1,433 research outputs found

    Accurate modelling and positioning of a magnetically-controlled catheter tip

    Get PDF
    This thesis represents the initial phase of a proposed operator and patient friendly method designed to semi-automate the positioning and directing of an intravascular catheter in the human heart using a variable electromagnetically induced field to control a catheter tip equipped with three tiny fixed magnets oriented in XYZ planes. Here we demonstrate a comprehensive mathematical model which accurately calculates the magnetic field generated by the electromagnet system, and the magnetic torques and forces exerted on a three-magnet tip catheter. From this we have developed an iterative predictive computer algorithm to show the displacement and deflection of the catheter tip. Using an eight variable power electromagnet system around a 250mm sphere of air we have proven the ability of this to accurately move the catheter tip from an initial position to a designated position within the field

    Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0

    Get PDF
    Abstract Background The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. Methods The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low HCV concentrations (</= 25 IU/mL by Roche) was tested using 107 clinical specimens. Results The 95% LoD was 5.1 IU/mL or lower for serum and 4.8 IU/mL or lower for plasma depending on the HCV genotype. The LLoQ for the assay was 10 IU/mL. Specificity was 100% with 95% confidence intervals of 99.6 to 100% for serum and plasma data combined. The assay demonstrated good linearity across the range for all genotypes. The Precision as estimated by the standard deviation (sd) was 0.17 log or lower across the range of the assay for both serum and plasma. HCV viral load results were compared using the Aptima assay and the Abbott assay giving a slope of 1.06, an intercept of 0.08 and an R2 of 0.98. HCV viral load results were compared for the Aptima and Roche assays giving a slope of 1.05, an intercept of −0.12 and an R2 of 0.96. Positive and negative agreement for the Aptima assay vs the Roche assay was 89% for low level specimens. Conclusion The Aptima assay is a highly sensitive and specific assay. The assay gave comparable HCV viral load results when compared to the Abbott and Roche assays. The performance of the Aptima assay makes it an excellent candidate for the detection and monitoring of HCV

    Appropriate Antibiotic Use and Associated Factors in Vietnamese Outpatients

    Get PDF
    Background: Inappropriate antibiotic use among outpatients is recognized as the primary driver of antibiotic resistance. A proper understanding of appropriate antibiotic usage and associated factors helps to determine and limit inappropriateness. We aimed to identify the rate of appropriate use of antibiotics and identify factors associated with the inappropriate prescriptions. Methods: We conducted a cross-sectional descriptive study in outpatient antibiotic use at a hospital in Can Tho City, Vietnam, from August 1, 2019, to January 31, 2020. Data were extracted from all outpatient prescriptions at the Medical Examination Department and analyzed by SPSS 18 and Chi-squared tests, with 95% confidence intervals. The rationale for antibiotic use was evaluated through antibiotic selection, dose, dosing frequency, dosing time, interactions between antibiotics and other drugs, and general appropriate usage. Results: A total of 420 prescriptions were 51.7% for females, 61.7% with health insurance, and 44.0% for patients with one comorbid condition. The general appropriate antibiotic usage rate was 86.7%. Prescriptions showed that 11.0% and 9.5% had a higher dosing frequency and dose than recommended, respectively; 10.2% had an inappropriate dosing time; 3.1% had drug interactions; and only 1.7% had been prescribed inappropriate antibiotics. The risk of inappropriate antibiotic use increased in patients with comorbidities and antibiotic treatment lasting >7 days (p < 0.05). Conclusions: The study indicated a need for more consideration when prescribing antibiotics to patients with comorbidities or using more than 7 days of treatment

