91 research outputs found

    Macrotidal beach monitoring (Belgium) using hypertemporal terrestrial lidar

    Get PDF
    Macrotidal Beach Monitoring (Belgium) using Hypertemporal Terrestrial Lidar Greet DERUYTER, Lars De SLOOVER, Jeffrey VERBEURGT, Alain DE WULF, Belgium and Sander VOS, the NetherlandsKey words: Continuous Terrestrial Laser Scanning, Coastal Monitoring, Beach Mapping, North SeaSUMMARY In order to protect the Belgian coast, knowledge on natural sand dynamics is essential. Monitoring sand dynamics is commonly done through sediment budget analysis, which relies on determining the volumes of sediment added or removed from the coastal system. These volumetrics require precise and accurate 3D data of the terrain on different time stamps. Earlier research states the potential of permanent long-range terrestrial laser scanning for continuous monitoring of coastal dynamics. For this paper, this methodology wasimplemented at an ultradissipative macrotidal North Sea beach in Mariakerke (Ostend, Belgium). A Riegl VZ-2000 LiDAR, mounted on a 42 m high building, scanned the intertidal and dry beach in a test zone of ca. 200 m wide on an hourly basis over a time period of one year.It appeared that the laser scanner could notbe assumed to have a fixed zenith for each hourly scan. The scanner compensator measured a variable deviation of the Z-axis of more than 3.00 mrad. This resultedin a deviation of ca. 900 mm near the low water line. A robust calibration procedure was developed to correct the deviations of the Z-axis. In this paper, we start by presenting the first results achieved with the current methodology. Next, we analyze the results from a 10-day measurement campaignand highlight the tide-dominated beach morphology

    Macrotidal beach monitoring (Belgium) using hypertemporal terrestrial lidar

    Get PDF
    Macrotidal Beach Monitoring (Belgium) using Hypertemporal Terrestrial Lidar Greet DERUYTER, Lars De SLOOVER, Jeffrey VERBEURGT, Alain DE WULF, Belgium and Sander VOS, the NetherlandsKey words: Continuous Terrestrial Laser Scanning, Coastal Monitoring, Beach Mapping, North SeaSUMMARY In order to protect the Belgian coast, knowledge on natural sand dynamics is essential. Monitoring sand dynamics is commonly done through sediment budget analysis, which relies on determining the volumes of sediment added or removed from the coastal system. These volumetrics require precise and accurate 3D data of the terrain on different time stamps. Earlier research states the potential of permanent long-range terrestrial laser scanning for continuous monitoring of coastal dynamics. For this paper, this methodology wasimplemented at an ultradissipative macrotidal North Sea beach in Mariakerke (Ostend, Belgium). A Riegl VZ-2000 LiDAR, mounted on a 42 m high building, scanned the intertidal and dry beach in a test zone of ca. 200 m wide on an hourly basis over a time period of one year.It appeared that the laser scanner could notbe assumed to have a fixed zenith for each hourly scan. The scanner compensator measured a variable deviation of the Z-axis of more than 3.00 mrad. This resultedin a deviation of ca. 900 mm near the low water line. A robust calibration procedure was developed to correct the deviations of the Z-axis. In this paper, we start by presenting the first results achieved with the current methodology. Next, we analyze the results from a 10-day measurement campaignand highlight the tide-dominated beach morphology

    Assessment of handheld mobile terrestrial laser scanning for estimating tree parameters

    Get PDF
    Sustainable forest management heavily relies on the accurate estimation of tree parameters. Among others, the diameter at breast height (DBH) is important for extracting the volume and mass of an individual tree. For systematically estimating the volume of entire plots, airborne laser scanning (ALS) data are used. The estimation model is frequently calibrated using manual DBH measurements or static terrestrial laser scans (STLS) of sample plots. Although reliable, this method is time-consuming, which greatly hampers its use. Here, a handheld mobile terrestrial laser scanning (HMTLS) was demonstrated to be a useful alternative technique to precisely and efficiently calculate DBH. Different data acquisition techniques were applied at a sample plot, then the resulting parameters were comparatively analysed. The calculated DBH values were comparable to the manual measurements for HMTLS, STLS, and ALS data sets. Given the comparability of the extracted parameters, with a reduced point density of HTMLS compared to STLS data, and the reasonable increase of performance, with a reduction of acquisition time with a factor of 5 compared to conventional STLS techniques and a factor of 3 compared to manual measurements, HMTLS is considered a useful alternative technique

