21 research outputs found

    Hyaluronic Acid-Based Hydrogel Coating Does Not Affect Bone Apposition at the Implant Surface in a Rabbit Model

    No full text
    BACKGROUND: Uncemented orthopaedic implants rely on the bone-implant interface to provide stability, therefore it is essential that a coating does not interfere with the bone-forming processes occurring at the implant interface. In addition, local application of high concentrations of antibiotics for prophylaxis or treatment of infection may be toxic for osteoblasts and could impair bone growth. QUESTIONS/PURPOSES: In this animal study, we investigated the effect of a commercially available hydrogel, either unloaded or loaded with 2% vancomycin. We asked, does unloaded hydrogel or hydrogel with vancomycin (1) interfere with bone apposition and timing of bone deposition near the implant surface; and (2) induce a local or systemic inflammatory reaction as determined by inflammation around the implant and hematologic parameters. METHODS: In 18 New Zealand White rabbits, an uncoated titanium rod (n = 6), a rod coated with unloaded hydrogel (n = 6), or a rod coated with 2% vancomycin-loaded hydrogel (n = 6) was implanted in the intramedullary canal of the left tibia. After 28 days, the bone volume fraction near the implant was measured with microCT analysis, inflammation was semiquantitatively scored on histologic sections, and timing of bone apposition was followed by semiquantitative scoring of fluorochrome incorporation on histologic sections. Two observers, blinded to the treatment, scored the sections and reconciled their scores if there was a disagreement. The hematologic inflammatory reaction was analyzed by measuring total and differential leukocyte counts and erythrocyte sedimentation rates in blood. With group sizes of six animals per group, we had 79% power to detect a difference of 25% in histologic scoring for infection and inflammation. RESULTS: No differences were found in the amount of bone apposition near the implant in the No Gel group (48.65% ± 14.95%) compared with the Gel group (59.97% ± 5.02%; mean difference [MD], 11.32%; 95% CI, -3.89% to 26.53%; p = 0.16) or for the Van2 group (56.12% ± 10.06%; MD, 7.46; 95% CI, -7.75 to 22.67; p = 0.40), with the numbers available. In addition, the scores for timing of bone apposition did not differ between the No Gel group (0.50 ± 0.55) compared with the Gel group (0.33 ± 0.52; MD, -0.17; 95% CI, -0.86 to 0.53; p = 0.78) or the Van2 group (0.83 ± 0.41; MD, 0.33; 95% CI, -0.36 to 1.03; p = 0.42). Furthermore, we detected no differences in the histopathology scores for inflammation in the No Gel group (2.33 ± 1.67) compared with the Gel group (3.17 ± 1.59; MD, 0.83; 95% CI, -0.59 to 2.26; p = 0.31) or to the Van2 group (2.5 ± 1.24; MD, 0.17; 95% CI, -1.26 to 1.59; p = 0.95). Moreover, no differences in total leukocyte count, erythrocyte sedimentation rate, and neutrophil, monocyte, eosinophil, basophil, and lymphocyte counts were present between the No Gel or Van2 groups compared with the Gel control group, with the numbers available. CONCLUSION: The hydrogel coated on titanium implants, unloaded or loaded with 2% vancomycin, had no effect on the volume or timing of bone apposition near the implant, and did not induce an inflammatory reaction in vivo, with the numbers available. CLINICAL RELEVANCE: Antibiotic-loaded hydrogel may prove to be a valuable option to protect orthopaedic implants from bacterial colonization. Future clinical safety studies will need to provide more evidence that this product does not impair bone formation near the implant and prove the safety of this product

    Hyaluronic Acid-Based Hydrogel Coating Does Not Affect Bone Apposition at the Implant Surface in a Rabbit Model

