26 research outputs found

    Advantages, disadvantages and feasibility of Pay-for-Quality programs in Belgium

    Get PDF
    Advantages, disadvantages and feasibility of the introduction of ‘Pay for Quality’ programmes in Belgiu

    Electron Trapping in GaN-on-Si Power HEMTs:Impact of Positive Substrate Bias

    Get PDF
    none10sinoneUren, M. J.; Caesar, M.; Karboyan, S.; Chatterjee, I.; Meneghini, M.; Meneghesso, G.; Zanoni, E.; Moens, P.; Vanmeerbeek, P.; Kuball, M.Uren, M. J.; Caesar, M.; Karboyan, S.; Chatterjee, I.; Meneghini, Matteo; Meneghesso, Gaudenzio; Zanoni, Enrico; Moens, P.; Vanmeerbeek, P.; Kuball, M

    Ellenberg-type indicator values for European vascular plant species

    Get PDF
    Aims: Ellenberg-type indicator values are expert-based rankings of plant species according to their ecological optima on main environmental gradients. Here we extend the indicator-value system proposed by Heinz Ellenberg and co-authors for Central Europe by incorporating other systems of Ellenberg-type indicator values (i.e., those using scales compatible with Ellenberg values) developed for other European regions. Our aim is to create a harmonized data set of Ellenberg-type indicator values applicable at the European scale. Methods: We collected European data sets of indicator values for vascular plants and selected 13 data sets that used the nine-, ten- or twelve-degree scales defined by Ellenberg for light, temperature, moisture, reaction, nutrients and salinity. We compared these values with the original Ellenberg values and used those that showed consistent trends in regression slope and coefficient of determination. We calculated the average value for each combination of species and indicator values from these data sets. Based on species’ co-occurrences in European vegetation plots, we also calculated new values for species that were not assigned an indicator value. Results: We provide a new data set of Ellenberg-type indicator values for 8908 European vascular plant species (8168 for light, 7400 for temperature, 8030 for moisture, 7282 for reaction, 7193 for nutrients, and 7507 for salinity), of which 398 species have been newly assigned to at least one indicator value. Conclusions: The newly introduced indicator values are compatible with the original Ellenberg values. They can be used for large-scale studies of the European flora and vegetation or for gap-filling in regional data sets. The European indicator values and the original and taxonomically harmonized regional data sets of Ellenberg-type indicator values are available in the Supporting Information and the Zenodo repository

    Microleakage and Resin-to-Dentin Interface Morphology of Pre-Etching versus Self-Etching Adhesive Systems

    Get PDF
    The purpose of this study was to compare the microleakage and tissue-adhesive interface morphology from Class V restorations using different systems of dentin adhesives. Class V cavities were prepared on buccal surfaces of 27 extracted caries-free molars and premolars. Teeth were randomly assigned to one of three groups: (1) Prime & Bond NT, a 5th generation system using an initial step of total etch followed by a second step of application of a self bonding primer (2) Clearfil SE Bond, a 5th generation adhesive system employing two separate steps of self-etch priming and subsequent bonding (3) One-up Bond F, a 6th generation one step self-etching, self-priming and self-bonding adhesive. Microleakage and interface morphology of teeth restored with these adhesives and a composite resin were evaluated. Kruskal-Wallis Test (p = 0.05) was used to analyze the results. SEM analysis was used to relate interface morphology to microleakage. The mean and (SD) values of microleakage were: Prime and Bond NT: 0.15 (0.33), Clearfil SE Bond: 0.06 (0.17) and One-up Bond F: 2.96 (0.63). The mean microleakage for One-up Bond was significantly higher than for the other groups (p<0.05). Protruding tags in dentin channels were observed in Prime and Bond and Clearfil systems, but not in One-up Bond. The single step adhesive system, although more convenient for the clinician, uses a low viscosity formulation difficult to keep in place on cavity walls. It also tends to be too aggressive and hydrophilic to create an impermeable hybridized tissue-adhesive interfacial layer resistant to microleakage. Two-step adhesive systems, on the other hand, were retained on all segments of the cavosurface during application, and formed a hybridized interfacial layer resistant to microleakage

    The Vienna self-assessment questionnaire: a usable tool towards more health-literate hospitals? Explorative case studies in three hospitals in Belgium

    No full text
    BackgroundStrengthening the capacity of hospitals to take into account the level of health literacy of their public is a necessity to improve the quality of care. One way to develop adequate health literacy responsive policy and strategies in hospitals is the use of self-assessment tools to raise awareness, help prioritise action and mobilise stakeholders. The Vienna Health Literate Organisation (V-HLO) questionnaire, recently translated and adapted into French, is designed to meet this objective. In this study we have piloted the French version of the V-HLO (V-HLO-fr) tool in the main hospitals of Liege (Belgium) to explore its feasibility and gain a first insight into the strengths and weaknesses of the health literacy responsiveness of the participating hospitals.MethodsWe performed explorative case studies in three hospitals. Our mode of application of the V-HLO-fr was inspired by the 'RAND Appropriateness' method: first, individual members of an internal multidisciplinary panel filled out the questionnaire and then the results were discussed collectively in each hospital during a 'round table' meeting. The feasibility of the process was assessed by direct observation of the round tables and with semi-structured phone interviews.ResultsThe V-HLO-fr tool was fully applied in the three targeted hospitals and the process seems to be acceptable, practicable and integrable. Strengths (e.g. the facilitation of patient navigation to the hospital) and weaknesses (e.g. the provision of easy to read, understand and act on health information materials) in terms of health literacy responsiveness have been highlighted.ConclusionV-HLO-fr can be a suitable tool for a needs assessment that allows hospitals to create awareness and formulate targeted actions to further strengthen their health literacy responsiveness. Its mode of application, formalised by taking inspiration from the RAND method, could be further improved by paying more attention to recruiting and supporting participants. The V-HLO-fr and its added value in real-world projects should now be further tested in a larger number of hospitals

