    Patient-rated suitability of a novel electronic device for self-injection of subcutaneous interferon beta-1a in relapsing multiple sclerosis: an international, single-arm, multicentre, Phase IIIb study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multiple sclerosis (MS) currently requires long-term treatment with disease-modifying drugs, administered parenterally up to once daily. The need for regular self-injection can be a barrier to treatment for many patients. Autoinjectors can help patients overcome problems or concerns with self-injection and could, therefore, improve treatment adherence. This study was performed to assess the suitability of a new electronic device for the subcutaneous (sc) administration of interferon (IFN) beta-1a, 44 mcg three times weekly, for relapsing MS.</p> <p>Methods</p> <p>In this Phase IIIb, multicentre, single-arm study, patients with relapsing MS who had been consistently self-injecting sc IFN beta-1a using an autoinjector for at least 6 weeks were taught to use the new device and self-administered treatment for 12 weeks thereafter. Patient-rated suitability of the device was assessed at the end of Week 12 using the Patient User Trial Questionnaire. Patient satisfaction with, and evaluation of, the injection process was assessed using the MS Treatment Concern Questionnaire. Trainers evaluated the device using the Trainer User Trial Questionnaire.</p> <p>Results</p> <p>At Week 12, 71.6% (73/102) of patients considered the device 'very suitable' or 'suitable' for self-injection; 92.2% (94/102) reported some degree of suitability and only 7.8% (8/102) found the device 'not at all suitable'. At Weeks 4, 8 and 12, most patients reported that injection preparation and clean-up, performing injections and ease of device use in the previous 4 weeks compared favourably with, or was equivalent to, their previous experience of self-injection. Injection-related pain, injection reactions and 'flu-like' symptoms remained stable over the 12 weeks. Each device feature was rated 'very useful' or 'useful' by at least 80% of patients. All trainers and 95.2% (99/104) of patients found device functions 'very easy' or 'easy' to use. Overall convenience was considered the most important benefit of the device.</p> <p>Conclusions</p> <p>Most patients considered the new electronic injection device suitable for the sc injection of IFN beta-1a. They found the device easy to use with useful features, and reported benefits such as overall convenience. The device may, therefore, increase treatment adherence in patients with MS, particularly those with injection-related issues.</p> <p>Trial registration</p> <p>NCT00735007</p

    Effect of natalizumab on disease progression in secondary progressive multiple sclerosis (ASCEND). a phase 3, randomised, double-blind, placebo-controlled trial with an open-label extension

