4 research outputs found

    Spanish multicenter real – life registry of retrievable vena cava filters (REFiVeC)

    Get PDF
    Background The treatment of venous thromboembolic disease the treatment of choice is systemic anticoagulation. However, the interruption of the inferior vena cava with filters has been recommended when anticoagulation fails or there is a contraindication. Due to the rising inferior vena cava filter (IVCF) complications, physicians are encouraged to retrieve them when there is no longer recommended. In daily practice, it may be a difficult close follow-up of these patients. In this study, the primary objective was to evaluate the IVCF retrieval rate of all implanted filters in a Spanish registry. Secondary objectives were to analyze the causes of failed retrieval, procedure-related complications, and outcomes at a 12-month follow-up. Results Three hundred fifty-six vena cava filters were implanted in 355 patients. The types of filter were: Gunther Tulip (Cook Medical) 160 (44.9%), Optease (Cordis) 77 (21.6%), Celect (Cook Medical) 49 (13, 7%), Aegisy (Lifetech Scientific) 33 (9.2%), Option ELITE (Argon Medical devices) 16 (4.4%), Denali filter (BD Bard) 11 (3.08%), ALN filter (ALN) 10 (2.8%). Removal was achieved in 274/356 (76,9%). eighty-two (23,1%) IVCF were not retrieved due to the following: 41 (11,5%) patients required ongoing filtration, 24 IVCF (6,7%) patients died before retrieval, and 17 (4,7%) impossibility of retrieval because of a tilted and embedded filter apex. There were no major complications observed. Conclusions The global retrieval rate of IVCF was achieved in 76.9%, and the adjusted retrieval rate was of 94.15% with no major complications. IVCF tilting was associated with failure of filter removal in less than 5% of cases. This study demonstrates that the retrieval procedure of IVCF is controlled by the clinician and not by the interventional radiologist

    The atrial fibrillation ablation pilot study: a European Survey on Methodology and results of catheter ablation for atrial fibrillation conducted by the European Heart Rhythm Association.

    No full text
    The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse how centres assess in routine clinical practice the success of the procedure and to evaluate the success rate and long-term safety/complications

    The Atrial Fibrillation Ablation Pilot Study: an European Survey on Methodology and results of catheter ablation for atrial fibrillation conducted by the European Heart Rhythm Association

    No full text
    corecore