    No full text
    Background: Uncemented orthopaedic implants rely on the bone-implant interface to provide stability, therefore it is essential that a coating does not interfere with the bone-forming processes occurring at the implant interface. In addition, local application of high concentrations of antibiotics for prophylaxis or treatment of infection may be toxic for osteoblasts and could impair bone growth. Questions/Purposes: In this animal study, we investigated the effect of a commercially available hydrogel, either unloaded or loaded with 2% vancomycin. We asked, does unloaded hydrogel or hydrogel with vancomycin (1) interfere with bone apposition and timing of bone deposition near the implant surface; and (2) induce a local or systemic inflammatory reaction as determined by inflammation around the implant and hematologic parameters. Methods: In 18 New Zealand White rabbits, an uncoated titanium rod (n = 6), a rod coated with unloaded hydrogel (n = 6), or a rod coated with 2% vancomycin-loaded hydrogel (n = 6) was implanted in the intramedullary canal of the left tibia. After 28 days, the bone volume fraction near the implant was measured with microCT analysis, inflammation was semiquantitatively scored on histologic sections, and timing of bone apposition was followed by semiquantitative scoring of fluorochrome incorporation on histologic sections. Two observers, blinded to the treatment, scored the sections and reconciled their scores if there was a disagreement. The hematologic inflammatory reaction was analyzed by measuring total and differential leukocyte counts and erythrocyte sedimentation rates in blood. With group sizes of six animals per group, we had 79% power to detect a difference of 25% in histologic scoring for infection and inflammation. Results: No differences were found in the amount of bone apposition near the implant in the No Gel group (48.65% ± 14.95%) compared with the Gel group (59.97% ± 5.02%; mean difference [MD], 11.32%; 95% CI, −3.89% to 26.53%; p = 0.16) or for the Van2 group (56.12% ± 10.06%; MD, 7.46; 95% CI, −7.75 to 22.67; p = 0.40), with the numbers available. In addition, the scores for timing of bone apposition did not differ between the No Gel group (0.50 ± 0.55) compared with the Gel group (0.33 ± 0.52; MD, −0.17; 95% CI, −0.86 to 0.53; p = 0.78) or the Van2 group (0.83 ± 0.41; MD, 0.33; 95% CI, −0.36 to 1.03; p = 0.42). Furthermore, we detected no differences in the histopathology scores for inflammation in the No Gel group (2.33 ± 1.67) compared with the Gel group (3.17 ± 1.59; MD, 0.83; 95% CI, −0.59 to 2.26; p = 0.31) or to the Van2 group (2.5 ± 1.24; MD, 0.17; 95% CI, −1.26 to 1.59; p = 0.95). Moreover, no differences in total leukocyte count, erythrocyte sedimentation rate, and neutrophil, monocyte, eosinophil, basophil, and lymphocyte counts were present between the No Gel or Van2 groups compared with the Gel control group, with the numbers available. Conclusion: The hydrogel coated on titanium implants, unloaded or loaded with 2% vancomycin, had no effect on the volume or timing of bone apposition near the implant, and did not induce an inflammatory reaction in vivo, with the numbers available. Clinical relevance: Antibiotic-loaded hydrogel may prove to be a valuable option to protect orthopaedic implants from bacterial colonization. Future clinical safety studies will need to provide more evidence that this product does not impair bone formation near the implant and prove the safety of this product

    Hyaluronic Acid-Based Hydrogel Coating Does Not Affect Bone Apposition at the Implant Surface in a Rabbit Model

