78 research outputs found

    The impact of signal-to-noise ratio, diffusion-weighted directions and image resolution in cardiac diffusion tensor imaging - insights from the ex-vivo rat heart

    Get PDF
    Background: Cardiac diffusion tensor imaging (DTI) is limited by scan time and signal-to-noise (SNR) restrictions. This invariably leads to a trade-off between the number of averages, diffusion-weighted directions (ND), and image resolution. Systematic evaluation of these parameters is therefore important for adoption of cardiac DTI in clinical routine where time is a key constraint. Methods: High quality reference DTI data were acquired in five ex-vivo rat hearts. We then retrospectively set 2 ≤ SNR ≤ 97, 7 ≤ ND ≤ 61, varied the voxel volume by up to 192-fold and investigated the impact on the accuracy and precision of commonly derived parameters. Results: For maximal scan efficiency, the accuracy and precision of the mean diffusivity is optimised when SNR is maximised at the expense of ND. With typical parameter settings used clinically, we estimate that fractional anisotropy may be overestimated by up to 13% with an uncertainty of ±30%, while the precision of the sheetlet angles may be as poor as ±31°. Although the helix angle has better precision of ±14°, the transmural range of helix angles may be under-estimated by up to 30° in apical and basal slices, due to partial volume and tapering myocardial geometry. Conclusions: These findings inform a baseline of understanding upon which further issues inherent to in-vivo cardiac DTI, such as motion, strain and perfusion, can be considered. Furthermore, the reported bias and reproducibility provides a context in which to assess cardiac DTI biomarkers

    More Evidence that Depressive Symptoms Predict Mortality in COPD Patients: Is Type D Personality an Alternative Explanation?

    Get PDF
    The present study attempted to replicate our previous finding that depressive symptoms are a risk factor for mortality in stable chronic obstructive pulmonary disease (COPD), but in a different population with a different measure of depressive symptoms. We further investigated whether type D personality is associated with mortality in patients with COPD and whether it explains any relationship observed between depressive symptoms and mortality. In 122 COPD patients, mean age 60.8 +/- 10.3 years, 52% female, and mean forced expiratory volume in 1 s (FEV(1)) 41.1 +/- 17.6%pred, we assessed body mass index, post bronchodilator FEV(1), exercise capacity, depressive symptoms with the Hospital Anxiety and Depression Scale, and type D with the Type D Scale. In the 7 years follow-up, 48 (39%) deaths occurred. The median survival time was 5.3 years. Depressive symptoms (hazard ratio = 1.07, 95% confidence intervals = 1.00-1.14) were an independent risk factor for mortality. Type D was not associated with mortality. We can rule out type D as an explanation for the relationship between depressive symptoms and mortality observed in this sample. However, ambiguity remains as to the interpretation of the value of depressive symptoms in predicting death

    Comparison of diffusion tensor imaging by cardiovascular magnetic resonance and gadolinium enhanced 3D image intensity approaches to investigation of structural anisotropy in explanted rat hearts

    Get PDF
    Background: Cardiovascular magnetic resonance (CMR) can through the two methods 3D FLASH and diffusion tensor imaging (DTI) give complementary information on the local orientations of cardiomyocytes and their laminar arrays. Methods: Eight explanted rat hearts were perfused with Gd-DTPA contrast agent and fixative and imaged in a 9.4T magnet by two types of acquisition: 3D fast low angle shot (FLASH) imaging, voxels 50 × 50 × 50 μm, and 3D spin echo DTI with monopolar diffusion gradients of 3.6 ms duration at 11.5 ms separation, voxels 200 × 200 × 200 μm. The sensitivity of each approach to imaging parameters was explored. Results:The FLASH data showed laminar alignments of voxels with high signal, in keeping with the presumed predominance of contrast in the interstices between sheetlets. It was analysed, using structure-tensor (ST) analysis, to determine the most (v 1 ST ), intermediate (v 2 ST ) and least (v 3 ST ) extended orthogonal directions of signal continuity. The DTI data was analysed to determine the most (e 1 DTI ), intermediate (e 2 DTI ) and least (e 3 DTI ) orthogonal eigenvectors of extent of diffusion. The correspondence between the FLASH and DTI methods was measured and appraised. The most extended direction of FLASH signal (v 1 ST ) agreed well with that of diffusion (e 1 DTI ) throughout the left ventricle (representative discrepancy in the septum of 13.3 ± 6.7°: median ± absolute deviation) and both were in keeping with the expected local orientations of the long-axis of cardiomyocytes. However, the orientation of the least directions of FLASH signal continuity (v 3 ST ) and diffusion (e 3 ST ) showed greater discrepancies of up to 27.9 ± 17.4°. Both FLASH (v 3 ST ) and DTI (e 3 DTI ) where compared to directly measured laminar arrays in the FLASH images. For FLASH the discrepancy between the structure-tensor calculated v 3 ST and the directly measured FLASH laminar array normal was of 9 ± 7° for the lateral wall and 7 ± 9° for the septum (median ± inter quartile range), and for DTI the discrepancy between the calculated v 3 DTI and the directly measured FLASH laminar array normal was 22 ± 14° and 61 ± 53.4°. DTI was relatively insensitive to the number of diffusion directions and to time up to 72 hours post fixation, but was moderately affected by b-value (which was scaled by modifying diffusion gradient pulse strength with fixed gradient pulse separation). Optimal DTI parameters were b = 1000 mm/s2 and 12 diffusion directions. FLASH acquisitions were relatively insensitive to the image processing parameters explored. Conclusions: We show that ST analysis of FLASH is a useful and accurate tool in the measurement of cardiac microstructure. While both FLASH and the DTI approaches appear promising for mapping of the alignments of myocytes throughout myocardium, marked discrepancies between the cross myocyte anisotropies deduced from each method call for consideration of their respective limitations

