A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios
The Standard Model (SM) of particle physics is both incredibly successful and
glaringly incomplete. Among the questions left open is the striking imbalance
of matter and antimatter in the observable universe which inspires experiments
to compare the fundamental properties of matter/antimatter conjugates with high
precision. Our experiments deal with direct investigations of the fundamental
properties of protons and antiprotons, performing spectroscopy in advanced
cryogenic Penning-trap systems. For instance, we compared the proton/antiproton
magnetic moments with 1.5 ppb fractional precision, which improved upon
previous best measurements by a factor of >3000. Here we report on a new
comparison of the proton/antiproton charge-to-mass ratios with a fractional
uncertainty of 16ppt. Our result is based on the combination of four
independent long term studies, recorded in a total time span of 1.5 years. We
use different measurement methods and experimental setups incorporating
different systematic effects. The final result,
= ,
is consistent with the fundamental charge-parity-time (CPT) reversal
invariance, and improves the precision of our previous best measurement by a
factor of 4.3. The measurement tests the SM at an energy scale of
GeV (CL 0.68), and improves 10 coefficients of the
Standard Model Extension (SME). Our cyclotron-clock-study also constrains
hypothetical interactions mediating violations of the clock weak equivalence
principle (WEP) for antimatter to a level of , and enables the first differential test of the WEP
using antiprotons \cite{hughes1991constraints}. From this interpretation we
constrain the differential WEP-violating coefficient to
A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, = , is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of GeV (CL 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP) for antimatter to a level of , and enables the first differential test of the WEP using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP-violating coefficient to
A 16-parts-per-trillion measurement of the antiproton-to-proton charge–mass ratio
The standard model of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe, which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning trap systems. For instance, we previously compared the proton/antiproton magnetic moments with 1.5 parts per billion fractional precision, which improved upon previous best measurements by a factor of greater than 3,000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts per trillion. Our result is based on the combination of four independent long-term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental set-ups incorporating different systematic effects. The final result, −(q/m)p/(q/m) )-p=1.000000000003(16), is consistent with the fundamental charge–parity–time reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the standard model at an energy scale of 1.96 × 10−27 gigaelectronvolts (confidence level 0.68), and improves ten coefficients of the standard model extension. Our cyclotron clock study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEPcc) for antimatter to less than 1.8 × 10−7, and enables the first differential test of the WEPcc using antiprotons. From this interpretation we constrain the differential WEPcc-violating coefficient to less than 0.030