168 research outputs found

    Cavity-QED tests of representations of canonical commutation relations employed in field quantization

    Full text link
    Various aspects of dissipative and nondissipative decoherence of Rabi oscillations are discussed in the context of field quantization in alternative representations of CCR. Theory is confronted with experiment, and a possibility of more conclusive tests is analyzed.Comment: Discussion of dissipative and nondissipative decoherence is included. Theory is now consistent with the existing data and predictions for new experiments are more reliabl

    Radiation-grafted anion-exchange membranes for CO2 electroreduction cells: an unexpected effect of using a lower excess of N-methylpiperidine in their fabrication

    Get PDF
    Giron Rodriguez et al. [ACS Sustainable Chem. Eng., 2023, 11, 1508] previously showed that radiation-grafted anion-exchange membranes containing N-benzyl-N-methylpiperidinium headgroups (MPIP-RG-AEM) are promising for use in CO2 electrolysis (cf. commercial and other RG-AEM types). For a more sustainable synthesis, MPIP-RG-AEMs have now been fabricated using a reduced 1.1 times excess of amine reagent (historically made using >5 times excess). A resulting RG-AEM promisingly had a bulk amination level that was comparable to those made with the traditional large excess. Unexpectedly, however, it had a significantly reduced water content, with two further batches showing that this observation was repeatable (and reproducible via measurements collected on a single batch using different techniques in different labs). The ionic conductivities of the RG-AEM made with a controlled 1.1 excess of amine were also lower, with higher activation energies. Terahertz time-domain spectroscopy measurements showed that the lower water uptake RG-AEMs, made with the 1.1 amine excess, contained smaller amounts of bulk water relative to bound water (a repeatable observation with different counter-anions). This lack of bulk water, yielding reduced water diffusion coefficients, led to a change in the water management when such RG-AEMs were tested in CO2 electrolysis cells, with significantly affected in situ performances. Small angle scattering data (X-ray and neutron) indicated that MPIP-RG-AEM fabrication with the 1.1 excess of amine reduced the size of the amorphous lamella domains on hydration, and this change is suspected to be the cause of the lower water uptakes and swelling. The finding that chemically similar AEMs can have significantly different hydration properties is potentially important to all ion-exchange membrane users and developers (beyond the CO2 electrolysis scope of this study)

    A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain

    Get PDF
    Background: Magnetocardiography (MCG) is a non-invasive technique used to measure and map cardiac magnetic fields. We describe the predictive performance of a portable prototype magnetometer designed for use in acute and routine clinical settings. We assessed the predictive ability of the measurements derived from the magnetometer for the ruling-out of healthy subjects and patients whose chest pain has a non-ischemic origin from those with ischemic heart disease (IHD). Methods: MCG data were analyzed from a technical performance study, a pilot clinical study, and a young healthy reference group. Participants were grouped to enable differentiation of those with IHD versus non-IHD versus controls: Group A (70 IHD patients); Group B (69 controls); Group C (37 young healthy volunteers). Scans were recorded in an unshielded room. Between-group differences were explored using analysis of variance. The ability of 10 candidate MCG predictors to predict normal/abnormal cases was analyzed using logistic regression. Predictive performance was internally validated using repeated five-fold cross-validation. Results: Three MCG predictors showed a significant difference between patients and age-matched controls (P<0.001); eight predictors showed a significant difference between patients and young healthy volunteers (P<0.001). Logistic regression comparing patients with controls yielded a specificity of 35.0%, sensitivity of 95.4%, and negative predictive value for the ruling-out of IHD of 97.8% (area under the curve 0.78). Conclusion: This analysis represents a preliminary indication that the portable magnetometer can help rule-out healthy subjects and patients whose chest pain has a non-ischemic origin from those with IHD

    Characterisation of the maternal response to chronic phase shifts during gestation in the rat: implications for fetal metabolic programming

