44 research outputs found

    Optical phase coherent timing of the Crab nebula pulsar with Iqueye at the ESO New Technology Telescope

    Full text link
    The Crab nebula pulsar was observed in 2009 January and December with a novel very fast optical photon counter, Iqueye, mounted at the ESO 3.5 m New Technology Telescope. Thanks to the exquisite quality of the Iqueye data, we computed accurate phase coherent timing solutions for the two observing runs and over the entire year 2009. Our statistical uncertainty on the determination of the phase of the main pulse and the rotational period of the pulsar for short (a few days) time intervals are ≈1 μ\approx 1 \, \mus and ~0.5 ps, respectively. Comparison with the Jodrell Bank radio ephemerides shows that the optical pulse leads the radio one by ~240 μ\mus in January and ~160 μ\mus in December, in agreement with a number of other measurements performed after 1996. A third-order polynomial fit adequately describes the spin-down for the 2009 January plus December optical observations. The phase noise is consistent with being Gaussian distributed with a dispersion σ\sigma of ≈15 μ\approx 15 \, \mus in most observations, in agreement with theoretical expectations for photon noise-induced phase variability.Comment: 10 pages, 5 figures. Accepted for publication in Monthly Notices of the Royal Astronomical Societ

    Aqueye+: a new ultrafast single photon counter for optical high time resolution astrophysics

    Get PDF
    Aqueye+ is a new ultrafast optical single photon counter, based on single photon avalanche photodiodes (SPAD) and a 4-fold split-pupil concept. It is a completely revisited version of its predecessor, Aqueye, successfully mounted at the 182 cm Copernicus telescope in Asiago. Here we will present the new technological features implemented on Aqueye+, namely a state of the art timing system, a dedicated and optimized optical train, a high sensitivity and high frame rate field camera and remote control, which will give Aqueye plus much superior performances with respect to its predecessor, unparalleled by any other existing fast photometer. The instrument will host also an optical vorticity module to achieve high performance astronomical coronography and a real time acquisition of atmospheric seeing unit. The present paper describes the instrument and its first performances.Comment: Proceedings of the SPIE, Volume 9504, id. 95040C 14 pp. (2015

    Aqueye optical observations of the Crab Nebula pulsar

    Full text link
    We observed the Crab pulsar in October 2008 at the Copernico Telescope in Asiago - Cima Ekar with the optical photon counter Aqueye (the Asiago Quantum Eye) which has the best temporal resolution and accuracy ever achieved in the optical domain (hundreds of picoseconds). Our goal was to perform a detailed analysis of the optical period and phase drift of the main peak of the Crab pulsar and compare it with the Jodrell Bank ephemerides. We determined the position of the main peak using the steepest zero of the cross-correlation function between the pulsar signal and an accurate optical template. The pulsar rotational period and period derivative have been measured with great accuracy using observations covering only a 2 day time interval. The error on the period is 1.7 ps, limited only by the statistical uncertainty. Both the rotational frequency and its first derivative are in agreement with those from the Jodrell Bank radio ephemerides archive. We also found evidence of the optical peak leading the radio one by ~230 microseconds. The distribution of phase-residuals of the whole dataset is slightly wider than that of a synthetic signal generated as a sequence of pulses distributed in time with the probability proportional to the pulse shape, such as the average count rate and background level are those of the Crab pulsar observed with Aqueye. The counting statistics and quality of the data allowed us to determine the pulsar period and period derivative with great accuracy in 2 days only. The time of arrival of the optical peak of the Crab pulsar leads the radio one in agreement with what recently reported in the literature. The distribution of the phase residuals can be approximated with a Gaussian and is consistent with being completely caused by photon noise (for the best data sets).Comment: 7 pages, 7 figures. Accepted for publication in Astronomy and Astrophysic

    A Model for the Stray Light Contamination of the UVCS Instrument on SOHO

    Full text link
    We present a detailed model of stray-light suppression in the spectrometer channels of the Ultraviolet Coronagraph Spectrometer (UVCS) on the SOHO spacecraft. The control of diffracted and scattered stray light from the bright solar disk is one of the most important tasks of a coronagraph. We compute the fractions of light that diffract past the UVCS external occulter and non-specularly pass into the spectrometer slit. The diffracted component of the stray light depends on the finite aperture of the primary mirror and on its figure. The amount of non-specular scattering depends mainly on the micro-roughness of the mirror. For reasonable choices of these quantities, the modeled stray-light fraction agrees well with measurements of stray light made both in the laboratory and during the UVCS mission. The models were constructed for the bright H I Lyman alpha emission line, but they are applicable to other spectral lines as well.Comment: 19 pages, 5 figures, Solar Physics, in pres

