431 research outputs found

    Computerized fetal heart rate analysis in early preterm fetal growth restriction

    Get PDF
    Objective: To assess the value of computerized cardiotocography (cCTG) with calculation of fetal heart rate (FHR) short-term variability (STV) in early preterm fetal growth restriction (FGR) for prevention of fetal death and neonatal asphyxia, neonatal morbidity, and 2-year neurodevelopmental impairment. Methods: This was a retrospective cohort study of all women who were admitted to the Amsterdam University Medical Center-AMC between 2003 and 2015 due to FGR and/or pre-eclampsia, and who were delivered by prelabor Cesarean section, or had a fetal death, before 32 weeks' gestation. STV of all available cCTG registrations during the 5 days preceding fetal death or delivery was calculated retrospectively, and FHR decelerations were classified visually as absent, 1–2/h or recurrent (> 2/h). Adverse outcome endpoints were defined as fetal death, neonatal asphyxia at birth (including fetal death), neonatal death, major neonatal morbidity and 2-year neurodevelopmental outcome. A simulation analysis was performed to assess the incidence of adverse outcome using two thresholds for cCTG: (1) highly abnormal (STV < 2.6 ms before 29 weeks and < 3.0 ms thereafter, and/or recurrent FHR decelerations); and (2) moderately abnormal (STV < 3.5 ms before 29 weeks and < 4.0 ms thereafter, and/or recurrent FHR decelerations). Three management strategies were assessed using a strict schedule for the frequency of cCTG recordings: (1) cCTG without use of fetal arterial Doppler; (2) cCTG with additional fetal arterial Doppler after 29 weeks; and (3) cCTG with additional fetal arterial Doppler after 27 weeks. Results: Included were 367 pregnancies (3295 cCTG recordings), of which 20 resulted in fetal death and 347 were delivered by Cesarean section before the onset of labor. Cesarean delivery was indicated by fetal condition in 94% of cases and by maternal condition in 6%. Median gestational age at delivery was 30 (interquartile range (IQR), 28–31) weeks and median birth weight was 900 (IQR, 740–1090) g. Six cases of fetal death were not anticipated by standard practice using visual assessment of CTG. A last highly abnormal cCTG was associated with fetal death and with neonatal asphyxia (including fetal death; n = 99), but not with major neonatal morbidity and 2-year neurodevelopmental outcome. Moderately abnormal cCTG had no significant association with any endpoint. Simulation analysis showed that a strategy that combined cCTG results with umbilicocerebral ratio or umbilical absent or reversed end-diastolic flow could detect all fetal deaths. Conclusions: Computerized CTG in combination with fetal arterial Doppler, with a strict protocol for the frequency of recordings, is likely to be more effective than visual CTG assessment for preventing fetal death in early preterm FGR

    How International, National, and Local Research Strategies Shaped ASCoR’s History in Its First 25 Years

    Get PDF
    This chapter gives an overview of the institutional development of the Amsterdam School of Communication Research (ASCoR) in the 25 years since its foundation in 1997, paying attention to both objectives of ASCoR: organising and supporting research, and training of PhD students. The chapter also discusses various factors that shaped this trajectory, including ASCoR’s orientation on media technological and societal changes, its international, funding, output, and research methods’ orientation, and individual factors. The chapter concludes with ASCoR’s new policy being deployed to address some concerns about the current research climate at universities in the Netherlands

    Diagnosis of diffuse idiopathic skeletal hyperostosis with chest computed tomography:inter-observer agreement

    Get PDF
    To evaluate and improve the interobserver agreement for the CT-based diagnosis of diffuse idiopathic skeletal hyperostosis (DISH). Six hundred participants of the CT arm of a lung cancer screening trial were randomly divided into two groups. The first 300 CTs were scored by five observers for the presence of DISH based on the original Resnick criteria for radiographs. After analysis of the data a consensus meeting was organised and the criteria were slightly modified regarding the definition of 'contiguous', the definition of 'flowing ossifications' and the viewing plane and window level. Subsequently, the second set of 300 CTs was scored by the same observers. kappa >= 0.61 was considered good agreement. The 600 male participants were on average 63.5 (SD 5.3) years old and had smoked on average 38.0 pack-years. In the first round kappa values ranged from 0.32 to 0.74 and 7 out of 10 values were below 0.61. After the consensus meeting the interobserver agreement ranged from 0.51 to 0.86 and 3 out of 10 values were below 0.61. The agreement improved significantly. This is the first study that reports interobserver agreement for the diagnosis of DISH on chest CT, showing mostly good agreement for modified Resnick criteria. . DISH is diagnosed on fluoroscopic and radiographic examinations using Resnick criteria . Evaluation of DISH on chest CT was modestly reproducible with the Resnick criteria . A consensus meeting and Resnick criteria modification improved inter-rater reliability for DISH . Reproducible CT criteria for DISH aids research into this poorly understood entity