    No full text
    BACKGROUND: Uncemented orthopaedic implants rely on the bone-implant interface to provide stability, therefore it is essential that a coating does not interfere with the bone-forming processes occurring at the implant interface. In addition, local application of high concentrations of antibiotics for prophylaxis or treatment of infection may be toxic for osteoblasts and could impair bone growth. QUESTIONS/PURPOSES: In this animal study, we investigated the effect of a commercially available hydrogel, either unloaded or loaded with 2% vancomycin. We asked, does unloaded hydrogel or hydrogel with vancomycin (1) interfere with bone apposition and timing of bone deposition near the implant surface; and (2) induce a local or systemic inflammatory reaction as determined by inflammation around the implant and hematologic parameters. METHODS: In 18 New Zealand White rabbits, an uncoated titanium rod (n = 6), a rod coated with unloaded hydrogel (n = 6), or a rod coated with 2% vancomycin-loaded hydrogel (n = 6) was implanted in the intramedullary canal of the left tibia. After 28 days, the bone volume fraction near the implant was measured with microCT analysis, inflammation was semiquantitatively scored on histologic sections, and timing of bone apposition was followed by semiquantitative scoring of fluorochrome incorporation on histologic sections. Two observers, blinded to the treatment, scored the sections and reconciled their scores if there was a disagreement. The hematologic inflammatory reaction was analyzed by measuring total and differential leukocyte counts and erythrocyte sedimentation rates in blood. With group sizes of six animals per group, we had 79% power to detect a difference of 25% in histologic scoring for infection and inflammation. RESULTS: No differences were found in the amount of bone apposition near the implant in the No Gel group (48.65% ± 14.95%) compared with the Gel group (59.97% ± 5.02%; mean difference [MD], 11.32%; 95% CI, -3.89% to 26.53%; p = 0.16) or for the Van2 group (56.12% ± 10.06%; MD, 7.46; 95% CI, -7.75 to 22.67; p = 0.40), with the numbers available. In addition, the scores for timing of bone apposition did not differ between the No Gel group (0.50 ± 0.55) compared with the Gel group (0.33 ± 0.52; MD, -0.17; 95% CI, -0.86 to 0.53; p = 0.78) or the Van2 group (0.83 ± 0.41; MD, 0.33; 95% CI, -0.36 to 1.03; p = 0.42). Furthermore, we detected no differences in the histopathology scores for inflammation in the No Gel group (2.33 ± 1.67) compared with the Gel group (3.17 ± 1.59; MD, 0.83; 95% CI, -0.59 to 2.26; p = 0.31) or to the Van2 group (2.5 ± 1.24; MD, 0.17; 95% CI, -1.26 to 1.59; p = 0.95). Moreover, no differences in total leukocyte count, erythrocyte sedimentation rate, and neutrophil, monocyte, eosinophil, basophil, and lymphocyte counts were present between the No Gel or Van2 groups compared with the Gel control group, with the numbers available. CONCLUSION: The hydrogel coated on titanium implants, unloaded or loaded with 2% vancomycin, had no effect on the volume or timing of bone apposition near the implant, and did not induce an inflammatory reaction in vivo, with the numbers available. CLINICAL RELEVANCE: Antibiotic-loaded hydrogel may prove to be a valuable option to protect orthopaedic implants from bacterial colonization. Future clinical safety studies will need to provide more evidence that this product does not impair bone formation near the implant and prove the safety of this product

    The role of bacterial stimuli in inflammation-driven bone formation

    No full text
    Immune cells and their soluble factors regulate skeletal cells during normal bone regeneration and pathological bone formation. Bacterial infections can trigger immune responses that activate pro-osteogenic pathways, but these are usually overshadowed by osteolysis and concerns of systemic inflammation. The aim of this study was to determine whether the transient local inflammatory reaction to non-viable bacterial immune agonists could lead to favourable new bone formation. In a series of rabbit studies, as proof-of-concept, how tibial intramedullary injection of viable or killed bacterial species affected bone remodelling and new bone formation was determined. Application of killed bacteria led to considerable new bone formation after 4 weeks, without the prolonged systemic inflammation and exaggerated bone lysis seen with active infection. The osteo-immunomodulatory effects of various species of killed bacteria and the dose response relationship were subsequently screened in ectopically-implanted ceramic scaffolds. Histomorphometry after 8 weeks showed that a relatively low dose of killed bacteria enhanced ectopic bone induction. Moreover, lipoteichoic acid - the bacterial cell-wall derived toll-like-receptor (TLR)-2 activator - was identified as an osteo-stimulatory factor. Collectively, the data indicated that bacterial stimuli could be harnessed to stimulate osteogenesis, which occurs through a synergy with osteoinductive signals. This finding holds promise for the use of non-viable bacteria, bacterial antigens, or their simplified analogues as immuno-modulatory bone regenerating tools in bone biomaterials

    Incidence of low-grade infection in aseptic loosening of total hip arthroplasty.