    Thin low-gain avalanche detectors for particle therapy applications

    Get PDF
    none18The University of Torino (UniTO) and the National Institute for Nuclear Physics (INFN-TO) are investigating the use of Ultra Fast Silicon Detectors (UFSD) for beam monitoring in radiobiological experiments with therapeutic proton beams. The single particle identification approach of solid state detectors aims at increasing the sensitivity and reducing the response time of the conventional monitoring devices, based on gas detectors. Two prototype systems are being developed to count the number of beam particles and to measure the beam energy with time-of-flight (ToF) techniques. The clinically driven precision (< 1%) in the number of particles delivered and the uncertainty < 1 mm in the depth of penetration (range) in radiobiological experiments (up to 108 protons/s fluxes) are the goals to be pursued. The future translation into clinics would allow the implementation of faster and more accurate treatment modalities, nowadays prevented by the limits of state-of-the-art beam monitors. The experimental results performed with clinical proton beams at CNAO (Centro Nazionale di Adroterapia Oncologica, Pavia) and CPT (Centro di Protonterapia, Trento) showed a counting inefficiency <2% up to 100 MHz/cm2, and a deviation of few hundreds of keV of measured beam energies with respect to nominal ones. The progresses of the project are reported.noneVignati, A.; Donetti, M.; Fausti, F.; Ferrero, M.; Giordanengo, S.; Hammad Ali, O.; Mart Villarreal, O.A.; Mas Milian, F.; Mazza, G.; Monaco, V.; Sacchi, R.; Shakarami, Z.; Sola, V.; Staiano, A.; Tommasino, F.; Verroi, E.; Wheadon, R.; Cirio, R.Vignati, A.; Donetti, M.; Fausti, F.; Ferrero, M.; Giordanengo, S.; Hammad Ali, O.; Mart Villarreal, O. A.; Mas Milian, F.; Mazza, G.; Monaco, V.; Sacchi, R.; Shakarami, Z.; Sola, V.; Staiano, A.; Tommasino, F.; Verroi, E.; Wheadon, R.; Cirio, R

    The optical light curve of the LMC pulsar B0540-69 in 2009

    Full text link
    This paper reports a detailed analysis of the optical light curve of PSR B0540-69, the second brightest pulsar in the visible band, obtained in 2009 (Jan. 18 and 20, and Dec. 14, 15, 16, 18) with the very high speed photon counting photometer Iqueye mounted at the ESO 3.6-m NTT in La Silla (Chile). The optical light curve derived by Iqueye shows a double structure in the main peak, with a raising edge steeper than the trailing edge. The double peak can be fitted by two Gaussians with the same height and FWHM of 13.3 and 15.5 ms respectively. Our new values of spin frequencies allow to extend by 3.5 years the time interval over which a reliable estimate of frequency first and second derivatives can be performed. A discussion of implications on the braking index and age of the pulsar is carried out. A value of n = 2.087 +/- 0.007 for the overall braking index from 1987 to 2009 is derived. The braking index corrected age is confirmed around 1700 years.Comment: Accepted for publication in MNRA

    Interacting supernovae and supernova impostors. LSQ13zm: an outburst heralds the death of a massive star

    Get PDF
    We report photometric and spectroscopic observations of the optical transient LSQ13zm. Historical data reveal the presence of an eruptive episode (that we label as ‘2013a’) followed by a much brighter outburst (‘2013b’) three weeks later, that we argue to be the genuine supernova explosion. This sequence of events closely resemble those observed for SN 2010mc and (in 2012) SN 2009ip. The absolute magnitude reached by LSQ13zm during 2013a (MR = ?14.87 ± 0.25?mag) is comparable with those of supernova impostors, while that of the 2013b event (MR = ?18.46 ± 0.21?mag) is consistent with those of interacting supernovae. Our spectra reveal the presence of a dense and structured circumstellar medium, probably produced through numerous pre-supernova mass-loss events. In addition, we find evidence for high-velocity ejecta, with a fraction of gas expelled at more than 20 000?km s?1. The spectra of LSQ13zm show remarkable similarity with those of well-studied core-collapse supernovae. From the analysis of the available photometric and spectroscopic data, we conclude that we first observed the last event of an eruptive sequence from a massive star, likely a Luminous Blue Variable, which a short time later exploded as a core-collapse supernova. The detailed analysis of archival images suggest that the host galaxy is a star-forming Blue Dwarf Compact Galaxy

    Interacting supernovae and supernova impostors. LSQ13zm: An outburst heralds the death of a massive star

    Get PDF
    © 2016 The Authors.We report photometric and spectroscopic observations of the optical transient LSQ13zm. Historical data reveal the presence of an eruptive episode (that we label as '2013a') followed by a much brighter outburst ('2013b') three weeks later, that we argue to be the genuine supernova explosion. This sequence of events closely resemble those observed for SN 2010mc and (in 2012) SN 2009ip. The absolute magnitude reached by LSQ13zm during 2013a (MR = -14.87 ± 0.25mag) is comparable with those of supernova impostors, while that of the 2013b event (MR = -18.46 ± 0.21mag) is consistent with those of interacting supernovae. Our spectra reveal the presence of a dense and structured circumstellar medium, probably produced through numerous pre-supernova mass-loss events. In addition, we find evidence for high-velocity ejecta, with a fraction of gas expelled at more than 20 000km s-1. The spectra of LSQ13zm show remarkable similarity with those of well-studied core-collapse supernovae. From the analysis of the available photometric and spectroscopic data, we conclude that we first observed the last event of an eruptive sequence from a massive star, likely a Luminous Blue Variable, which a short time later exploded as a core-collapse supernova. The detailed analysis of archival images suggest that the host galaxy is a star-forming Blue Dwarf Compact Galaxy

    Analysis of diffraction from the occulter edges of a giant externally occulted solar coronagraph

    No full text
    A technique is described for the calculation of the intensity of the light diffracted by the occulter of an externally occulted solar coronagraph. This technique can be applied to an occulter of generic shape, but the attention is here focused on a specific application; that is, the case of a giant space solar coronagraph, in which the occulter is located at 100 m from the telescope aperture. By means of the code developed, it has been possible to simulate the effects of various shapes of the occulter edge with the aim of analyzing in detail the best apodization for the coronagraph. The results obtained show that an occulter with a circular serrated edge allows a remarkable reduction of the amount of diffracted light on the coronagraph’s entrance aperture with respect to a simpler circular disk case
    corecore