679 research outputs found

    Gingival hyperplasia around dental implants in jaws reconstructed with free vascularized flaps: a case report series

    Get PDF
    Free vascularized flaps are the gold standard for reconstruction of the facial skeleton after surgical ablation of pathologies or when important atrophy of the jaws exists. A frequent problem seen during prosthetic rehabilitation after reconstruction with free vascularized flaps is the onset of hyperplastic granulomatous reactive tissue around the prosthetic abutment of the implant. The features of this phenomenon seem to be directly related to the characteristics of the periimplant tissue and of the manufacturing materials of the prosthesis and abutments. This complication can be seen quite often; we found it in 7 of 40 patients (17.5%). It does not seem to significantly affect the survival rate of implants. The aim of the study was to analyze the behavior of such lesions and to suggest our clinical approach with the management of these kinds of patients and complications. To remove gingival hyperplasia, we used either a traditional cold scalpel or an electric cautery or laser. We had good results using these tools. The onset of this phenomenon was not influenced by either the kind of implant and free flaps used or by the local conditions of the patients (such as radiotherapy). The number of recurrences was highly influenced by the oral hygiene of the patients

    Expanding drug resistance through integron acquisition by IncFI plasmids of Salmonella enterica Typhimurium.

    Get PDF
    We conducted a 30-year retrospective analysis of IncFI plasmids from Salmonella enterica serotype Typhimurium. These plasmids have been associated with the emergence of epidemic clones of multidrug-resistant Salmonella. Molecular and genetic evidence indicates that IncFI plasmids are evolving through sequential acquisition of integrons carrying different arrays of antibiotic- resistance genes

    Neutron sources based on medical Linac

    Get PDF
    The paper proposes the study of a novel photo-neutron source based on a medical high-energy electron Linac. Previous studies by the authors already demonstrated the possibility to obtain with this technique a thermal neutron flux of the order of 107 cm−2 s−1. This paper shows possible Linac’s setup and a new photo-converter design to reach a thermal neutron flux around 6 × 107 cm−2 s−1, keeping a reasonable high quality of the beam with respect to fast neutron and gamma contaminations

    Analysis and tests of TF magnet insulation samples for the JET upgrade to 4 tesla

    Get PDF
    The JET Toroidal Field (TF) coils were originally designed for operation at 3.4 tesla. In order to upgrade the field to 4 tesla and thus improve the performance of the JET machine, new mechanical tests and analysis were carried out on the insulation of TF coil samples. They are aimed at investigating the mechanical properties and the status of the insulation in order to set allowable stresses and force limits. In particular since the shear stress in the insulation is strongly affected by the shear modulus of elasticity G, it is important to measure this parameter. A method for the measurement of G in glass-resin fibres, the V-notched beam method (Iosipescu method) , was applied. The particular shape of the rectangular Iosipescu V- notched sample and the particular modality of force application produce pure shear stress for a reliable measurement of the G value and of the shear strength of the insulation. The effect of temperature on these mechanical properties was also investigated. Results show higher average shear strength with lower scatter compared with previous tests on conventional rectangular samples, thus confirming the reliability of the method. Micrographic analysis of the insulation and comparison between the straight and curved regions of the magnet, where the highest stress occurs, confirm the good quality of the impregnation of the coil. Glass-resin content, void content, micros and TG measurements have been performed on different samples and correlation between the different properties of the insulation investigated. Moreover fatigue tests at different temperatures were performed and data analyzed with the cumulative damage technique, which allows for an extrapolation of the fatigue curve with less samples than the standard method. (6 refs)

    Design of an epithermal column for BNCT based on D–D fusion neutron facility

    Get PDF
    Abstract Boron Neutron Capture Therapy (BNCT) is currently performed on patients at nuclear reactors. At the same time the international BNCT community is engaged in the development of alternative facilities for in-hospital treatments. This paper investigates the potential of a novel high-output D–D neutron generator, developed at Lawrence Berkeley National Laboratory (CA, USA), for BNCT. The simulation code MCNP-4C is used to realize an accurate study of the epithermal column in view of the treatment of deep tumours. Different materials and Beam Shaping Assemblies (BSA) are investigated and an optimized configuration is proposed. The neutron beam quality is defined by the standard free beam parameters, calculated averaging over the collimator aperture. The results are discussed and compared with the performances of other facilities

    Draft Genome Sequence of the Carboxydotrophic Alphaproteobacterium Aminobacter carboxidus Type Strain DSM 1086

    Get PDF
    Aminobacter carboxidus is a soil Gram-negative alphaproteobacterium belonging to the physiological group of carboxydobacteria which aerobically oxidize CO to CO2. Here, we report the draft genome sequence of the A. carboxidus DSM 1086 type strain and the identification of both form I and form II CO dehydrogenase systems in this strain

    Draft genome sequence and secondary metabolite biosynthetic potential of the lysobacter niastensis type strain DSM 18481

    Get PDF
    Lysobacter niastensis belongs to a group of bacterial predators that produce a number of bioactive small molecules endowed with lytic properties toward other microorganisms. Here, we report the draft genome sequence of the type strain DSM 18481 and the identification of gene clusters implicated in the biosynthesis of secondary metabolites

    First results with the {ANET} Compact Thermal Neutron Collimator

    Get PDF
    This paper presents the first determination of the spatial resolution of the ANET Compact Neutron Collimator, obtained with a measuring campaign at the LENA Mark-II TRIGA reactor in Pavia. This novel collimator consists of a sequence of collimating and absorbing channels organised in a chessboard-like geometry. It has a scalable structure both in length and in the field of view. It is characterized by an elevated collimation power within a limited length. Its scalability and compactness are added values with respect to traditional collimating system. The prototype tested in this article is composed of 4 concatenated stages, each 100mm long, with a channel width of 2.5mm, delivering a nominal L/D factor of 160. This measuring campaign illustrates the use of the ANET collimator and its potential application in neutron imaging for facilities with small or medium size neutron sources.Comment: 9 pages, 8 figures, prepared for submission to JINS

    Effect of pulmonary rehabilitation on heart rate recovery in adult individuals with asthma or chronic obstructive pulmonary disease

    Get PDF
    Introduction: Heart rate recovery (HRR) after exercise is a marker of disease severity and prognosis in cardiovascular and respiratory disorders. More than 30% of adult individuals with asthma may show a slow HRR. Pulmonary rehabilitation improves exercise capacity in individuals with asthma or chronic obstructive pulmonary disease (COPD). Aim: The study aimed to evaluate the effect of pulmonary rehabilitation on HRR in individuals with asthma as compared to those with COPD. Methods: Retrospective analysis of HRR one minute after the six-minute walking test (6MWT) was performed before and after an exercise training program. The COPD Assessment Test (CAT), Barthel Index-Dyspnea (BI-D), Medical Research Council (MRC) score for dyspnea, and the Five-Times-Sit-to-Stand test (5STS) were also assessed as secondary outcome measures. Results: Slow HRR prevalence was significantly lower in individuals with asthma than with COPD (29.1 vs. 46.7%, respectively: p = 0.003). Post-program HRR did not change in more than 70% of individuals in either population and improved in 16% of both populations, whereas it actually worsened in 12 and 10% of individuals with asthma and COPD, respectively. The outcome measures significantly improved in both populations, irrespective of baseline HRR. Conclusion: In individuals with asthma or COPD, exercise training does not significantly improve HRR
    • …
    corecore