    The Vienna self-assessment questionnaire: a usable tool towards more health-literate hospitals? Explorative case studies in three hospitals in Belgium

    No full text
    Background: Strengthening the capacity of hospitals to take into account the level of health literacy of their public is a necessity to improve the quality of care. One way to develop adequate health literacy responsive policy and strategies in hospitals is the use of self-assessment tools to raise awareness, help prioritise action and mobilise stakeholders. The Vienna Health Literate Organisation (V-HLO) questionnaire, recently translated and adapted into French, is designed to meet this objective. In this study we have piloted the French version of the V-HLO (V-HLO-fr) tool in the main hospitals of Liège (Belgium) to explore its feasibility and gain a first insight into the strengths and weaknesses of the health literacy responsiveness of the participating hospitals. Methods: We performed explorative case studies in three hospitals. Our mode of application of the V-HLO-fr was inspired by the ‘RAND Appropriateness’ method: first, individual members of an internal multidisciplinary panel filled out the questionnaire and then the results were discussed collectively in each hospital during a ‘round table’ meeting. The feasibility of the process was assessed by direct observation of the round tables and with semi-structured phone interviews. Results: The V-HLO-fr tool was fully applied in the three targeted hospitals and the process seems to be acceptable, practicable and integrable. Strengths (e.g. the facilitation of patient navigation to the hospital) and weaknesses (e.g. the provision of easy to read, understand and act on health information materials) in terms of health literacy responsiveness have been highlighted. Conclusion: V-HLO-fr can be a suitable tool for a needs assessment that allows hospitals to create awareness and formulate targeted actions to further strengthen their health literacy responsiveness. Its mode of application, formalised by taking inspiration from the RAND method, could be further improved by paying more attention to recruiting and supporting participants. The V-HLO-fr and its added value in real-world projects should now be further tested in a larger number of hospitals

    Comparative Sem and Tem Examination of the Ultrastructure of the Resin-dentin Interdiffusion Zone

    No full text
    The resin-dentin interdiffusion zone produced by a dentin-adhesive system that removes the smear layer and concurrently decalcifies superficial dentin was morphologically examined by both scanning and transmission electron microscopy. Cross-sectioned resin-bonded dentin discs were etched with an argon-ion beam to make the resin-dentin interface observable by SEM. For the TEM examination, the sections were partly decalcified by an aqueous EDTA solution to facilitate ultramicrotomy and to disclose the ultrastructure of the interdiffusion zone. Both SEM and TEM confirmed the presence of the resin-dentin interdiffusion zone as the junction between the deep unaltered dentin structure and the restorative resin. Within the interdiffusion zone, three sublayers with characteristic ultrastructure and staining were identified by TEM. An upper diffuse black layer contained few structural features. Underneath, partially-altered collagen fibrils were closely packed, mostly running parallel with the interface and perpendicular to the dentinal tubules. Their outline was electron-dense, forming tunnel-like structures. At the base of the upper layer, several stained projections were found to bulge out into the underlying collagen network and appeared to be confined by obstructive, parallel-running collagen fibrils. Finally, the third dense layer, containing hydroxyapatite crystals, demarcated the superficially demineralized dentin layer from the deeper unaltered dentin. Resin diffusion into the decalcified dentin surface layer was evident, but diminished with depth, presumably reducing deeper resin impregnation into the interfibrillar spaces. The citric acid dentin-pretreatment probably caused denaturation of the superficial collagen fibrils. Its decalcifying effect gradually weakened with depth, leaving behind hydroxyapatite crystals at the base of the interdiffusion zone. These crystals appeared to have been resistant to the EDTA TEM-sample decalcification procedure, which suggests that they were protected by resin encapsulation

    The interaction of adhesive systems with human dentin

    No full text
    Purpose: To investigate the interaction of six experimental and commercial bonding systems with dentin in vivo. Materials and Methods: One-Step, Clearfil Liner Bond 2, OptiBond, Permagen with 10% phosphoric acid, Permagen with 35% phosphoric acid, and Prime & Bond were applied in standard Class I occlusal cavities in premolars scheduled for extraction for orthodontic reasons, combined either with a self-cured or with a light-cured resin composite. The teeth were carefully extracted 5 minutes after resin polymerization and fixed in 2.5% glutaraldehyde. After fixation, the specimens were dehydrated, sectioned, and processed for field-emission SEM. Results: Although some systems produced gap-free intact interfaces in specific specimens, all of them showed detachment at the transition between the resin-dentin interdiffusion zone and the fluid resin placed over it. It was apparent that the presence of air-bubbles and/or thick layers of polymerized-filled fluid resin resulted in less frequent separation areas at the resin-dentin interface, providing support for the concept of the elastic cavity wall. It was also confirmed that some dentin adhesive systems do not form a thick layer over the dentin, otherwise the resin composite would not have penetrated the dentin tubules
    corecore