    Algebraic charge liquids

    Get PDF
    High temperature superconductivity emerges in the cuprate compounds upon changing the electron density of an insulator in which the electron spins are antiferromagnetically ordered. A key characteristic of the superconductor is that electrons can be extracted from them at zero energy only if their momenta take one of four specific values (the `nodal points'). A central enigma has been the evolution of the zero energy electrons in the metallic state between the antiferromagnet and the superconductor, and recent experiments yield apparently contradictory results. The oscillation of the resistance in this metal as a function of magnetic field indicate that the zero energy electrons carry momenta which lie on elliptical `Fermi pockets', while ejection of electrons by high intensity light indicates that the zero energy electrons have momenta only along arc-like regions. We present a theory of new states of matter, which we call `algebraic charge liquids', which arise naturally between the antiferromagnet and the superconductor, and reconcile these observations. Our theory also explains a puzzling dependence of the density of superconducting electrons on the total electron density, and makes a number of unique predictions for future experiments.Comment: 6+8 pages, 2 figures; (v2) Rewritten for broader accessibility; (v3) corrected numerical error in Eq. (5

    3D Silicon Photonic Structures Based on Avalanche LED with Interconnections through Optical Interposer

    Get PDF
    Design and manufacturing technology of 3-D silicon photonic structures with optical interconnections through microchannel vias interposers were developed. Silicon chips placed over each other were separated by the silicon microchannel vias interposer served as a light waveguide. Light emitting diodes and photodiodes were formed at the inner surfaces of silicon chips from nanostructured silicon clusters embedded into alumina matrix. The developed structure is characterized by the current conversion efficiency of 0.1 % and can operate in the GHz frequency range

    A Survey on the Krein-von Neumann Extension, the corresponding Abstract Buckling Problem, and Weyl-Type Spectral Asymptotics for Perturbed Krein Laplacians in Nonsmooth Domains

    Full text link
    In the first (and abstract) part of this survey we prove the unitary equivalence of the inverse of the Krein--von Neumann extension (on the orthogonal complement of its kernel) of a densely defined, closed, strictly positive operator, SεIHS\geq \varepsilon I_{\mathcal{H}} for some ε>0\varepsilon >0 in a Hilbert space H\mathcal{H} to an abstract buckling problem operator. This establishes the Krein extension as a natural object in elasticity theory (in analogy to the Friedrichs extension, which found natural applications in quantum mechanics, elasticity, etc.). In the second, and principal part of this survey, we study spectral properties for HK,ΩH_{K,\Omega}, the Krein--von Neumann extension of the perturbed Laplacian Δ+V-\Delta+V (in short, the perturbed Krein Laplacian) defined on C0(Ω)C^\infty_0(\Omega), where VV is measurable, bounded and nonnegative, in a bounded open set ΩRn\Omega\subset\mathbb{R}^n belonging to a class of nonsmooth domains which contains all convex domains, along with all domains of class C1,rC^{1,r}, r>1/2r>1/2.Comment: 68 pages. arXiv admin note: extreme text overlap with arXiv:0907.144

    Understanding COVID-19 Dynamics and the Effects of Interventions in the Philippines: A Mathematical Modelling Study

    Get PDF
    Background COVID-19 initially caused less severe outbreaks in many low- and middle-income countries (LMIC) compared with many high-income countries; possibly because of differing demographics; socioeconomics; surveillance; and policy responses. Here; we investigate the role of multiple factors on COVID-19 dynamics in the Philippines; a LMIC that has had a relatively severe COVID-19 outbreak. Methods We applied an age-structured compartmental model that incorporated time-varying mobility; testing; and personal protective behaviors (through a “Minimum Health Standards” policy; MHS) to represent the first wave of the Philippines COVID-19 epidemic nationally and for three highly affected regions (Calabarzon; Central Visayas; and the National Capital Region). We estimated effects of control measures; key epidemiological parameters; and interventions. Findings Population age structure; contact rates; mobility; testing; and MHS were sufficient to explain the Philippines epidemic based on the good fit between modelled and reported cases; hospitalisations; and deaths. The model indicated that MHS reduced the probability of transmission per contact by 13-27%. The February 2021 case detection rate was estimated at ~8%; population recovered at ~9%; and scenario projections indicated high sensitivity to MHS adherence. Interpretation COVID-19 dynamics in the Philippines are driven by age; contact structure; mobility; and MHS adherence. Continued compliance with low-cost MHS should help the Philippines control the epidemic until vaccines are widely distributed; but disease resurgence may be occurring due to a combination of low population immunity and detection rates and new variants of concern
    corecore