    GNSS interferometric reflectometry for station location suitability analysis

    Get PDF
    National geodetic reference systems can be continuously monitored using applications of Global Navigation Satellite Systems (GNSS). Within these reference systems, Continuously Operating GNSS Reference Stations (CORSs) are often employed to provide 24/7 satellite tracking data. Understanding the influence of the surroundings of a CORS on the recorded satellite tracking data is indispensable for quality analysis of both acquired data and station location suitability. One of the main sources of inaccurate tracking data is the result of the combined reception of direct as well as indirect, environment-reflected satellite signals by the CORS, in which the latter can be considered interference compromising the signal’s accuracy. The magnitude of this interference is usually evaluated by the Signal-to-Noise Ratio (SNR), a parameter stored by default in the RINEX interchange format for raw GNSS data. The technique of GNSS Interferometric Reflectometry (GNSS-IR) exploits the availability of the SNR data and has been frequently used for applications such as soil moisture monitoring, detection of vegetation water content, measuring snowfall or determining water levels. In this research, we propose to employ GNSS-IR to investigate the effect of the surrounding on a CORS in order to evaluate station location suitability. More specifically, this will be done by using the signal to estimate the Reflector Height (RH), which depends on the reflector roughness (i.e. the roughness of the surface surrounding the CORS). The quality of this estimation will be validated by comparing with the actual measurement of the RH of the CORS on site. In our approach, a statistically sound method is developed quantifying the stability of the RH determination. The proposed methodology consists of using Lomb-Scargle periodograms to select the dominant oscillation frequency of each satellite track SNR data, followed by an analysis and filtering of the peak amplitudes. This leads to the analysis product: number of significant peak amplitudes for an individual CORS over (sub-)daily timeframes. With historical data covering long time periods, statistical analysis of the (sub-)daily timeseries allows for reviewing the station location suitability. In Belgium, CORS are located on two typical positions: in Flanders, the 32 antennas are mainly installed on rooftops of buildings; in Wallonia, the 23 antennas are installed on a concrete pole next to highways. There is no evidence of one choice of station position being more suitable than the other. However, cars are known to be an important factor in signal reflections. In our analysis of station suitability, the effect of cars passing by on the highway near a Walloon CORS, but also movements on, e.g., parking lots next to buildings with a rooftop CORS, will be investigated. With the developed methodology, guidelines for station location selection could be further developed, together with a system to continuously monitor CORS position suitability using GNSS-IR, triggering a warning when significant changes in the environment changes the local reflectometry fingerprint

    A review of the internet of floods : near real-time detection of a flood event and its impact

    Get PDF
    Worldwide, flood events frequently have a dramatic impact on urban societies. Time is key during a flood event in order to evacuate vulnerable people at risk, minimize the socio-economic, ecologic and cultural impact of the event and restore a society from this hazard as quickly as possible. Therefore, detecting a flood in near real-time and assessing the risks relating to these flood events on the fly is of great importance. Therefore, there is a need to search for the optimal way to collect data in order to detect floods in real time. Internet of Things (IoT) is the ideal method to bring together data of sensing equipment or identifying tools with networking and processing capabilities, allow them to communicate with one another and with other devices and services over the Internet to accomplish the detection of floods in near real-time. The main objective of this paper is to report on the current state of research on the IoT in the domain of flood detection. Current trends in IoT are identified, and academic literature is examined. The integration of IoT would greatly enhance disaster management and, therefore, will be of greater importance into the future

    ROMS based hydrodynamic modelling focusing on the Belgian part of the southern North Sea

    Get PDF
    The North Sea is a shallow sea that forms a complex physical system. The nonlinear interaction of the astronomical tides, varying wind fields and varying pressure systems requires appropriate approaches to be described accurately. An application based on the advanced numerical model Regional Ocean Modeling System (ROMS) was newly developed by the authors, tailored to simulate these hydrodynamic processes in the North Sea and the Belgian Continental Shelf, which is the area of particular interest in the present study. The purpose of this work is to develop and validate a state-of-the-art three-dimensional numerical model to form the basis of a compound operational and forecasting tool for the Belgian coastal zone. The model was validated with respect to water levels and temperature. Validation for astronomical tides was accomplished through the comparison of the principal constituents between the model results and observations at a number of tidal gauges in Belgium and other countries. A statistical analysis of the results showed that the model behaves as expected throughout the North Sea. The model response to the varying meteorological conditions was also validated using hindcast data for 2011 as input. In this case, the comparison between observed and modelled water levels showed a good agreement with average RMSE in Belgium 9.5 cm. Overall, the added value of this work is the development of an independent model for validation and comparison with other models and which can be used as an efficient tool for operational and forecasting purposes

    Measuring surface moisture on a sandy beach based on corrected intensity data of a mobile terrestrial LiDAR