    The impact and challenges of implementing CTCA according to the 2019 ESC guidelines on chronic coronary syndromes:a survey and projection of CTCA services in the Netherlands

    Get PDF
    BACKGROUND: The 2019 ESC-guidelines on chronic coronary syndromes (ESC-CCS) recommend computed tomographic coronary angiography (CTCA) or non-invasive functional imaging instead of exercise ECG as initial test to diagnose obstructive coronary artery disease. Since impact and challenges of these guidelines are unknown, we studied the current utilisation of CTCA-services, status of CTCA-protocols and modeled the expected impact of these guidelines in the Netherlands. METHODS AND RESULTS: A survey on current practice and CTCA utilisation was disseminated to every Dutch hospital organisation providing outpatient cardiology care and modeled the required CTCA capacity for implementation of the ESC guideline, based on these national figures and expert consensus. Survey response rate was 100% (68/68 hospital organisations). In 2019, 63 hospital organisations provided CTCA-services (93%), CTCA was performed on 99 CTCA-capable CT-scanners, and 37,283 CTCA-examinations were performed. Between the hospital organisations, we found substantial variation considering CTCA indications, CTCA equipment and acquisition and reporting standards. To fully implement the new ESC guideline, our model suggests that 70,000 additional CTCA-examinations would have to be performed in the Netherlands. CONCLUSIONS: Despite high national CTCA-services coverage in the Netherlands, a substantial increase in CTCA capacity is expected to be able to implement the 2019 ESC-CCS recommendations on the use of CTCA. Furthermore, the results of this survey highlight the importance to address variations in image acquisition and to standardise the interpretation and reporting of CTCA, as well as to establish interdisciplinary collaboration and organisational alignment

    Automatic coronary calcium scoring in chest CT using a deep neural network in direct comparison with non-contrast cardiac CT:A validation study

    Get PDF
    Purpose: To evaluate deep-learning based calcium quantification on Chest CT scans compared with manual evaluation, and to enable interpretation in terms of the traditional Agatston score on dedicated Cardiac CT. Methods: Automated calcium quantification was performed using a combination of deep-learning convolution neural networks with a ResNet-architecture for image features and a fully connected neural network for spatial coordinate features. Calcifications were identified automatically, after which the algorithm automatically excluded all non-coronary calcifications using coronary probability maps and aortic segmentation. The algorithm was first trained on cardiac-CTs and refined on non-triggered chest-CTs. This study used on 95 patients (cohort 1), who underwent both dedicated calcium scoring and chest-CT acquisitions using the Agatston score as reference standard and 168 patients (cohort 2) who underwent chest-CT only using qualitative expert assessment for external validation. Results from the deep-learning model were compared to Agatston-scores(cardiac-CTs) and manually determined calcium volumes(chest-CTs) and risk classifications. Results: In cohort 1, the Agatston score and AI determined calcium volume shows high correlation with a correlation coefficient of 0.921(p < 0.001) and R-2 of 0.91. According to the Agatston categories, a total of 67(70 %) were correctly classified with a sensitivity of 91 % and specificity of 92 % in detecting presence of coronary calcifications. Manual determined calcium volume on chest-CT showed excellent correlation with the AI volumes with a correlation coefficient of 0.923(p < 0.001) and R-2 of 0.96, no significant difference was found (p = 0.247). According to qualitative risk classifications in cohort 2, 138(82 %) cases were correctly classified with a k-coefficient of 0.74, representing good agreement. All wrongly classified scans (30(18 %)) were attributed to an adjacent category. Conclusion: Artificial intelligence based calcium quantification on chest-CTs shows good correlation compared to reference standards. Fully automating this process may reduce evaluation time and potentially optimize clinical calcium scoring without additional acquisitions

    Non-monotonic variation with salt concentration of the second virial coefficient in protein solutions

