11 research outputs found

    Advances in Endoscopic Visualization of Barrett’s Esophagus: The Role of Confocal Laser Endomicroscopy

    Get PDF
    Many endoscopic imaging modalities have been developed and introduced into clinical practice to enhance the diagnostic capabilities of upper endoscopy. In the past, detection of dysplasia and carcinoma of esophagus had been dependent on biopsies taken during standard white-light endoscopy (WLE). Recently high-resolution (HR) endoscopy enables us to visualize esophageal mucosa but resolution for glandular structures and cells is still low. Probe-based confocal laser endomicroscopy (pCLE) is a new promising diagnostic technique by which details of glandular and vascular structures of mucosal layer can be observed. However, the clinical utility of this new diagnostic tool has not yet been fully explored in a clinical setting. In this paper we will highlight this new technique for detection of esophageal dysplasia and carcinoma from a clinical practice perspective

    Analyses of the Post-reflux Swallow-induced Peristaltic Wave Index and Nocturnal Baseline Impedance Parameters Increase the Diagnostic Yield of Impedance-pH Monitoring of Patients With Reflux Disease

    No full text
    BACKGROUND & AIMS: Analyses of impedance parameters such as the post-reflux swallow-induced peristaltic wave (PSPW) index and the mean nocturnal baseline impedance (MNBI) have been proposed to increase the accuracy of diagnosis of reflux disease. We assessed whether these improve the diagnostic yield of impedance pH monitoring of reflux disease. METHODS: We performed a prospective study of consecutive patients with proton pump inhibitor-responsive heartburn who underwent 24-hour impedance pH monitoring at hospitals in Italy from January 2011 through December 2013. Reviewers blindly analyzed off-therapy impedance pH tracings from 289 patients with proton pump inhibitor-responsive heartburn, 68 with erosive reflux disease and 221 with non-erosive reflux disease (NERD), along with 50 healthy individuals (controls). The PSPW index, the MNBI, the esophageal acid exposure time, the number of total refluxes, and the bolus exposure were calculated, as well as the symptom association probability (SAP) and the symptom index (SI). RESULTS: In receiver operating characteristic analysis, the area under curve of the PSPW index (0.977; 95% confidence interval, 0.961-0.993) was significantly greater than that of the other impedance pH parameters in identifying patients with reflux disease (P < .001). The PSPW index and the MNBI identified patients with erosive reflux disease with the highest level of sensitivity (100% and 91%, respectively), as well as the 118 pH-positive (99% and 86%) and 103 pH-negative (77% and 56%) cases of NERD. The PSPW index and the MNBI identified pH-negative NERD with the highest level of sensitivity; values were 82% and 52% for the 65 SAP-positive and/or SI-positive cases and 68% and 63% for the 38 SAP-negative and SI-negative cases. Diagnoses of NERD were confirmed by pH-only criteria, including those that were positive on the basis of the SAP or SI, for 165 of 221 cases (75%) and by impedance pH criteria for 216 of 221 cases (98%) (P = .001). CONCLUSIONS: The PSPW index and the MNBI increase the diagnostic yield of impedance pH monitoring of patients with reflux disease. Analysis of impedance pH data by calculating the PSPW index and the MNBI can increase the accuracy of diagnosis of patients with reflux disease, compared with pH-only data

    Single balloon enteroscopy: Technical aspects and clinical applications

    No full text
    The small bowel has long been considered a black box for endoscopists because of its long length and the presence of multiple complex loop. Most of the small bowel is inaccessible by traditional endoscopic means. In addition, radiographic studies have significant limitations with regard to diagnostic yield, and surgery is an invasive alternative. This limitation was overcome through the development of balloon enteroscopy that becomes established throughout the world for diagnostic and therapeutic examinations of the small bowel. The single-balloon enteroscope (SBE) system (Olympus, Tokyo, Japan) was introduced into the commercial market in 2007. Several study demonstrated its efficacy and safety. Early reports on the use of single-balloon enteroscopy have suggested a high diagnostic yield and similar therapeutic potential to that of the double-balloon endoscope. SBE is viable technique for in the management of small bowel disease. Technically, it is easy to perform, may be efficient, and in the literature data available, seems to provide high diagnostic and therapeutic yield