    Get PDF
    Surface moisture plays a key role in limiting the aeolian transport on sandy beaches. However, the existing measurement techniques cannot adequately characterize the spatial and temporal distribution of the beach surface moisture. In this study, a mobile terrestrial LiDAR (MTL) is demonstrated as a promising method to detect the beach surface moisture using a phase-based Z&F/Leica HDS6100 laser scanner mounted on an all-terrain vehicle. Firstly, two sets of indoor calibration experiments were conducted so as to comprehensively investigate the effect of distance, incidence angle and sand moisture contents on the backscattered intensity by means of sand samples with an average grain diameter of 0.12 mm. A moisture estimation model was developed which eliminated the effects of the incidence angle and distance (it only relates to the target surface reflectance). The experimental results reveal both the distance and incidence angle influencing the backscattered intensity of the sand samples. The standard error of the moisture model amounts to 2.0% moisture, which is considerably lower than the results of the photographic method. Moreover, a field measurement was conducted using the MTL system on a sandy beach in Belgium. The accuracy and robustness of the beach surface moisture derived from the MTL data was evaluated. The results show that the MTL is a highly suitable technique to accurately and robustly measure the surface moisture variations on a sandy beach with an ultra-high spatial resolution (centimeter-level) in a short time span (12 x 200 m per minute)

    Post Mining Ground Deformations Transition Related to Coal Mines Closure in the Campine Coal Basin, Belgium, Evidenced by Three Decades of MT-InSAR Data

    Full text link
    peer reviewedSpatio-temporal ground-movement measurements and mappings have been carried out in the Campine coalfield in Belgian Limburg since the closure of the mines to document post-mining effects. MT-InSAR measurements are compared to groundwater head changes in the overburden and to height data from the closest GNSS stations. Radar interferometry is used to estimate the extension and the velocity of ground movements. In particular, the MT-InSAR technique has been applied to SAR acquisitions of the satellites ERS-1/2 (1991–2005), ENVISAT (2003–2010), COSMO-SkyMed (2011–2014), and Sentinel-1A (2014–2022). The images were processed and used to highlight a switch from subsidence to uplift conditions in the western part of the coal basin, while the eastern part had already been affected by a rebound since the beginning of the ERS-1/2 acquisitions. Following the closure of the last active colliery of Zolder in 1992 and the subsequent cease of mine-water pumping, a recharge of mine-water aquifers occurred in the western part of the basin. This process provoked the change from subsidence to uplift conditions that was recorded during the ENVISAT period. In the center of the coal-mining area, measured uplift velocities reached a maximum of 18 mm/year during the ENVISAT period, while they subsided at -12 mm/year during the ERS-1/2 period. Mean velocities in the western and eastern parts of the coalfield area have decreased since the last MT-InSAR measurements were performed using Sentinel-1A, while the Zolder coal mine continues to rise at a faster-than-average rate of a maximum of 16 mm/year. The eastern part of the coalfield is still uplifting, while its rate has been reduced from 18 mm/year (ERS-1/2) to 9 mm/year (Sentinel-1A) since the beginning of the radar–satellite observations. Time-series data from the two GNSS stations present in the study area were used for a local comparison with the evolution of ground movements observed by MT-InSAR. Two leveling campaigns (2000, 2013) were also used to make comparisons with the MT-InSAR data. The station’s measurements and the leveling data were in line with the MT-InSAR data. Overall, major ground movements are obviously limited to an extension of the actual underground-mining works and rapidly diminish outside of them

    Quantitative measurement of odor detection thresholds using an air dilution olfactometer, and association with genetic variants in a sample of diverse ancestry

    Get PDF
    Genetic association studies require a quantitative and reliable method for odor threshold assessment in order to examine the contribution of genetic variants to complex olfactory phenotypes. Our main goal was to assess the feasibility of a portable Scentroid air dilution olfactometer for use in such studies. Using the Scentroid SM110C and the SK5 n-butanol Sensitivity Kit (IDES Canada Inc.), n-butanol odor thresholds were determined for 182 individuals of diverse ancestry (mean age: 20.4 ± 2.5 years; n = 128 female; n = 54 male). Threshold scores from repeat participants were used to calculate a test–retest reliability coefficient, which was statistically significant (r = 0.754, p < 0.001, n = 29), indicating that the Scentroid provides reliable estimates of odor thresholds. In addition, we performed a preliminary genetic analysis evaluating the potential association of n-butanol odor thresholds to six single-nucleotide polymorphisms (SNPs) putatively involved in general olfactory sensitivity (GOS). The results of multiple linear regression analysis revealed no significant association between the SNPs tested and threshold scores. However, our sample size was relatively small, and our study was only powered to identify genetic markers with strong effects on olfactory sensitivity. Overall, we find that the Scentroid provides reliable quantitative measures of odor detection threshold and is well suited for genetic studies of olfactory sensitivity
    • …
    corecore