    Full text link
    The osmotic virial coefficient B2B_2 of globular protein solutions is calculated as a function of added salt concentration at fixed pH by computer simulations of the ``primitive model''. The salt and counter-ions as well as a discrete charge pattern on the protein surface are explicitly incorporated. For parameters roughly corresponding to lysozyme, we find that B2B_2 first decreases with added salt concentration up to a threshold concentration, then increases to a maximum, and then decreases again upon further raising the ionic strength. Our studies demonstrate that the existence of a discrete charge pattern on the protein surface profoundly influences the effective interactions and that non-linear Poisson Boltzmann and Derjaguin-Landau-Verwey-Overbeek (DLVO) theory fail for large ionic strength. The observed non-monotonicity of B2B_2 is compared to experiments. Implications for protein crystallization are discussed.Comment: 43 pages, including 17 figure

    Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

    Get PDF
    Purpose Assessment of calcium scoring (Ca-scoring) on a 64-slice multi-detector computed tomography (MDCT) scanner, a dual-source computed tomography (DSCT) scanner and an electron beam tomography (EBT) scanner with a moving cardiac phantom as a function of heart rate, slice thickness and calcium density. Methods and materials Three artificial arteries with inserted calcifications of different sizes and densities were scanned at rest (0 beats per minute) and at 50–110 beats per minute (bpm) with an interval of 10 bpm using 64-slice MDCT, DSCT and EBT. Images were reconstructed with a slice thickness of 0.6 and 3.0 mm. Agatston score, volume score and equivalent mass score were determined for each artery. A cardiac motion susceptibility (CMS) index was introduced to assess the susceptibility of Ca-scoring to heart rate. In addition, a difference (Δ) index was introduced to assess the difference of absolute Ca-scoring on MDCT and DSCT with EBT. Results Ca-score is relatively constant up to 60 bpm and starts to decrease or increase above 70 bpm, depending on scoring method, calcification density and slice thickness. EBT showed the least susceptibility to cardiac motion with the smallest average CMS-index (2.5). The average CMS-index of 64-slice MDCT (9.0) is approximately 2.5 times the average CMS-index of DSCT (3.6). The use of a smaller slice thickness decreases the CMS-index for both CT-modalities. The Δ-index for DSCT at 0.6 mm (53.2) is approximately 30% lower than the Δ-index for 64-slice MDCT at 0.6 mm (72.0). The Δ-indexes at 3.0 mm are approximately equal for both modalities (96.9 and 102.0 for 64-slice MDCT and DSCT respectively). Conclusion Ca-scoring is influenced by heart rate, slice thickness and modality used. Ca-scoring on DSCT is approximately 50% less susceptible to cardiac motion as 64-slice MDCT. DSCT offers a better approximation of absolute calcium score on EBT than 64-slice MDCT when using a smaller slice thickness. A smaller slice thickness reduces the susceptibility to cardiac motion and reduces the difference between CT-data and EBT-data. The best approximation of EBT on CT is found for DSCT with a slice thickness of 0.6 mm

    Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study

    Get PDF
    To assess whether absolute mass scores are comparable or differ between identical 64-slice MDCT scanners of the same manufacturer and to compare absolute mass scores to the physical mass and between scan modes using a calcified phantom. A non-moving anthropomorphic phantom with nine calcifications of three sizes and three densities was scanned 30 times on three 64-slice MDCT scanners of manufacturer A and on three 64-slice MDCT scanners of manufacturer B in both sequential and spiral scan mode. The mean mass scores and mass score variabilities of seven calcifications were determined for all scanners; two non-detectable calcifications were omitted. It was analyzed whether identical scanners yielded similar or significantly different mass scores. Furthermore mass scores were compared to the physical mass and mass scores were compared between scan modes. The mass score calibration factor was determined for all scanners. Mass scores obtained on identical scanners were similar for almost all calcifications. Overall, mass score differences between the scanners were small ranging from 1.5 to 3.4% for the total mass scores, and most differences between scanners were observed for high density calcifications. Mass scores were significantly different from the physical mass for almost all calcifications and all scanners. In sequential mode the total physical mass (167.8 mg) was significantly overestimated (+2.3%) for 4 out of 6 scanners. In spiral mode a significant overestimation (+2.5%) was found for system B and a significant underestimation (−1.8%) for two scanners of system A. Mass scores were dependent on the scan mode, for manufacturer A scores were higher in sequential mode and for manufacturer B in spiral mode. For system A using spiral scan mode no differences were found between identical scanners, whereas a few differences were found using sequential mode. For system B the scan mode did not affect the number of different mass scores between identical scanners. Mass scores obtained in the same scan mode are comparable between identical 64-slice CT scanners and identical 64-slice CT scanners on different sites can be used in follow-up studies. Furthermore, for all systems significant differences were found between mass scores and the physical calcium mass; however, the differences were relatively small and consistent
    corecore