    Om de diverse landschappen van Renesse optimaal te beleven stippen wij vier routes aan: • De Wijnas • De Renesseboulevard • De Beekzoom • De Strandroute. Door op deze routes te focussen, waar de meeste mensen zich over bewegen, wordt het eenvoudiger om de landschappen zelf aan te pakken en wordt zo de diversiteit aan landschappen toegankelijk

    Structural and non-structural carbohydrates in concentrate supplements of silage based dairy cow rations.

    Get PDF
    Resultaten van een onderzoek naar de effecten van het type koolhydraat (zetmeel en celwandbestanddelen) in krachtvoermengsels en verschillen in afbraaksnelheid op de opname en melkprodukti

    Do Media Players Cause Interference with Pacemakers?

    Full text link
    Background Electrical devices generate electromagnetic fields that may interfere with pacemakers. Media players cause telemetry interference with pacemakers, but it is not known whether they cause direct interference with pacemakers. The purpose of this study was to examine the interaction between pacemakers and 3 different media players. Methods In this prospective, randomized study, 54 patients with dual chamber pacemakers who were in sinus rhythm underwent baseline observation, followed by observation under telemetry communication. These patients were then randomly evaluated with 3 media players (iPod 3G, iPod Photo, and iPod Touch Apple, Cupertino, CA) with and without telemetry communication for 1 minute each. Patients were monitored for pacemaker malfunction using a single-channel ECG during exposure to media players. The pacemaker was interrogated after each exposure and an interrogation report was printed for evaluation. Pacemaker interference was categorized as type I, II, or III. Types I and II interference described telemetry interference and type III interference was defined as any direct interference with pacemaker function or programmed parameters. Results A total of 54 patients (29 men and 25 women; mean age 77.2 ± 9.3 y) were evaluated. In total, of the 162 tests (for telemetry interference) 36.4% were positive (Type I and II). Type III interference was also evaluated in 162 tests and none showed any evidence of direct interference. Conclusion Media players cause telemetry interference with pacemakers, but they do not directly interfere with pacemaker function. Copyright © 2009 Wiley Periodicals, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/64532/1/20625_ftp.pd

    Ruminal behaviour of structural carbohydrates, non-structural carbohydrates and crude protein from concentrate ingredients in dairy cows.

    Get PDF
    Resultaten van een onderzoek naar afbraakeigenschappen van Neutral Detergent Fibre (NDF), zetmeel en ruw eiwit in krachtvoeringrediente

    Hypothesis: inflammatory acid-base disruption underpins Long Covid

    Get PDF
    The mechanism of Long Covid (Post-Acute Sequelae of COVID-19; PASC) is currently unknown, with no validated diagnostics or therapeutics. SARS-CoV-2 can cause disseminated infections that result in multi-system tissue damage, dysregulated inflammation, and cellular metabolic disruptions. The tissue damage and inflammation has been shown to impair microvascular circulation, resulting in hypoxia, which coupled with virally-induced metabolic reprogramming, increases cellular anaerobic respiration. Both acute and PASC patients show systemic dysregulation of multiple markers of the acid-base balance. Based on these data, we hypothesize that the shift to anaerobic respiration causes an acid-base disruption that can affect every organ system and underpins the symptoms of PASC. This hypothesis can be tested by longitudinally evaluating acid-base markers in PASC patients and controls over the course of a month. If our hypothesis is correct, this could have significant implications for our understanding of PASC and our ability to develop effective diagnostic and therapeutic approaches

    Characteristics of Telemetry Interference with Pacemakers Caused by Digital Media Players

    Full text link
    Background: Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. Methods & Results: We studied the characteristics of interference with uplink (real time intracardiac electrograms, marker channel, and stored histograms) and downlink (attempt to program a change in the lower rate limit, the pacing mode, and the ventricular lead configuration) data transmission between the wand and the pacemaker caused by digital media players (iPods—Photo and 3G) in 50 patients. We also measured and characterized worst-case magnetic field emissions (MFE) from the wand (≤0.4 μT), pacemaker (≤0.004 μT), and iPod (≤0.05 μT) during telemetry to understand the modulation techniques and safety protocols employed during data transmission. Telemetry interference (TI) manifested as high-frequency spikes (24.4%), blanking (17.7%) and interruption (22.2%), or delay (17.6%) in transmission with warning on programmer's screen. TI occurred in 25.6% of patients when the iPod was “on” and in 13% even with the iPod turned “off.” There were no inaccuracies in downlinked data when the downlink communication was successful. Wanded telemetry utilizes low-frequency (30–300 kHz) radiowaves and simple digital modulation techniques at relatively slow rates for “sequential” data transmission protected by a continuous “handshake.” Emissions from iPods in that range interrupt the telemetry link but are too weak to cause pacemaker malfunction through corruption of vital data. Conclusion: Low-power MFE from iPods can produce interference with establishment and maintenance of a telemetry link and can cause TI with transmission of real time data, but because of continuous check protocols, do not corrupt the stored and vital downlink data. (PACE 2010; 33:712–720)Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/78697/1/j.1540-8159.2009.02672.x.pd
    • …