    Get PDF
    Contains fulltext : 88074.pdf (publisher's version ) (Open Access)PURPOSE: We investigated the hypothesis that many total hip arthroplasty revisions that are classified as aseptic are in fact low-grade infections missed with routine diagnostics. METHODS: In 7 Dutch hospitals, 176 consecutive patients with the preoperative diagnosis of aseptic loosening of their total hip arthroplasty were enrolled. During surgery, between 14 and 20 tissue samples were obtained for culture, pathology, and broad-range 16S rRNA PCR with reverse line blot hybridization. Patients were classified as either not being infected, suspected of having infection, or infected according to strict, predefined criteria. Each patient had a follow-up visit after 1 year. RESULTS: 7 patients were classified as infected, 4 of whom were not identified by routine culture. 15 additional patients were suspected of having infection. 20 of these 22 patients received a cemented prosthesis, fixated with antibiotic-loaded bone cement. All 22 patients received prophylactic systemic antibiotics. 7 of them reported complaints one year after surgery, but only one showed signs of early loosening. However, additional surgery was not performed in any of the patients. INTERPRETATION: Although the proportions were not as high as previously reported in the literature, between 4% and 13% of patients with the preoperative diagnosis of aseptic loosening were infected. However, as thorough debridement was performed during surgery and prophylactic antibiotics were used, the diagnosis of infection did not have any obvious clinical consequences, as most patients performed well at the 1-year follow-up. Whether this observation has implications for long-term implant survival remains to be seen.1 december 201

    Simultaneous Delivery of Multiple Antibacterial Agents from Additively Manufactured Porous Biomaterials to Fully Eradicate Planktonic and Adherent Staphylococcus aureus

    Get PDF
    Implant-associated infections are notoriously difficult to treat and may even result in amputation and death. The first few days after surgery are the most critical time to prevent those infections, preferably through full eradication of the micro-organisms entering the body perioperatively. That is particularly important for patients with a compromised immune system such as orthopedic oncology patients, as they are at higher risk for infection and complications. Full eradication of bacteria is, especially in a biofilm, extremely challenging due to the toxicity barrier that prevents delivery of high doses of antibacterial agents. This study aimed to use the potential synergistic effects of multiple antibacterial agents to prevent the use of toxic levels of these agents and achieve full eradication of planktonic and adherent bacteria. Silver ions and vancomycin were therefore simultaneously delivered from additively manufactured highly porous titanium implants with an extremely high surface area incorporating a bactericidal coating made from chitosan and gelatin applied by electrophoretic deposition (EPD). The presence of the chitosan/gelatin (Ch+Gel) coating, Ag, and vancomycin (Vanco) was confirmed by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The release of vancomycin and silver ions continued for at least 21 days as measured by inductively coupled plasma (ICP) and UV-spectroscopy. Antibacterial behavior against Staphylococcus aureus, both planktonic and in biofilm, was evaluated for up to 21 days. The Ch+Gel coating showed some bactericidal behavior on its own, while the loaded hydrogels (Ch+Gel+Ag and Ch+Gel+Vanco) achieved full eradication of both planktonic and adherent bacteria without causing significant levels of toxicity. Combining silver and vancomycin improved the release profiles of both agents and revealed a synergistic behavior that further increased the bactericidal effects

    Simultaneous delivery of multiple antibacterial agents from additively manufactured porous biomaterials to fully eradicate planktonic and adherent Staphylococcus aureus

    No full text
    Implant-associated infections are notoriously difficult to treat and may even result in amputation and death. The first few days after surgery are the most critical time to prevent those infections, preferably through full eradication of the micro-organisms entering the body perioperatively. That is particularly important for patients with a compromised immune system such as orthopedic oncology patients, as they are at higher risk for infection and complications. Full eradication of bacteria is, especially in a biofilm, extremely challenging due to the toxicity barrier that prevents delivery of high doses of antibacterial agents. This study aimed to use the potential synergistic effects of multiple antibacterial agents to prevent the use of toxic levels of these agents and achieve full eradication of planktonic and adherent bacteria. Silver ions and vancomycin were therefore simultaneously delivered from additively manufactured highly porous titanium implants with an extremely high surface area incorporating a bactericidal coating made from chitosan and gelatin applied by electrophoretic deposition (EPD). The presence of the chitosan/gelatin (Ch+Gel) coating, Ag, and vancomycin (Vanco) was confirmed by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The release of vancomycin and silver ions continued for at least 21 days as measured by inductively coupled plasma (ICP) and UV-spectroscopy. Antibacterial behavior against Staphylococcus aureus, both planktonic and in biofilm, was evaluated for up to 21 days. The Ch+Gel coating showed some bactericidal behavior on its own, while the loaded hydrogels (Ch+Gel+Ag and Ch+Gel+Vanco) achieved full eradication of both planktonic and adherent bacteria without causing significant levels of toxicity. Combining silver and vancomycin improved the release profiles of both agents and revealed a synergistic behavior that further increased the bactericidal effects.Biomaterials & Tissue Biomechanic