    Colonic Postpolypectomy Bleeding Is Related to Polyp Size and Heparin Use

    No full text
    Background/Aims We studied factors influencing colon postpolypectomy bleeding (PPB), with a focus on antithrombotic and anticoagulation therapy. Methods We conducted a retrospective case-control study of all patients who underwent polypectomy at our tertiary referral center in Italy between 2007 and 2014. Polyp characteristics (number of polyps removed per patient, size, morphology, location, resection technique, prophylactic hemostasis methods) and patient characteristics (age, sex, comorbidities, medication) were analyzed. Results The case and control groups included 118 and 539 patients, respectively. The two groups differed in the frequency of comorbidities (69% vs. 40%, p=0.001), polyps removed (27% vs. 18%, p=0.02), and use of heparin therapy (23% vs. 1%, p<0.001). A total of 279 polyps in the case group and 966 in the control group were nonpedunculated (69% vs. 81%, p=0.01) and measured ≥10 mm (78% vs. 32%, p=0.001). Multivariate analysis showed that polyps ≥10 mm (odds ratio [OR], 6.1; 95% confidence interval [CI], 2.3–15.5), administration of heparin (OR, 16.5; 95% CI, 6.2–44), comorbidity (OR, 2.3; 95% CI, 1.4–3.9), and presence of ≥2 risk factors (OR, 3.2; 95% CI, 1.7–6.0) were associated with PPB. Conclusions The incidence of PPB increases with polyp size ≥10 mm, heparin use, comorbidity, and presence of ≥2 risk factors

    Italian Survey on Endoscopic Biliary Drainage Approach in Patients with Surgically Altered Anatomy

    No full text
    Background and Objectives: Biliary drainage (BD) in patients with surgically altered anatomy (SAA) could be obtained endoscopically with different techniques or with a percutaneous approach. Every endoscopic technique could be challenging and not clearly superior over another. The aim of this survey is to explore which is the standard BD approach in patients with SAA. Materials and Methods: A 34-question online survey was sent to different Italian tertiary and non-tertiary endoscopic centers performing interventional biliopancreatic endoscopy. The core of the survey was focused on the first-line and alternative BD approaches to SAA patients with benign or malignant obstruction. Results: Out of 70 centers, 39 answered the survey (response rate: 56%). Only 48.7% of them declared themselves to be reference centers for endoscopic BD in SAA. The total number of procedures performed per year is usually low, especially in non-tertiary centers; however, they have a low tendency to refer to more experienced centers. In the case of Billroth-II reconstruction, the majority of centers declared that they use a duodenoscope or forward-viewing scope in both benign and malignant diseases as a first approach. However, in the case of failure, the BD approach becomes extremely heterogeneous among centers without any technique prevailing over the others. Interestingly, in the case of Roux-en-Y, a significant proportion of centers declared that they choose the percutaneous approach in both benign (35.1%) and malignant obstruction (32.4%) as a first option. In the case of a previous failed attempt at BD in Roux-en-Y, the subsequent most used approach is the EUS-guided intervention in both benign and malignant indications. Conclusions: This survey shows that the endoscopic BD approach is extremely heterogeneous, especially in patients with Roux-en-Y reconstruction or after ERCP failure in Billroth-II reconstruction. Percutaneous BD is still taken into account by a significant proportion of centers in the case of Roux-en-Y anatomy. The total number of endoscopic BD procedures performed in non-tertiary centers is usually low, but this result does not correspond to an adequate rate of referral to more experienced centers

    Eus-guided gallbladder drainage as a first approach for jaundice palliation in unresectable malignant distal biliary obstruction: A prospective study

    No full text
    Background and study aim: Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in patients with distal malignant biliary obstruction (DMBO) . Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. In a palliative setting the endoscopic ultrasound gallbladder drainage (EUS-GBD) should represent an easiest and valid option. We performed a prospective study with a new EC-LAMS with the primary aim to assess the clinical success rate of EUS-GBD as first-line approach to the palliation of DMBO. Patients and methods: 37 consecutive patients undergoing EUS-GBD with a new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease &gt;15% within 24 hours and &gt;50% within 14 days after EC-LAMS placement. Results: Mean age was 73.5±10.8 years; male patients were 17 (45.9%). EC-LAMS placement was technically feasible in all of the patients (100%) and clinical success rate was 100%. 4 patient (10.8%) experienced adverse events (AEs), one bleeding, one food impaction and two cystic duct obstructions because of the disease progression. No stent-related deaths were observed. The mean of hospital stay was 7.7± 3.4 days. Median overall survival was 4 months (95% CI 1-8). Conclusions: EUS-GBD with the new EC-LAMS is a valid option in palliative endoscopic biliary drainage as first-step approach in low survival patients with malignant jaundice unfit for surgery. A smaller diameter EC-LAMS should be preferred, particularly if the drainage is performed through the stomach, to avoid potentially food impaction, which could result in stent dysfunction
    corecore