction that mainly electrons contribute to the signal. Also evidence for the presence of a polarisation field was observed.Comment: 13 pages, 7 figures, 3 table

    Triaxial nuclear models and the outer crust of nonaccreting cold neutron stars

    Get PDF
    The properties and composition of the outer crust of nonaccreting cold neutron stars are studied by applying the model of Baym, Pethick, and Sutherland (BPS) and taking into account for the first time triaxial deformations of nuclei. Two theoretical nuclear models, Hartree-Fock plus pairing in the BCS approximation (HF-BCS) with Skyrme SLy6 parametrization and Hartree-Fock-Bogolyubov (HFB) with Gogny D1S force, are used to calculate the nuclear masses. The two theoretical calculations are compared concerning their neutron drip line, binding energies, magic neutron numbers, and the sequence of nuclei in the outer crust of nonaccreting cold neutron stars, with special emphasis on the effect of triaxial deformations. The BPS model is extended by the higher-order corrections for the atomic binding, screening, exchange and zero-point energies. The influence of the higher-order corrections on the sequence of the outer crust is investigated.Comment: 7 page

    The outer crust of non-accreting cold neutron stars

    Get PDF
    The properties of the outer crust of non-accreting cold neutron stars are studied by using modern nuclear data and theoretical mass tables updating in particular the classic work of Baym, Pethick and Sutherland. Experimental data from the atomic mass table from Audi, Wapstra, and Thibault of 2003 is used and a thorough comparison of many modern theoretical nuclear models, relativistic and non-relativistic ones, is performed for the first time. In addition, the influences of pairing and deformation are investigated. State-of-the-art theoretical nuclear mass tables are compared in order to check their differences concerning the neutron dripline, magic neutron numbers, the equation of state, and the sequence of neutron-rich nuclei up to the dripline in the outer crust of non-accreting cold neutron stars.Comment: 20 pages, 10 figures, accepted for publication in Phys. Rev.

    Dynamic changes in host-virus interactions associated with colony founding and social environment in fire ant queens (Solenopsis invicta)

    Get PDF
    Funding Information US Department of Agriculture AFRI Award. Grant Number: 2009‐35302‐05301 Marie Curie International Incoming Fellowship. Grant Number: FP7‐PEOPLE‐2013‐IIF‐625487Peer reviewedPublisher PD

    Use of oxygen sensors for the non destructive measurement of oxygen in packaged food and beverage products and its impact on product quality and shelf life

    Get PDF
    The principal objective of this thesis was to investigate the ability of reversible optical O2 sensors to be incorporated into food/beverage packaging systems to continuously monitor O2 levels in a non-destructive manner immediately postpackaging and over time. Residual levels of O2 present in packs can negatively affect product quality and subsequently, product shelf-life, especially for O2-sensitive foods/beverages. Therefore, the ability of O2 sensors to continuously monitor O2 levels present within food/beverage packages was considered commercially relevant in terms of identifying the consequences of residual O2 on product safety and quality over time. Research commenced with the development of a novel range of O2 sensors based on phosphorescent platinum and palladium octaethylporphyrin-ketones (OEPk) in nano-porous high density polyethylene (HDPE), polypropylene (PP) polytetrafluoroethylene (PTFE) polymer supports. Sensors were calibrated over a temperature range of -10°C to +40°C and deemed suitable for food and beverage packaging applications. This sensor technology was used and demonstrated itself effective in determining failures in packaging containment. This was clearly demonstrated in the packaging of cheese string products. The sensor technology was also assessed across a wide range of packaged products; beer, ready-to-eat salad products, bread and convenience-style, muscle-based processed food products. The O2 sensor technology performed extremely well within all packaging systems. The sensor technology adequately detected O2 levels in; beer bottles prior to and following pasteurisation, modified atmosphere (MA) packs of ready-to-eat salad packs as respiration progressed during product storage and MA packs of bread and convenience-style muscle-based products as mycological growth occurred in food packs over time in the presence and absence of ethanol emitters. The use of the technology, in conjunction with standard food quality assessment techniques, showed remarkable usefulness in determining the impact of actual levels of O2 on specific quality attributes. The O2 sensing probe was modified, miniaturised and automated to screen for the determination of total aerobic viable counts (TVC) in several fish species samples. The test showed good correlation with conventional TVC test (ISO:4833:2003), analytical performance and ruggedness with respect to variation of key assay parameters (probe concentration and pipetting volume). Overall, the respirometric fish TVC test was simple to use, possessed a dynamic microbial range (104-107 cfu/g sample), had an accuracy of +/- one log(cfu/g sample) and was rapid. Its ability to assess highly perishable products such as fish for total microbial growth in <12 hr demonstrates commercial potential

    The rapidly oscillating Ap star HD 99563 and its distorted dipole pulsation mode

    Full text link
    We undertook a time-series photometric multi-site campaign for the rapidly oscillating Ap star HD 99563 and also acquired mean light observations over two seasons. The pulsations of the star, that show flatter light maxima than minima, can be described with a frequency quintuplet centred on 1557.653 microHertz and some first harmonics of these. The amplitude of the pulsation is modulated with the rotation period of the star that we determine with 2.91179 +/- 0.00007 d from the analysis of the stellar pulsation spectrum and of the mean light data. We break the distorted oscillation mode up into its pure spherical harmonic components and find it is dominated by the l=1 pulsation, and also has a notable l=3 contribution, with weak l=0 and 2 components. The geometrical configuration of the star allows one to see both pulsation poles for about the same amount of time; HD 99563 is only the fourth roAp star for which both pulsation poles are seen and only the third where the distortion of the pulsation modes was modelled. We point out that HD 99563 is very similar to the well-studied roAp star HR 3831. Finally, we note that the visual companion of HD 99563 is located in the Delta Scuti instability strip and may thus show pulsation. We show that if the companion was physical, the roAp star would be a 2.03 solar mass object, seen at a rotational inclination of 44 degrees, which then predicts a magnetic obliquity of 86.4 degrees.Comment: 10 pages, 6 figures, accepted for publication by MNRA

    Extragalactic Globular Clusters in the Near-Infrared: V. IC 4051 and NGC 3311

    Full text link
    We present the results of combined optical and near-infrared photometry for the globular cluster systems of the giant ellipticals IC 4051 and NGC 3311. We use the reduced age-metallicity degeneracy in (V-I) vs.(V-H) color-color diagrams to derive the cumulative age distribution within the red sub-population of globular clusters and to search for age sub-populations. The age distribution is then compared to the one determined for simulated globular cluster systems in order to set constraints on the relative age and size of these globular cluster sub-populations. In both galaxies we find a significant fraction of globular clusters with ages between 2- 5 Gyr. We also investigate the metallicity distribution in both systems. Small number statistics prevent us from making any definite statements concerning NGC 3311, but we find that the derived metallicity distribution of the IC 4051 clusters strongly depends on the assumed age distribution. Based on our most likely result that finds a large number of young/intermediate age clusters (~2 Gyr) within the selected globular cluster sample, we find metallicity peaks at ∌\sim -0.2 for the old clusters and +0.8 for the young clusters. Only few very metal poor clusters are found. However, the metallicity distribution within the young/intermediate globular cluster population is significantly affected by our choice of the applied Single Stellar Population model. The mean metallicity of the second generation of globular clusters changes from the above mentioned and extremely high +0.8 dex to +0.2 dex. Note that the model dependency becomes less severe with an increasing age of the cluster population.Comment: 21 pages, 21 figures, A&A, accepte
    • 

    corecore