    Get PDF
    Background: Although several disease-modifying treatments are available for relapsing multiple sclerosis, treatment effects have been more modest in progressive multiple sclerosis and have been observed particularly in actively relapsing subgroups or those with lesion activity on imaging. We sought to assess whether natalizumab slows disease progression in secondary progressive multiple sclerosis, independent of relapses. Methods: ASCEND was a phase 3, randomised, double-blind, placebo-controlled trial (part 1) with an optional 2 year open-label extension (part 2). Enrolled patients aged 18–58 years were natalizumab-naive and had secondary progressive multiple sclerosis for 2 years or more, disability progression unrelated to relapses in the previous year, and Expanded Disability Status Scale (EDSS) scores of 3·0–6·5. In part 1, patients from 163 sites in 17 countries were randomly assigned (1:1) to receive 300 mg intravenous natalizumab or placebo every 4 weeks for 2 years. Patients were stratified by site and by EDSS score (3·0–5·5 vs 6·0–6·5). Patients completing part 1 could enrol in part 2, in which all patients received natalizumab every 4 weeks until the end of the study. Throughout both parts, patients and staff were masked to the treatment received in part 1. The primary outcome in part 1 was the proportion of patients with sustained disability progression, assessed by one or more of three measures: the EDSS, Timed 25-Foot Walk (T25FW), and 9-Hole Peg Test (9HPT). The primary outcome in part 2 was the incidence of adverse events and serious adverse events. Efficacy and safety analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01416181. Findings: Between Sept 13, 2011, and July 16, 2015, 889 patients were randomly assigned (n=440 to the natalizumab group, n=449 to the placebo group). In part 1, 195 (44%) of 439 natalizumab-treated patients and 214 (48%) of 448 placebo-treated patients had confirmed disability progression (odds ratio [OR] 0·86; 95% CI 0·66–1·13; p=0·287). No treatment effect was observed on the EDSS (OR 1·06, 95% CI 0·74–1·53; nominal p=0·753) or the T25FW (0·98, 0·74–1·30; nominal p=0·914) components of the primary outcome. However, natalizumab treatment reduced 9HPT progression (OR 0·56, 95% CI 0·40–0·80; nominal p=0·001). In part 1, 100 (22%) placebo-treated and 90 (20%) natalizumab-treated patients had serious adverse events. In part 2, 291 natalizumab-continuing patients and 274 natalizumab-naive patients received natalizumab (median follow-up 160 weeks [range 108–221]). Serious adverse events occurred in 39 (13%) patients continuing natalizumab and in 24 (9%) patients initiating natalizumab. Two deaths occurred in part 1, neither of which was considered related to study treatment. No progressive multifocal leukoencephalopathy occurred. Interpretation: Natalizumab treatment for secondary progressive multiple sclerosis did not reduce progression on the primary multicomponent disability endpoint in part 1, but it did reduce progression on its upper-limb component. Longer-term trials are needed to assess whether treatment of secondary progressive multiple sclerosis might produce benefits on additional disability components. Funding: Biogen

    Adherence to interferon β-1a therapy using an electronic self-injector in multiple sclerosis: a multicentre, single-arm, observational, phase IV study

    No full text
    Background: In a multicentre, single-arm, observational, phase IV study, we evaluated 24-week treatment adherence of relapsing multiple sclerosis (RMS) patients using an electronic auto-injection device (RebiSmart®) for subcutaneous injection of interferon (IFN) β-1a. Methods: A total of 162 adult participants with RMS were enrolled into the study to use RebiSmart® to self-administer IFN β-1a 44 μg three times weekly for a maximum of 96 weeks. The number of administered injections was recorded in the electronic device log. Adherence to treatment was defined as the administration of ≥80 % of expected injections. Cognitive impairment and injection anxiety were assessed via questionnaires. Results: Overall, 91.8 and 82.9 % of participants were adherent to treatment at weeks 12 and 24, respectively. By weeks 12 and 24, 8.2 and 13.9 % of participants had discontinued treatment. There were no statistically significant differences in adherence rates at weeks 12 and 24 according to cognitive impairment status or injection anxiety. By week 24, 69.9 % of participants were less fearful of injection than when they started the study. According to participant evaluations, the absence of a visible needle, comfort settings, and the calendar for tracking the injection schedule were all important features of the RebiSmart® injection system. At week 24, 99.3 % of participants reported that they would like to continue using RebiSmart® as their injector. Conclusions: RebiSmart® use is associated with high treatment adherence, as objectively assessed using electronic injection logs. Future research should examine if RebiSmart® use improves long-term treatment outcomes in RMS. This study was registered with ClinicalTrials.gov as NCT01128075, on May 20, 2010.Medicine, Faculty ofNon UBCMedicine, Department ofNeurology, Division ofReviewedFacult

    Adherence to interferon β-1a therapy using an electronic self-injector in multiple sclerosis: a multicentre, single-arm, observational, phase IV study