    Physical activity and risk of Metabolic Syndrome in an urban Mexican cohort

    Get PDF
    Abstract Background In the Mexican population metabolic syndrome (MS) is highly prevalent. It is well documented that regular physical activity (PA) prevents coronary diseases, type 2 diabetes and MS. Most studies of PA have focused on moderate-vigorous leisure-time activity, because it involves higher energy expenditures, increase physical fitness, and decrease the risk of MS. However, for most people it is difficult to get a significant amount of PA from only moderately-vigorous leisure activity, so workplace activity may be an option for working populations, because, although may not be as vigorous in terms of cardio-respiratory efforts, it comprises a considerable proportion of the total daily activity with important energy expenditure. Since studies have also documented that different types and intensity of daily PA, including low-intensity, seem to confer important health benefits such as prevent MS, we sought to assess the impact of different amounts of leisure-time and workplace activities, including low-intensity level on MS prevention, in a sample of urban Mexican adults. Methods The study population consisted of 5118 employees and their relatives, aged 20 to 70 years, who were enrolled in the baseline evaluation of a cohort study. MS was assessed according to the criteria of the National Cholesterol Education Program, ATP III and physical activity with a validated self-administered questionnaire. Associations between physical activity and MS risk were assessed with multivariate logistic regression models. Results The prevalence of the components of MS in the study population were: high glucose levels 14.2%, high triglycerides 40.9%, high blood pressure 20.4%, greater than healthful waist circumference 43.2% and low-high density lipoprotein 76.9%. The prevalence of MS was 24.4%; 25.3% in men and 21.8% in women. MS risk was reduced among men (OR 0.72; 95%CI 0.57–0.95) and women (OR 0.78; 95%CI 0.64–0.94) who reported an amount of ≥30 minutes/day of leisure-time activity, and among women who reported an amount of ≥3 hours/day of workplace activity (OR 0.75; 95%CI 0.59–0.96). Conclusion Our results indicate that both leisure-time and workplace activity at different intensity levels, including low-intensity significantly reduce the risk of MS. This finding highlights the need for more recommendations regarding the specific amount and intensity of leisure-time and workplace activity needed to prevent MS

    Multi-resolution transverse oscillation in ultrasound imaging for motion estimation

    No full text
    International audienceBeyond all recent methods for estimating multidimensional motion vectors in ultrasound (US) image sequences, the transverse oscillation (TO) images coupled with a phase-based motion estimator has shown to be an extremely promising approach. To improve existing TO techniques, this paper proposes a multi-resolution transverse oscillation (MRTO) that measures the motion in US image sequences at different resolutions. Several TO images are created using harmonic images obtained from nonlinear US propagation or from composite emissions. Motion estimations are made with increasing resolution levels, i.e., decreasing transverse wavelength, to improve the previous measurements. When only lateral motion is applied to the tissue, the resulting estimations, quantitatively assessed in both simulations and in vitro experiments, are significantly improved in terms of mean motion error and standard deviation. With a 1-mm displacement in the chirp transmission, the error is reduced from 40.9% to 0.1% in the simulation and from 41.6% to 1.5% in the experiment. The first quasi-static elastography results, in simulation and experimentation, also confirm this improvement with an increased contrast-to-noise ratio and signal-to-noise ratio

    Simulation of nonlinear ultrasound wave propagation in Fourier domain

    No full text
    International audienceThe nonlinear ultrasound field distortion occurs in all biological media and reminds of great interest in all nonlinear imaging strategies as harmonic or contrast agent imaging. From the various set of methods that compute this propagation, the angular spectrum one is the fastest in term of computation time but the harmonics calculation is less accurate compared to other strategies. In this work, a new formulation based on a slowly varying envelope approximation is proposed to evaluate the full nonlinear spectrum distortion during the propagation. This tool is compared to a previous published angular method and the resulting pressure fields are very close which validate the proposed strategy, with a maximal error inferior to 2 dB. In term of computation time, the proposed tools is as fast as the previous one, but compute the full spectrum in once
    corecore