    Get PDF
    Disrupting maternal circadian rhythms through exposure to chronic phase shifts of the photoperiod has lifelong consequences for the metabolic homeostasis of the fetus, such that offspring develop increased adiposity, hyperinsulinaemia and poor glucose and insulin tolerance. In an attempt to determine the mechanisms by which these poor metabolic outcomes arise, we investigated the impact of chronic phase shifts (CPS) on maternal and fetal hormonal, metabolic and circadian rhythms. We assessed weight gain and food consumption of dams exposed to either CPS or control lighting conditions throughout gestation. At day 20, dams were assessed for plasma hormone and metabolite concentrations and glucose and insulin tolerance. Additionally, the expression of a range of circadian and metabolic genes was assessed in maternal, placental and fetal tissue. Control and CPS dams consumed the same amount of food, yet CPS dams gained 70% less weight during the first week of gestation. At day 20, CPS dams had reduced retroperitoneal fat pad weight (−15%), and time-of-day dependent decreases in liver weight, whereas fetal and placental weight was not affected. Melatonin secretion was not altered, yet the timing of corticosterone, leptin, glucose, insulin, free fatty acids, triglycerides and cholesterol concentrations were profoundly disrupted. The expression of gluconeogenic and circadian clock genes in maternal and fetal liver became either arrhythmic or were in antiphase to the controls. These results demonstrate that disruptions of the photoperiod can severely disrupt normal circadian profiles of plasma hormones and metabolites, as well as gene expression in maternal and fetal tissues. Disruptions in the timing of food consumption and the downstream metabolic processes required to utilise that food, may lead to reduced efficiency of growth such that maternal weight gain is reduced during early embryonic development. It is these perturbations that may contribute to the programming of poor metabolic homeostasis in the offspring.Tamara J. Varcoe, Michael J. Boden, Athena Voultsios, Mark D. Salkeld, Leewen Rattanatray, David J. Kennawa

    To what extent do nurses use research in clinical practice? A systematic review

    Get PDF
    Background : In the past forty years, many gains have been made in our understanding of the concept of research utilization. While numerous studies exist on professional nurses\u27 use of research in practice, no attempt has been made to systematically evaluate and synthesize this body of literature with respect to the extent to which nurses use research in their clinical practice. The objective of this study was to systematically identify and analyze the available evidence related to the extent to which nurses use research findings in practice. Methods : This study was a systematic review of published and grey literature. The search strategy included 13 online bibliographic databases: Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, MEDLINE, CINAHL, EMBASE, HAPI, Web of Science, SCOPUS, OCLC Papers First, OCLC WorldCat, ABI Inform, Sociological Abstracts, and Dissertation Abstracts. The inclusion criteria consisted of primary research reports that assess professional nurses\u27 use of research in practice, written in the English or Scandinavian languages. Extent of research use was determined by assigning research use scores reported in each article to one of four quartiles: low, moderate-low, moderate-high, or high. Results : Following removal of duplicate citations, a total of 12,418 titles were identified through database searches, of which 133 articles were retrieved. Of the articles retrieved, 55 satisfied the inclusion criteria. The 55 final reports included cross-sectional/survey (n = 51) and quasi-experimental (n = 4) designs. A sensitivity analysis, comparing findings from all reports with those rated moderate (moderate-weak and moderate-strong) and strong quality, did not show significant differences. In a majority of the articles identified (n = 38, 69%), nurses reported moderate-high research use. Conclusions : According to this review, nurses\u27 reported use of research is moderate-high and has remained relatively consistent over time until the early 2000\u27s. This finding, however, may paint an overly optimistic picture of the extent to which nurses use research in their practice given the methodological problems inherent in the majority of studies. There is a clear need for the development of standard measures of research use and robust well-designed studies examining nurses\u27 use of research and its impact on patient outcomes. The relatively unchanged self-reports of moderate-high research use by nurses is troubling given that over 40 years have elapsed since the first studies in this review were conducted and the increasing emphasis in the past 15 years on evidence-based practice. More troubling is the absence of studies in which attempts are made to assess the effects of varying levels of research use on patient outcomes.<br /

    Study protocol for the translating research in elder care (TREC): building context – an organizational monitoring program in long-term care project (project one)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>While there is a growing awareness of the importance of organizational context (or the work environment/setting) to successful knowledge translation, and successful knowledge translation to better patient, provider (staff), and system outcomes, little empirical evidence supports these assumptions. Further, little is known about the factors that enhance knowledge translation and better outcomes in residential long-term care facilities, where care has been shown to be suboptimal. The project described in this protocol is one of the two main projects of the larger five-year Translating Research in Elder Care (TREC) program.</p> <p>Aims</p> <p>The purpose of this project is to establish the magnitude of the effect of organizational context on knowledge translation, and subsequently on resident, staff (unregulated, regulated, and managerial) and system outcomes in long-term care facilities in the three Canadian Prairie Provinces (Alberta, Saskatchewan, Manitoba).</p> <p>Methods/Design</p> <p>This study protocol describes the details of a multi-level – including provinces, regions, facilities, units within facilities, and individuals who receive care (residents) or work (staff) in facilities – and longitudinal (five-year) research project. A stratified random sample of 36 residential long-term care facilities (30 urban and 6 rural) from the Canadian Prairie Provinces will comprise the sample. Caregivers and care managers within these facilities will be asked to complete the TREC survey – a suite of survey instruments designed to assess organizational context and related factors hypothesized to be important to successful knowledge translation and to achieving better resident, staff, and system outcomes. Facility and unit level data will be collected using standardized data collection forms, and resident outcomes using the Resident Assessment Instrument-Minimum Data Set version 2.0 instrument. A variety of analytic techniques will be employed including descriptive analyses, psychometric analyses, multi-level modeling, and mixed-method analyses.</p> <p>Discussion</p> <p>Three key challenging areas associated with conducting this project are discussed: sampling, participant recruitment, and sample retention; survey administration (with unregulated caregivers); and the provision of a stable set of study definitions to guide the project.</p

