3,995 research outputs found

    Model-Based Selection for Proton Therapy in Breast Cancer:Development of the National Indication Protocol for Proton Therapy and First Clinical Experiences

    Get PDF
    Aims: Proton therapy is a radiation technique that yields less dose in normal tissues than photon therapy. In the Netherlands, proton therapy is reimbursed if the reduced dose to normal tissues is predicted to translate into a prespecified reduction in toxicity, based on nationally approved validated models. The aim of this paper is to present the development of a national indication protocol for proton therapy (NIPP) for model-based selection of breast cancer patients and to report on first clinical experiences. Materials and methods: A national proton therapy working group for breast cancer (PWG-BC) screened the literature for prognostic models able to estimate the individual risk of specific radiation-induced side-effects. After critical appraisal and selection of suitable models, a NIPP for breast cancer was written and subjected to comments by all stakeholders. The approved NIPP was subsequently introduced to select breast cancer patients who would benefit most from proton therapy. Results: The model of Darby et al. (N Engl J Med 2013; 368:987–82) was the only model fulfilling the criteria prespecified by the PWG-BC. The model estimates the relative risk of an acute coronary event (ACE) based on the mean heart dose. The absolute lifetime risk of ACE <80 years was calculated by applying this model to the Dutch absolute incidence of ACE for female and male patients, between 40 and 70 years at breast cancer radiotherapy, with/without cardiovascular risk factors. The NIPP was approved for reimbursement in January 2019. Based on a threshold value of a 2% absolute lower risk on ACE for proton therapy compared with photons, 268 breast cancer patients have been treated in the Netherlands with proton therapy between February 2019 and January 2021. Conclusion: The NIPP includes a model that allows the estimation of the absolute risk on ACE <80 years based on mean heart dose. In the first 2 years, 268 breast cancer patients have been treated with proton therapy in The Netherlands

    Tomotherapy as a tool in image-guided radiation therapy (IGRT): current clinical experience and outcomes

    Get PDF
    Modern radiotherapy is characterised by a better target definition through medical imaging accompanied by significantly improved radiation delivery methods, most notably Intensity-Modulate Radiation Therapy (IMRT). However, the treatment can only be as accurate as the positioning of patients for their daily radiotherapy fraction. It is in this context that a number of imaging modalities - ranging from ultrasound to on-board kilovoltage imaging and computed tomography (CT) - have found their way into the treatment room where they verify accurate patient positioning prior to or even during delivery of radiation. Helical tomotherapy (HT) combines IMRT delivery with in-built image guidance using megavoltage CT scanning. This paper discusses the initial experience of different centres with IGRT using HT illustrated by a number of clinical examples from the installation in London in Ontario, Canada, one of the world’s first HT sites. We found that HT allows the delivery of highly conformal radiation dose distributions combined with adequate daily image acquisition. An important feature of this unit is its seamless integration, which also includes a customised inverse treatment planning system and a quality assurance module for individual patients

    Search for charged Higgs bosons: combined results using LEP data

    Get PDF
    The four LEP collaborations, ALEPH, DELPHI, L3 and OPAL, have searched for pair-produced charged Higgs bosons in the framework of Two Higgs Doublet Models (2HDMs). The data of the four experiments have been statistically combined. The results are interpreted within the 2HDM for Type I and Type II benchmark scenarios. No statistically significant excess has been observed when compared to the Standard Model background prediction, and the combined LEP data exclude large regions of the model parameter space. Charged Higgs bosons with mass below 80 GeV/c2 (Type II scenario) or 72.5 GeV/c2 (Type I scenario, for pseudo-scalar masses above 12 GeV/c2 ) are excluded at the 95 % confidence level

    Study of Leading Hadrons in Gluon and Quark Fragmentation

    Get PDF
    The study of quark jets in e+e- reactions at LEP has demonstrated that the hadronisation process is reproduced well by the Lund string model. However, our understanding of gluon fragmentation is less complete. In this study enriched quark and gluon jet samples of different purities are selected in three-jet events from hadronic decays of the Z collected by the DELPHI experiment in the LEP runs during 1994 and 1995. The leading systems of the two kinds of jets are defined by requiring a rapidity gap and their sum of charges is studied. An excess of leading systems with total charge zero is found for gluon jets in all cases, when compared to Monte Carlo Simulations with JETSET (with and without Bose-Einstein correlations included) and ARIADNE. The corresponding leading systems of quark jets do not exhibit such an excess. The influence of the gap size and of the gluon purity on the effect is studied and a concentration of the excess of neutral leading systems at low invariant masses (<~ 2 GeV/c^2) is observed, indicating that gluon jets might have an additional hitherto undetected fragmentation mode via a two-gluon system. This could be an indication of a possible production of gluonic states as predicted by QCD.Comment: 19 pages, 6 figures, Accepted by Phys. Lett.

    Determination of the b quark mass at the M_Z scale with the DELPHI detector at LEP

    Get PDF
    An experimental study of the normalized three-jet rate of b quark events with respect to light quarks events (light= \ell \equiv u,d,s) has been performed using the CAMBRIDGE and DURHAM jet algorithms. The data used were collected by the DELPHI experiment at LEP on the Z peak from 1994 to 2000. The results are found to agree with theoretical predictions treating mass corrections at next-to-leading order. Measurements of the b quark mass have also been performed for both the b pole mass: M_b and the b running mass: m_b(M_Z). Data are found to be better described when using the running mass. The measurement yields: m_b(M_Z) = 2.85 +/- 0.18 (stat) +/- 0.13 (exp) +/- 0.19 (had) +/- 0.12 (theo) GeV/c^2 for the CAMBRIDGE algorithm. This result is the most precise measurement of the b mass derived from a high energy process. When compared to other b mass determinations by experiments at lower energy scales, this value agrees with the prediction of Quantum Chromodynamics for the energy evolution of the running mass. The mass measurement is equivalent to a test of the flavour independence of the strong coupling constant with an accuracy of 7 permil.Comment: 24 pages, 10 figures, Accepted by Eur. Phys. J.

    Screening for psychological distress before radiotherapy for painful bone metastases may be useful to identify patients with high levels of distress

    Get PDF
    Background: Psychological distress (PD) has a major impact on quality of life. We studied the incidence of PD before and after radiotherapy for painful bone metastases. Furthermore, we aimed to identify factors predictive for PD.Methods: Between 1996 and 1998, the Dutch Bone Metastasis Study included 1157 patients with painful bone metastases. Patients were randomized between two fractionation schedules. The study showed a pain response of 74% in both groups. Patients filled out weekly questionnaires for 13 weeks, then monthly for two years. The questionnaires included a subscale for PD on the Rotterdam Symptom Checklist. We used generalized estimating equations and multivariable logistic regression analyses.Results: At baseline, 290 patients (27%) had a high level of PD. For the entire group, the level of PD remained constant over time. The majority of patients with a low level of PD at baseline remained at a low level during follow-up. In patients with a high level of PD at baseline, the mean level of PD decreased after treatment and stabilized around the cutoff level. Female patients, higher age, worse performance, lower pain score and worse self-reported QoL were associated with an increased chance of PD, although the model showed moderate discriminative power.Conclusions: A substantial proportion of patients had a high level of PD before and after radiotherapy for painful bone metastases. Most patients who reported high levels of PD when referred for palliative radiotherapy remained at high levels thereafter. Therefore, screening of PD prior to treatment seems appropriate, in order to select patients requiring intervention.</p
    corecore