1,161 research outputs found

    Improved red-response in thin film a-Si:H solar cells with soft-imprinted plasmonic back reflectors

    Get PDF
    The impact of controlled nanopatterning on the Ag back contact of an n-i-p a-Si:H solar cell was investigated experimentally and through electromagnetic simulation. Compared to a similar reference cell with a flat back contact, we demonstrate an efficiency increase from 4.5% to 6.2%, with a 26% increase in short circuit current density. Spectral response measurements show the majority of the improvement between 600 and 800 nm, with no reduction in photocurrent at wavelengths shorter than 600 nm. Optimization of the pattern aspect ratio using electromagnetic simulation predicts absorption enhancements over 50% at 660 nm

    Generic nano-imprint process for fabrication of nanowire arrays

    Full text link
    A generic process has been developed to grow nearly defect free arrays of (heterostructured) InP and GaP nanowires. Soft nanoimprint lithography has been used to pattern gold particle arrays on full 2 inch substrates. After lift-off organic residues remain on the surface, which induce the growth of additional undesired nanowires. We show that cleaning of the samples before growth with piranha solution in combination with a thermal anneal at 550 C for InP and 700 C for GaP results in uniform nanowire arrays with 1% variation in nanowire length, and without undesired extra nanowires. Our chemical cleaning procedure is applicable to other lithographic techniques such as e-beam lithography, and therefore represents a generic process.Comment: 12 pages, 4 figures, 2 table

    Pregnancy outcomes in asylum seekers in the North of the Netherlands:a retrospective documentary analysis

    Get PDF
    BACKGROUND: With more than 20,000 asylum seekers arriving every year, healthcare for this population has become an important issue. Pregnant asylum seekers seem to be at risk of poor pregnancy outcomes. This study aimed to assess the difference in pregnancy outcomes between asylum seekers and the local Dutch population and to identify potential substandard factors of care. METHODS: Using a retrospective study design we compared pregnancy outcomes of asylum-seeking and Dutch women who gave birth in a northern region of the Netherlands between January 2012 and December 2016. The following data were compared: perinatal mortality, maternal mortality, gestational age at delivery, preterm delivery, birth weight, small for gestational age children, APGAR score, intrauterine foetal death, mode of delivery and the need for pain medication. Cases of perinatal mortality in asylum seekers were reviewed for potential substandard factors. RESULTS: A total of 344 Asylum-seeking women and 2323 Dutch women were included. Asylum seekers had a higher rate of perinatal mortality (3.2% vs. 0.6%, p = 0.000) including a higher rate of intrauterine foetal death (2.3% vs. 0.2%, p = 0.000), higher gestational age at birth (39 + 4 vs. 38 + 6 weeks, p = 0.000), labour was less often induced (36.9 vs. 43.8, p = 0.016), postnatal hospitalization was longer (2.24 vs. 1.72 days p = 0.006) and they received more opioid analgesics (27.3% vs. 22%, p = 0.029). Babies born from asylum-seeking women had lower birth weights (3265 vs. 3385 g, p = 0.000) and were more often small for gestational age (13.9% vs. 8.4%, p = 0.002). Multivariate analysis showed that the increased risk of perinatal mortality in asylum-seeking women was independent of parity, birth weight and gestational age at birth. Review of the perinatal mortality cases in asylum seekers revealed possible substandard factors, such as late initiation of antenatal care, missed appointments because of transportation problems, not recognising alarm symptoms, not knowing who to contact and transfer to other locations during pregnancy. CONCLUSION: Pregnant asylum seekers have an increased risk of adverse pregnancy outcomes. More research is needed to identify which specific risk factors are involved in poor perinatal outcomes in asylum seekers and to identify strategies to improve perinatal care for this group of vulnerable women

    A translational rat model for ex vivo lung perfusion of pre-injured lungs after brain death

    Get PDF
    The process of brain death (BD) detrimentally affects donor lung quality. Ex vivo lung perfusion (EVLP) is a technique originally designed to evaluate marginal donor lungs. Nowadays, its potential as a treatment platform to repair damaged donor lungs is increasingly studied in experimental models. Rat models for EVLP have been described in literature before, yet the pathophysiology of BD was not included in these protocols and prolonged perfusion over 3 hours without anti-inflammatory additives was not achieved. We aimed to establish a model for prolonged EVLP of rat lungs from brain-dead donors, to provide a reliable platform for future experimental studies. Rat lungs were randomly assigned to one of four experimental groups (n = 7/group): 1) healthy, directly procured lungs, 2) lungs procured from rats subjected to 3 hours of BD and 1 hour cold storage (CS), 3) healthy, directly procured lungs subjected to 6 hours EVLP and 4), lungs procured from rats subjected to 3 hours of BD, 1 hour CS and 6 hours EVLP. Lungs from brain-dead rats showed deteriorated ventilation parameters and augmented lung damage when compared to healthy controls, in accordance with the pathophysiology of BD. Subsequent ex vivo perfusion for 6 hours was achieved, both for lungs of healthy donor rats as for pre-injured donor lungs from brain-dead rats. The worsened quality of lungs from brain-dead donors was evident during EVLP as well, as corroborated by deteriorated ventilation performance, increased lactate production and augmented inflammatory status during EVLP. In conclusion, we established a stable model for prolonged EVLP of pre-injured lungs from brain-dead donor rats. In this report we describe tips and pitfalls in the establishment of the rat EVLP model, to enhance reproducibility by other researchers

    Three Decades Single Center Experience of Airway Complications After Lung Transplantation