    A systematic review of the psychometric properties of self-report research utilization measures used in healthcare

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In healthcare, a gap exists between what is known from research and what is practiced. Understanding this gap depends upon our ability to robustly measure research utilization.</p> <p>Objectives</p> <p>The objectives of this systematic review were: to identify self-report measures of research utilization used in healthcare, and to assess the psychometric properties (acceptability, reliability, and validity) of these measures.</p> <p>Methods</p> <p>We conducted a systematic review of literature reporting use or development of self-report research utilization measures. Our search included: multiple databases, ancestry searches, and a hand search. Acceptability was assessed by examining time to complete the measure and missing data rates. Our approach to reliability and validity assessment followed that outlined in the <it>Standards for Educational and Psychological Testing</it>.</p> <p>Results</p> <p>Of 42,770 titles screened, 97 original studies (108 articles) were included in this review. The 97 studies reported on the use or development of 60 unique self-report research utilization measures. Seven of the measures were assessed in more than one study. Study samples consisted of healthcare providers (92 studies) and healthcare decision makers (5 studies). No studies reported data on acceptability of the measures. Reliability was reported in 32 (33%) of the studies, representing 13 of the 60 measures. Internal consistency (Cronbach's Alpha) reliability was reported in 31 studies; values exceeded 0.70 in 29 studies. Test-retest reliability was reported in 3 studies with Pearson's <it>r </it>coefficients > 0.80. No validity information was reported for 12 of the 60 measures. The remaining 48 measures were classified into a three-level validity hierarchy according to the number of validity sources reported in 50% or more of the studies using the measure. Level one measures (n = 6) reported evidence from any three (out of four possible) <it>Standards </it>validity sources (which, in the case of single item measures, was all applicable validity sources). Level two measures (n = 16) had evidence from any two validity sources, and level three measures (n = 26) from only one validity source.</p> <p>Conclusions</p> <p>This review reveals significant underdevelopment in the measurement of research utilization. Substantial methodological advances with respect to construct clarity, use of research utilization and related theory, use of measurement theory, and psychometric assessment are required. Also needed are improved reporting practices and the adoption of a more contemporary view of validity (<it>i.e.</it>, the <it>Standards</it>) in future research utilization measurement studies.</p

    IEC data for paper "Separation of carbon dioxide with a low temperature electrochemical anion exchange membrane"

    No full text
    Cl- anion titrations on alkaline ionomer poweders with aqueous silver nitrate using Metrohm 848 AutotitratorsRaw data for ion-exchange capacities (IEC) for radiation-grafted alkaline ionomer powders used in the | Version: 1.

    Investigations of the ex situ ionic conductivities at 30 degrees C of metal-cation-free quaternary ammonium alkaline anion-exchange membranes in static atmospheres of different relative humidities

    No full text
    This article presents the first systematic study of the effect of Relative Humidity (RH) on the water content and hydroxide ion conductivity of quaternary ammonium-based Alkaline Anion-Exchange Membranes (AAEMs). These AAEMs have been developed specifically for application in alkaline membrane fuel cells, where conductivities of >0.01 S cm−1 are mandatory. When fully hydrated, an ETFE-based radiation-grafted AAEM exhibited a hydroxide ion conductivity of 0.030 ± 0.005 S cm−1 at 30 °C without additional incorporation of metal hydroxide salts; this is contrary to the previous wisdom that anion-exchange membranes are very low in ionic conductivity and represents a significant breakthrough for metal-cation-free alkaline ionomers. Desirably, this AAEM also showed increased dimensional stability on full hydration compared to a Nafion®-115 proton-exchange membrane; this dimensional stability is further improved (with no concomitant reduction in ionic conductivity) with a commercial AAEM of similar density but containing additional cross-linking. However, all of the AAEMs evaluated in this study demonstrated unacceptably low conductivities when the humidity of the surrounding static atmospheres was reduced (RH = 33–91%); this highlights the requirement for continued AAEM development for operation in H2/air fuel cells with low humidity gas supplies. Preliminary investigations indicate that the activation energies for OH− conduction in these quaternary ammonium-based solid polymer electrolytes are typically 2–3 times higher than for H+ conduction in acidic Nafion®-115 at all humidities
    • …
    corecore