    The accuracy of diagnostic Imaging techniques in patients with a suspected Fracture-related Infection (IFI) trial: study protocol for a prospective multicenter cohort study

    Get PDF
    Introduction The optimal diagnostic imaging strategy for fracture-related infection (FRI) remains to be established. In this prospective study, the three commonly used advanced imaging techniques for diagnosing FRI will be compared. Primary endpoints are (1) determining the overall diagnostic performances of white blood cell (WBC) scintigraphy, fluorodeoxyglucose positron emission tomography (FDG-PET) and magnetic resonance imaging (MRI) in patients with suspected FRI and (2) establishing the most accurate imaging strategy for diagnosing FRI. Methods and analysis This study is a non-randomised, partially blinded, prospective cohort study involving two level 1 trauma centres in The Netherlands. All adult patients who require advanced medical imaging for suspected FRI are eligible for inclusion. Patients will undergo all three investigational imaging procedures (WBC scintigraphy, FDG-PET and MRI) within a time frame of 14 days after inclusion. The reference standard will be the result of at least five intraoperative sampled microbiology cultures, or, in case of no surgery, the clinical presence or absence of infection at 1 year follow-up. Initially, the results of all three imaging modalities will be available to the treating team as per local protocol. At a later time point, all scans will be centrally reassessed by nuclear medicine physicians and radiologists who are blinded for the identity of the patients and their clinical outcome. The discriminative ability of the imaging modalities will be quantified by several measures of diagnostic accuracy. Ethics and dissemination Approval of the study by the Institutional Review Board has been obtained prior to the start of this study. The results of this trial will be disseminated by publication of peer-reviewed manuscripts, presentation in abstract form at scientific meetings and data sharing with other investigators through academically established means

    Antibacterial and immunogenic behavior of silver coatings on additively manufactured porous titanium

    No full text
    Implant-associated infections (IAI) are often recurrent, expensive to treat, and associated with high rates of morbidity, if not mortality. We biofunctionalized the surface of additively manufactured volume-porous titanium implants using electrophoretic deposition (EPD) as a way to eliminate the peri-operative bacterial load and prevent IAI. Chitosan-based (Ch) coatings were incorporated with different concentrations of silver (Ag) nanoparticles or vancomycin. A full-scale in vitro and in vivo study was then performed to evaluate the antibacterial, immunogenic, and osteogenic activity of the developed implants. In vitro, Ch + vancomycin or Ch + Ag coatings completely eliminated, or reduced the number of planktonic and adherent Staphylococcus aureus by up to 4 orders of magnitude, respectively. In an in vivo tibia intramedullary implant model, Ch + Ag coatings caused no adverse immune or bone response under aseptic conditions. Following Staphylococcus aureus inoculation, Ch + vancomycin coatings reduced the implant infection rate as compared to chitosan-only coatings. Ch + Ag implants did not demonstrate antibacterial effects in vivo and even aggravated infection-mediated bone remodeling including increased osteoclast formation and inflammation-induced new bone formation. As an explanation for the poor antibacterial activity of Ch + Ag implants, it was found that antibacterial Ag concentrations were cytotoxic for neutrophils, and that non-toxic Ag concentrations diminished their phagocytic activity. This study shows the potential of EPD coating to biofunctionalize porous titanium implants with different antibacterial agents. Using this method, Ag-based coatings seem inferior to antibiotic coatings, as their adverse effects on the normal immune response could cancel the direct antibacterial effects of Ag nanoparticles. Statement of Significance: Implant-associated infections (IAI) are a clinical, societal, and economical burden. Surface biofunctionalization approaches can render complex metal implants with strong local antibacterial action. The antibacterial effects of inorganic materials such as silver nanoparticles (Ag NPs) are often highlighted under very confined conditions in vitro. As a novelty, this study also reports the antibacterial, immunogenic, and osteogenic activity of Ag NP-coated additively-manufactured titanium in vivo. Importantly, it was found that the developed coatings could impair the normal function of neutrophils, the most important phagocytic cells protecting us from IAI. Not surprisingly, the Ag NP-based coatings were outperformed by an antibiotic-based coating. This emphasizes the importance of also targeting implant immune-modulatory functions in future coating strategies against IAI
    corecore