433 research outputs found

    Identification of novel inhibitors of auxin-induced Ca2+ signaling via a plant-based chemical screen

    Get PDF
    Many signal perception mechanisms are connected to Ca2+-based second messenger signaling to modulate specific cellular responses. The well-characterized plant hormone auxin elicits a very rapid Ca2+ signal. However, the cellular targets of auxin-induced Ca2+ are largely unknown. Here, we screened a biologically annotated chemical library for inhibitors of auxin-induced Ca2+ entry in plant cell suspensions to better understand the molecular mechanism of auxin-induced Ca2+ and to explore the physiological relevance of Ca2+ in auxin signal transduction. Using this approach, we defined a set of diverse, small molecules that interfere with auxin-induced Ca2+ entry. Based on annotated biological activities of the hit molecules, we found that auxin-induced Ca2+ signaling is, among others, highly sensitive to disruption of membrane proton gradients and the mammalian Ca2+ channel inhibitor bepridil. Whereas protonophores nonselectively inhibited auxin-induced and osmotic-stress-induced Ca2+ signals, bepridil specifically inhibited auxin-induced Ca2+. We found evidence that bepridil severely alters vacuolar morphology and antagonized auxin-induced vacuolar remodeling. Further exploration of this plant-tailored collection of inhibitors will lead to a better understanding of auxin-induced Ca2+ entry and its relevance for auxin responses

    Use of a food frequency questionnaire in American Indian and Caucasian pregnant women: a validation study

    Get PDF
    BACKGROUND: Food frequency questionnaires (FFQs) have been validated in pregnant women, but few studies have focused specifically on low-income women and minorities. The purpose of this study was to examine the validity of the Harvard Service FFQ (HSFFQ) among low-income American Indian and Caucasian pregnant women. METHODS: The 100-item HSFFQ was administered three times to a sample of pregnant women, and two sets of 24-hour recalls (six total) were collected at approximately 12 and 28 weeks of gestation. The sample included a total of 283 pregnant women who completed Phase 1 of the study and 246 women who completed Phase 2 of the study. Deattenuated Pearson correlation coefficients were used to compare intakes of 24 nutrients estimated from the second and third FFQ to average intakes estimated from the week-12 and week-28 sets of diet recalls. RESULTS: Deattenuated correlations ranged from 0.09 (polyunsaturated fat) to 0.67 (calcium) for Phase 1 and from 0.27 (sucrose) to 0.63 (total fat) for Phase 2. Average deattenuated correlations for the two phases were 0.48 and 0.47, similar to those reported among other groups of pregnant women. CONCLUSION: The HSFFQ is a simple self-administered questionnaire that is useful in classifying low-income American Indian and Caucasian women according to relative dietary intake during pregnancy. Its use as a research tool in this population may provide important information about associations of nutrient intakes with pregnancy outcomes and may help to identify groups of women who would benefit most from nutritional interventions

    Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis

    Get PDF
    This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated and compared to commercial software. The method was applied to the sublingual microcirculation in a healthy volunteer and in a patient during cardiac surgery. Analysis time was reduced from hours to minutes compared to previous methods requiring manual vessel identification. Vessel diameter was detected with high accuracy (>80%, d > 3 pixels). Capillary length was estimated within 5 pixels accuracy. Velocity estimation was very accurate (>95%) in the range [2.5, 1,000] pixels/s. RBC velocity was reduced by 70% during the first 10 s of cardiac luxation. The present method has been shown to be fast and accurate and provides increased insight into the functional properties of the microcirculation
    • …
    corecore