    No full text
    Abstract Background In a multicentre, single-arm, observational, phase IV study, we evaluated 24-week treatment adherence of relapsing multiple sclerosis (RMS) patients using an electronic auto-injection device (RebiSmart®) for subcutaneous injection of interferon (IFN) β-1a. Methods A total of 162 adult participants with RMS were enrolled into the study to use RebiSmart® to self-administer IFN β-1a 44 μg three times weekly for a maximum of 96 weeks. The number of administered injections was recorded in the electronic device log. Adherence to treatment was defined as the administration of ≥80 % of expected injections. Cognitive impairment and injection anxiety were assessed via questionnaires. Results Overall, 91.8 and 82.9 % of participants were adherent to treatment at weeks 12 and 24, respectively. By weeks 12 and 24, 8.2 and 13.9 % of participants had discontinued treatment. There were no statistically significant differences in adherence rates at weeks 12 and 24 according to cognitive impairment status or injection anxiety. By week 24, 69.9 % of participants were less fearful of injection than when they started the study. According to participant evaluations, the absence of a visible needle, comfort settings, and the calendar for tracking the injection schedule were all important features of the RebiSmart® injection system. At week 24, 99.3 % of participants reported that they would like to continue using RebiSmart® as their injector. Conclusions RebiSmart® use is associated with high treatment adherence, as objectively assessed using electronic injection logs. Future research should examine if RebiSmart® use improves long-term treatment outcomes in RMS. This study was registered with ClinicalTrials.gov as NCT01128075, on May 20, 2010

    Patient-rated suitability of a novel electronic device for self-injection of subcutaneous interferon beta-1a in relapsing multiple sclerosis: an international, single-arm, multicentre, Phase IIIb study

    No full text
    Background: Multiple sclerosis (MS) currently requires long-term treatment with disease-modifying drugs, administered parenterally up to once daily. The need for regular self-injection can be a barrier to treatment for many patients. Autoinjectors can help patients overcome problems or concerns with self-injection and could, therefore, improve treatment adherence. This study was performed to assess the suitability of a new electronic device for the subcutaneous (sc) administration of interferon (IFN) beta-1a, 44 mcg three times weekly, for relapsing MS. Methods: In this Phase IIIb, multicentre, single-arm study, patients with relapsing MS who had been consistently self-injecting sc IFN beta-1a using an autoinjector for at least 6 weeks were taught to use the new device and self-administered treatment for 12 weeks thereafter. Patient-rated suitability of the device was assessed at the end of Week 12 using the Patient User Trial Questionnaire. Patient satisfaction with, and evaluation of, the injection process was assessed using the MS Treatment Concern Questionnaire. Trainers evaluated the device using the Trainer User Trial Questionnaire. Results: At Week 12, 71.6% (73/102) of patients considered the device 'very suitable' or 'suitable' for self-injection; 92.2% (94/102) reported some degree of suitability and only 7.8% (8/102) found the device 'not at all suitable'. At Weeks 4, 8 and 12, most patients reported that injection preparation and clean-up, performing injections and ease of device use in the previous 4 weeks compared favourably with, or was equivalent to, their previous experience of self-injection. Injection-related pain, injection reactions and 'flu-like' symptoms remained stable over the 12 weeks. Each device feature was rated 'very useful' or 'useful' by at least 80% of patients. All trainers and 95.2% (99/104) of patients found device functions 'very easy' or 'easy' to use. Overall convenience was considered the most important benefit of the device. Conclusions: Most patients considered the new electronic injection device suitable for the sc injection of IFN beta-1a. They found the device easy to use with useful features, and reported benefits such as overall convenience. The device may, therefore, increase treatment adherence in patients with MS, particularly those with injection-related issues

    Long-Term Stability of Neuroaxonal Structure in Alemtuzumab-Treated Relapsing-Remitting Multiple Sclerosis Patients