    Get PDF
    Post lung transplantation airway complications like necrosis, stenosis, malacia and dehiscence cause significant morbidity, and are most likely caused by post-operative hypo perfusion of the anastomosis. Treatment can be challenging, and airway stent placement can be necessary in severe cases. Risk factors for development of airway complications vary between studies. In this single center retrospective cohort study, all lung transplant recipients between November 1990 and September 2020 were analyzed and clinically relevant airway complications of the anastomosis or distal airways were identified and scored according to the ISHLT grading system. We studied potential risk factors for development of airway complications and evaluated the impact on survival. The treatment modalities were described. In 651 patients with 1,191 airway anastomoses, 63 patients developed 76 clinically relevant airway complications of the airway anastomoses or distal airways leading to an incidence of 6.4% of all anastomoses, mainly consisting of airway stenosis (67%). Development of airway complications significantly affects median survival in post lung transplant patients compared to patients without airway complication (101 months versus 136 months, p = 0.044). No significant risk factors for development of airway complication could be identified. Previously described risk factors could not be confirmed. Airway stents were required in 55% of the affected patients. Median survival is impaired by airway complications after lung transplantation. In our cohort, no significant risk factors for the development of airway complications could be identified.</jats:p&gt

    Легочная гипертензия при диастолической дисфункции левого желудочка у больных с ишемической кардиомиопатией

    Get PDF
    На основании данных эхокардиографического исследования выявлена взаимосвязь между степенью легочной гипертензии и тяжестью диастолической дисфункции левого желудочка у больных с ишемической кардиомиопатией. Показано, что рестриктиное наполнение левого желудочка наблюдается в основном при выраженной легочной гипертензии.The findings of echocardiography were used to reveal interrelation between the degree of pulmonary hypertension and severity of diastolic dysfunction of the left ventricle in patients with ischemic cardiomyopathy. Restrictive filling of the left ventricle is shown to be observed in marked pulmonary hypertension

    Optimized Spatial Correlations for Broadband Light Trapping Nanopatterns in High Efficiency Ultrathin Film a-Si:H Solar Cells

    Get PDF
    Nanophotonic structures have attracted attention for light trapping in solar cells with the potential to manage and direct light absorption on the nanoscale. While both randomly textured and nanophotonic structures have been investigated, the relationship between photocurrent and the spatial correlations of random or designed surfaces has been unclear. Here we systematically design pseudorandom arrays of nanostructures based on their power spectral density, and correlate the spatial frequencies with measured and simulated photocurrent. The integrated cell design consists of a patterned plasmonic back reflector and a nanostructured semiconductor top interface, which gives broadband and isotropic photocurrent enhancement

    Torquetenovirus Serum Load and Long-Term Outcomes in Renal Transplant Recipients

    Get PDF
    Following transplantation, patients must take immunosuppressive medication for life. Torquetenovirus (TTV) is thought to be marker for immunosuppression, and TTV-DNA levels after organ transplantation have been investigated, showing high TTV levels, associated with increased risk of infections, and low TTV levels associated with increased risk of rejection. However, this has been investigated in studies with relatively short follow-up periods. We hypothesized that TTV levels can be used to assess long term outcomes after renal transplantation. Serum samples of 666 renal transplant recipients were tested for TTV DNA. Samples were taken at least one year after renal transplantation, when TTV levels are thought to be relatively stable. Patient data was reviewed for graft failure, all-cause mortality and death due to infectious causes. Our data indicates that high TTV levels, sampled more than one year post-transplantation, are associated with all-cause mortality with a hazard ratio (HR) of 1.12 (95% CI, 1.02-1.23) per log10 increase in TTV viral load, (p = 0.02). Additionally, high TTV levels were also associated with death due to infectious causes (HR 1.20 (95% CI 1.01-1.43), p = 0.04). TTV levels decrease in the years following renal transplantation, but remain elevated longer than previously thought. This study shows that TTV level may aid in predicting long-term outcomes, all-cause mortality and death due to an infectious cause in renal transplant patients sampled over one year post-transplantation

    Is logistically motivated ex vivo lung perfusion a good idea?

    Get PDF
    Ex vivo lung perfusion (EVLP) is a technique for reconditioning and evaluating lungs. However, the use of EVLP for logistical reasons is still under discussion. In this retrospective study, all EVLPs performed between July 2012 and October 2019 were analyzed for ventilation and perfusion data. After transplantation, primary graft dysfunction (PGD), lung function, chronic lung allograft dysfunction (CLAD)-free survival, and overall survival were analyzed. Fifty EVLPs were performed: seventeen logistic EVLPs led to 15 lung transplantations (LT) and two rejections (LR), and 33 medical EVLPs resulted in 26 lung transplantations (MT) and seven rejections (MR). Pre-EVLP PaO2 was lower for MT than LT (p &lt; 0.05). Dynamic lung compliance remained stable in MT and LT but decreased in MR and LR. Plateau airway pressure started at a higher level in MR (p &lt; 0.05 MT vs. MR at T60) and increased further in LR. After transplantation, there were no differences between MT and LT in PGD, lung function, CLAD-free survival, and overall survival. In addition, the LT group was compared with a cohort group receiving standard donor lungs without EVLP (LTx). There were no significant differences between LT and LTx for PGD, CLAD-free survival, and overall survival. FVC was significantly lower in LT than in LTx after 1 year (p = 0.005). We found that LT lungs appear to perform better than MT lungs on EVLP. In turn, the outcome in the LT group was comparable with the LTx group. Overall, lung transplantation after EVLP for logistic reasons is safe and makes transplantation timing controllable.<br/
    corecore