353 research outputs found

    Cancellation of light-shifts in an N-resonance clock

    Full text link
    We demonstrate that first-order light-shifts can be cancelled for an all-optical, three-photon-absorption resonance ("N-resonance") on the D1 transition of Rb87. This light-shift cancellation enables improved frequency stability for an N-resonance clock. For example, using a table-top apparatus designed for N-resonance spectroscopy, we measured a short-term fractional frequency stability (Allan deviation) 1.5e-11 tau^(-1/2) for observation times 1s< tau < 50s. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated N-resonance clock.Comment: 4 pages, 4 figure

    A novel absorption resonance for all-optical atomic clocks

    Full text link
    We report an experimental study of an all-optical three-photon-absorption resonance (known as a "N-resonance") and discuss its potential application as an alternative to atomic clocks based on coherent population trapping (CPT). We present measurements of the N-resonance contrast, width and light-shift for the D1 line of 87Rb with varying buffer gases, and find good agreement with an analytical model of this novel resonance. The results suggest that N-resonances are promising for atomic clock applications.Comment: 4 pages, 6 figure

    Alpine Space Prospective Study. Sustainable territorial development in the Alpine Space: Towards long term transnational cooperation

    Get PDF
    This "Prospective Study" argues that a long term transnational cooperation will be able to pursue the sustainable territorial development in the Alpine Space only at the condition of a substantial improvement of the current experience. This regards an increased awareness of the complexity of issues and challenges currently at stake in the Alpine area but especially, in this light, the capacity of involving all relevant institutional and socioeconomic stakeholders in the building of shared transnational strategie

    Investigation of microwave transitions and nonlinear magneto-optical rotation in anti-relaxation-coated cells

    Full text link
    Using laser optical pumping, widths and frequency shifts are determined for microwave transitions between ground-state hyperfine components of 85^{85}Rb and 87^{87}Rb atoms contained in vapor cells with alkane anti-relaxation coatings. The results are compared with data on Zeeman relaxation obtained in nonlinear magneto-optical rotation (NMOR) experiments, a comparison important for quantitative understanding of spin-relaxation mechanisms in coated cells. By comparing cells manufactured over a forty-year period we demonstrate the long-term stability of coated cells, an important property for atomic clocks and magnetometers

    Alpine Space Prospective Study. Sustainable territorial development in the Alpine Space: Towards long term transnational cooperation

    Get PDF
    This "Prospective Study" argues that a long term transnational cooperation will be able to pursue the sustainable territorial development in the Alpine Space only at the condition of a substantial improvement of the current experience. This regards an increased awareness of the complexity of issues and challenges currently at stake in the Alpine area but especially, in this light, the capacity of involving all relevant institutional and socioeconomic stakeholders in the building of shared transnational strategies

    Comparison of 87Rb N-resonances for D1 and D2 transitions

    Full text link
    We report an experimental comparison of three-photon-absorption resonances (known as "N-resonances") for the D_1 and D_2 optical transitions of thermal 87Rb vapor. We find that the D_2 N-resonance has better contrast, a broader linewidth, and a more symmetric lineshape than the D_1 N-resonance. Taken together, these factors imply superior performance for frequency standards operating on alkali D_2 N-resonances, in contrast to coherent population trapping (CPT) resonances for which the D_2 transition provides poorer frequency standard performance than the D_1 transition.Comment: 3 pages, 4 figure

    Establishing the precise evolutionary history of a gene improves prediction of disease-causing missense mutations

    Get PDF
    PURPOSE: Predicting the phenotypic effects of mutations has become an important application in clinical genetic diagnostics. Computational tools evaluate the behavior of the variant over evolutionary time and assume that variations seen during the course of evolution are probably benign in humans. However, current tools do not take into account orthologous/paralogous relationships. Paralogs have dramatically different roles in Mendelian diseases. For example, whereas inactivating mutations in the NPC1 gene cause the neurodegenerative disorder Niemann-Pick C, inactivating mutations in its paralog NPC1L1 are not disease-causing and, moreover, are implicated in protection from coronary heart disease. METHODS: We identified major events in NPC1 evolution and revealed and compared orthologs and paralogs of the human NPC1 gene through phylogenetic and protein sequence analyses. We predicted whether an amino acid substitution affects protein function by reducing the organism’s fitness. RESULTS: Removing the paralogs and distant homologs improved the overall performance of categorizing disease-causing and benign amino acid substitutions. CONCLUSION: The results show that a thorough evolutionary analysis followed by identification of orthologs improves the accuracy in predicting disease-causing missense mutations. We anticipate that this approach will be used as a reference in the interpretation of variants in other genetic diseases as well. Genet Med 18 10, 1029–1036

    Treacher Collins syndrome with choanal atresia: a case report and review of disease features

    Get PDF
    SummaryTreacher Collins Syndrome - or mandibulofacial dysostosis – is a rare condition that presents several craniofacial deformities of different levels. This is a congenital malformation involving the first and second branchial arches. Incidence is estimated to range between 1-40,000 to 1-70,000 of live births. The disorder is characterized by abnormalities of the auricular pinna, hypoplasia of facial bones, antimongoloid slanting palpebral fissures with coloboma of the lower eyelids and cleft palate. Treacher Collins Syndrome is rarely associated with choanal atresia. A multidisciplinary team, including craniofacial surgeon, ophthalmologist, speech therapist, dental surgeon and otorhinolaryngologist, is the most appropriate setting to manage these patients. This study reports a rare case of Treacher Collins Syndrome with choanal atresia, presenting literature review and multidisciplinary intervention

    Theoretical study of dark resonances in micro-metric thin cells

    Full text link
    We investigate theoretically dark resonance spectroscopy for a dilute atomic vapor confined in a thin (micro-metric) cell. We identify the physical parameters characterizing the spectra and study their influence. We focus on a Hanle-type situation, with an optical irradiation under normal incidence and resonant with the atomic transition. The dark resonance spectrum is predicted to combine broad wings with a sharp maximum at line-center, that can be singled out when detecting a derivative of the dark resonance spectrum. This narrow signal derivative, shown to broaden only sub-linearly with the cell length, is a signature of the contribution of atoms slow enough to fly between the cell windows in a time as long as the characteristic ground state optical pumping time. We suggest that this dark resonance spectroscopy in micro-metric thin cells could be a suitable tool for probing the effective velocity distribution in the thin cell arising from the atomic desorption processes, and notably to identify the limiting factors affecting desorption under a grazing incidence.Comment: 12 pages, 11 figures theoretical articl

    Metrological characterization of the pulsed Rb clock with optical detection

    Full text link
    We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in detail in the paper. The prototype is designed and optimized to detect the clock transition in the optical domain. Specifically, the reference atomic transition, excited with a Ramsey scheme, is detected by observing the interference pattern on a laser absorption signal. \ The metrological analysis includes the observation and characterization of the clock signal and the measurement of frequency stability and drift. In terms of Allan deviation, the measured frequency stability results as low as 1.7×1013 τ1/21.7\times 10^{-13} \ \tau^{-1/2}, τ\tau being the averaging time, and reaches the value of few units of 101510^{-15} for τ=104\tau=10^{4} s, an unprecedent achievement for a vapor cell clock. We discuss in the paper the physical effects leading to this result with particular care to laser and microwave noises transferred to the clock signal. The frequency drift, probably related to the temperature, stays below 101410^{-14} per day, and no evidence of flicker floor is observed. \ We also mention some possible improvements that in principle would lead to a clock stability below the 101310^{-13} level at 1 s and to a drift of few units of 101510^{-15} per day
    corecore