5,212 research outputs found

    Scaling Factor Estimation Using Optimized Mass Change Strategy, Part 2: Experimental Results

    Get PDF
    The mass change method is used to estimate the scaling factors, the uncertainty is reduced when, for each mode, the frequency shift is maximized and the changes in the mode shapes are minimized, which in turn, depends on the mass change strategy chosen to modify the dynamic behavior of the structure. On the other hand, the aforementioned objectives are difficult to achieve for all modes simultaneously. Thus, a study of the number, magnitude and location of the masses must be performed previously to the modal tests. In this paper, the mass change method was applied to estimate the scaling factors of a steel cantilever beam. The effect of the mass change strategy was experimentally studied by performing several modal tests in which the magnitude, the location and the number of the attached masses were change

    Compositional analysis of excavated landfill samples and the determination of residual biogas potential of the organic fraction

    Get PDF
    The objectives of this study were to assess the biogas potential of landfilled materials and to further validate the suitability of the enzymatic hydrolysis test EHT as a valuable alternative to substitute the standardised test currently in use (BMP). Both tests were applied to a range of landfill waste samples. The waste composition and volatile solids content (VS) profile together with the BMP test results showed that the biogas potential of the waste samples was directly related to their VS content, as expected. The positive correlation between the VS and the BMP test (r = 0.67) suggests that the first could be used as a primary indicator of biogas potential of waste samples. Nevertheless, it should be validated against the BMP test because, occasionally, the VS content does not equate to the biogas production. This was mainly due to the paper content of the samples which also correlates positively (r = 0.77) with the BMP biogas production. The EHT results showed a higher correlation with the BMP test (r = 0.91) than in previous studies which used a wider mixture of enzymes containing cellulase, hemicellulase and carbohydrase. This finding positions the EHT as a quick assessing method for the biodegradability of waste samples in future sample regimes

    BIOMECHANICAL ASSESSMENT OF AERODYNAMIC RESISTANCE IN PROFFESSSIONAL CYCLISTS: METHODOLOGICAL ASPECTS

    Get PDF
    The aim of this study was to measure and compare the aerodynamic resistance (RA) in five different professional road cyclists obtained from a wind tunnel and to establish modification that into a performance improvement. Five professional cyclists from the Kelme-Costa Blanca Team were studied in five positions, four on the aerobike and one on the standard bike. From our results we conclude that establishing small modifications in the aerohandlebars, which result in a more profitable position, can reduce RA. The use of aerohelmet was not shown to be always useful. It is necessary to take into account the technique employed, corrected RA values with the anthropometric characteristics, static vs dynamic assessment when comparing professional cyclists RA

    A phase 3 multicenter, prospective, open-label efficacy and safety study of immune globulin (human) 10% caprylate/chromatography purified in patients with myasthenia gravis exacerbations

    Get PDF
    Background: Myasthenia gravis (MG) is an autoimmune disorder affecting neuromuscular transmission. Exacerbations may involve increasing bulbar weakness and/or sudden respiratory failure, both of which can be critically disabling. Management of MG exacerbations includes plasma exchange and intravenous immunoglobulin (IVIG); they are equally effective, but patients experience fewer side effects with IVIG. The objective of this study was to assess the efficacy and safety of immune globulin caprylate/chromatography purified (IGIV-C) in subjects with MG exacerbations. Methods: This prospective, open-label, non-controlled 28-day clinical trial was conducted in adults with MG Foundation of America class IVb or V status. Subjects received IGIV-C 2 g/kg over 2 consecutive days (1 g/kg/day) and were assessed for efficacy/safety on Days 7, 14, 21, and 28. The primary efficacy endpoint was the change from Baseline in quantitative MG (QMG) score to Day 14. Secondary endpoints of clinical response, Baseline to Day 14, included at least a 3-point decrease in QMG and MG Composite and a 2-point decrease in MG-activities of daily living (MG-ADL). Results: Forty-nine subjects enrolled. The change in QMG score at Day 14 was significant (p < 0.001) in the Evaluable (-6.4, n = 43) and Safety (-6.7, n = 49) populations. Among evaluable subjects, Day 14 response rates were 77, 86, and 88% for QMG, MG Composite, and MG-ADL, respectively. IGIV-C showed good tolerability with no serious adverse events. Conclusions: The results of this study show that IGIV-C was effective, safe, and well tolerated in the treatment of MG exacerbations

    Identifiability of Control-Oriented Glucose-Insulin Linear Models: Review and Analysis

    Get PDF
    One of the main challenges of glucose control in patients with type 1 diabetes is identifying a control-oriented model that reliably predicts the behavior of glycemia. Here, a review is provided emphasizing the structural identifiability and observability properties, which surprisingly reveals that few of them are globally identifiable and observable at the same time. Thus, a general proposal was developed to encompass four linear models according to suitable assumptions and transformations. After the corresponding structural properties analysis, two minimal model structures are generated, which are globally identifiable and observable. Then, the practical identifiability is analyzed for this application showing that the standard collected data in many cases do not have the necessary quality to ensure a unique solution in the identification process even when a considerable amount of data is collected. The two minimal control-oriented models were identified using a standard identification procedure using data from 30 virtual patients of the UVA/Padova simulator and 77 diabetes care data from adult patients of a diabetes center. The identification was performed in two stages: calibration and validation. In the first stage, the average length was taken as two days (dictated by the practical identifiability). For both structures, the mean absolute error was 16.8 mg/dl and 9.9 mg/dl for virtual patients and 21.6 mg/dl and 21.5 mg/dl for real patients. For the second stage, a one-day validation window was considered long enough for future artificial pancreas applications. The mean absolute error was 23.9 mg/dl and 12.3 mg/dl for virtual patients and 39.2 mg/dl and 36.6 mg/dl for virtual and real patients. These results confirm that linear models can be used as prediction models in model-based control strategies as predictive control.Fil: Hoyos, J. D.. Universidad Nacional de Colombia. Sede Medellín; ColombiaFil: Villa Tamayo, M. F.. Universidad Nacional de Colombia. Sede Medellín; ColombiaFil: Builes Montano, C. E.. Universidad de Antioquia; ColombiaFil: Ramirez Rincon, A.. Universidad Pontificia Bolivariana; ColombiaFil: Godoy, José Luis. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Garcia Tirado, J.. University of Virginia; Estados UnidosFil: Rivadeneira Paz, Pablo Santiago. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentin

    Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    Get PDF
    At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.Comment: 7 pages, 25 figures, submitted for publication in conference record of the 2011 IEEE Nuclear Science Symposium, Valencia, Spai

    An overview of the design, construction and performance of large area triple-GEM prototypes for future upgrades of the CMS forward muon system

    Get PDF
    GEM detectors are used in high energy physics experiments given their good spatial resolution, high rate capability and radiation hardness. An international collaboration is investigating the possibility of covering the 1.6 < vertical bar eta vertical bar < 2.4 region of the CMS muon endcaps with large-area triple-GEM detectors. The CMS high-eta area is actually not fully instrumented, only Cathode Strip Chamber (CSC) are installed. The vacant area presents an opportunity for a detector technology able to to cope with the harsh radiation environment; these micropattern gas detectors are an appealing option to simultaneously enhance muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study is presented. Design and construction of small (10cm x 10cm) and full-size trapezoidal (1m x 0.5m) triple-GEM prototypes is described. Results from measurements with x-rays and from test beam campaigns at the CERN SPS is shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system are reported
    corecore