    No full text
    Background: Patients with multiple sclerosis (MS) experience progressive thinning in optical coherence tomography (OCT) measures of neuroaxonal structure regardless of optic neuritis history. Few prospective studies have investigated the effects of disease-modifying therapies on neuroaxonal degeneration in the retina. Alemtuzumab is a monoclonal antibody shown to be superior to interferon β-1a in treating relapsing-remitting MS (RRMS). The purpose of this study was to assess the effects of alemtuzumab and first-line injectable treatments on OCT measures of neuroaxonal structure including peripapillary retinal nerve fiber layer (RNFL) thickness and combined ganglion cell-inner plexiform (GCIP) layer volume in RRMS patients followed up over 5 years. Methods: In this retrospective pilot study with prospectively collected double cohort data, spectral domain OCT measures of RNFL thickness and GCIP volume were compared between alemtuzumab-treated RRMS patients (N = 24) and RRMS patients treated with either interferon-β or glatiramer acetate (N = 21). Results: Over a median of 60 months (range 42-60 months), the alemtuzumab cohort demonstrated a change in the mean RNFL thickness (thinning from baseline) of -0.88 μm (95% confidence interval [CI] -2.63 to 0.86; P = 0.32) and mean GCIP volume of +0.013 mm (95% CI -0.006 to 0.032; P = 0.18). Over the same time period, the first-line therapy-treated cohort demonstrated greater degrees of RNFL thinning (mean change in RNFL thickness was -3.65 μm [95% CI -5.40 to -1.89; P = 0.0001]). There was also more prominent GCIP volume loss relative to baseline in the first-line therapy group (-0.052 mm [95% CI -0.070 to -0.034; P < 0.0001]). Conclusions: Alemtuzumab-treated patients with RRMS demonstrated relative stability of OCT-measured neuroaxonal structure compared with RRMS patients treated with either interferon-β or glatiramer acetate over a 5-year period. These findings, along with previous demonstration of improved brain atrophy rates, suggest that alemtuzumab may offer long-term preservation of neuroaxonal structure in patients with RRMS

    Long-Term Stability of Neuroaxonal Structure in Alemtuzumab-Treated Relapsing-Remitting Multiple Sclerosis Patients

    No full text
    Background: Patients with multiple sclerosis (MS) experience progressive thinning in optical coherence tomography (OCT) measures of neuroaxonal structure regardless of optic neuritis history. Few prospective studies have investigated the effects of disease-modifying therapies on neuroaxonal degeneration in the retina. Alemtuzumab is a monoclonal antibody shown to be superior to interferon β-1a in treating relapsing-remitting MS (RRMS). The purpose of this study was to assess the effects of alemtuzumab and first-line injectable treatments on OCT measures of neuroaxonal structure including peripapillary retinal nerve fiber layer (RNFL) thickness and combined ganglion cell-inner plexiform (GCIP) layer volume in RRMS patients followed up over 5 years. Methods: In this retrospective pilot study with prospectively collected double cohort data, spectral domain OCT measures of RNFL thickness and GCIP volume were compared between alemtuzumab-treated RRMS patients (N = 24) and RRMS patients treated with either interferon-β or glatiramer acetate (N = 21). Results: Over a median of 60 months (range 42-60 months), the alemtuzumab cohort demonstrated a change in the mean RNFL thickness (thinning from baseline) of -0.88 μm (95% confidence interval [CI] -2.63 to 0.86; P = 0.32) and mean GCIP volume of +0.013 mm (95% CI -0.006 to 0.032; P = 0.18). Over the same time period, the first-line therapy-treated cohort demonstrated greater degrees of RNFL thinning (mean change in RNFL thickness was -3.65 μm [95% CI -5.40 to -1.89; P = 0.0001]). There was also more prominent GCIP volume loss relative to baseline in the first-line therapy group (-0.052 mm [95% CI -0.070 to -0.034; P < 0.0001]). Conclusions: Alemtuzumab-treated patients with RRMS demonstrated relative stability of OCT-measured neuroaxonal structure compared with RRMS patients treated with either interferon-β or glatiramer acetate over a 5-year period. These findings, along with previous demonstration of improved brain atrophy rates, suggest that alemtuzumab may offer long-term preservation of neuroaxonal structure in patients with RRMS