143 research outputs found

    Applying V2V for operational safety within cooperative adaptive cruise control

    Get PDF
    Cooperative Adaptive Cruise Control aims to automate a truck longitudinally for following its predecessor at reduced following distances in order to minimize fuel consumption. Short inter vehicle distances can be realised by the use of Vehicle-To-Vehicle communication (V2V). This application should be operational safe, which means to prevent harm to personnel in hazardous situations in case the system is fully operational: the system should avoid collisions with other road participants and with the leading truck. This paper proposes to use V2V communication in a platoon to share information on surrounding traffic participants in order to predict possible hazardous traffic situations continuously, which could be used to ensure functional safety in case of V2V failure. In case these situations can be predicted in time, actions could be taken to avoid collisions. <br/

    Evaluation of bifurcation stenting techniques at Catharina Hospital, Eindhoven in 2013

    Get PDF
    AimsPercutaneous coronary intervention (PCI) of bifurcation lesions can be performed using various techniques. The aim of this study was to analyse the outcome of various techniques of bifurcation stenting in all patients undergoing bifurcation stenting at one large intervention centre in 2013, taking into account that more complex lesions might more often warrant a two-stent technique.Methods and resultsThis retrospective study included 260 consecutive patients who underwent non-primary PCI of a bifurcation lesion at the Catharina Hospital, Eindhoven, in 2013. Patients were classified into two groups: one-stent technique (provisional stenting), and two-stent techniques (culotte, crush and T‑stenting). The primary endpoint was the rate of restenosis at 1 year. The secondary endpoints were procedural complications (side branch occlusion, periprocedural infarction, and death) and major adverse cardiac events (MACE) at 1 year. Periprocedural complications occurred in 15 patients (5.8 %) with no difference between the groups (p = 0.27). After 1 year, restenosis occurred in 3.2 % of the patients in the one-stent technique group and 7.3 % in the two-stent technique group (p = 0.20). MACE at 1 year did not differ between the groups at 11.9 % and 12.2 % respectively (p = 1.00).ConclusionsThis study shows that there is no significant difference between restenosis rate, or any other outcome parameter, with the different techniques of bifurcation stenting. Since provisional stenting is the simplest, most straightforward and cheapest approach, if technically feasible this technique has our preference as the initial approach, and an upgrade can be considered if the result is insufficient.KeywordsPercutaneous coronary interventionBifurcationStentingCulotteCrushProvisional stentingT-stentin

    Temporal resolution deficits in the visual fields of MS patients

    Get PDF
    AbstractWe assessed the relationship between temporal resolution and MS-induced neuropathy. A diagnostic strategy comprising assessments of temporal resolution at 16 points in the extra-foveal visual field up to 12° from the fovea was first compared with foveal temporal resolution and with a standard VEP procedure in the same MS patients. At the group level, foveal temporal resolution was less sensitive to demyelination than the 16-point diagnostic strategy, the detection rate of which was comparable to that of the VEP procedure. Cross-sensitivity of the VEP and the 16-point diagnostic procedure was low. Subsequently, the average severity of MS-induced temporal resolution deficits was studied at three retinal loci of the same size but different eccentricities. Foveal deficits were not significantly greater than more peripheral deficits within the central 12°

    Robustness of intra urban land-use regression models for ultrafine particles and black carbon based on mobile monitoring.

    Get PDF
    Land-use regression (LUR) models for ultrafine particles (UFP) and Black Carbon (BC) in urban areas have been developed using short-term stationary monitoring or mobile platforms in order to capture the high variability of these pollutants. However, little is known about the comparability of predictions of mobile and short-term stationary models and especially the validity of these models for assessing residential exposures and the robustness of model predictions developed in different campaigns. We used an electric car to collect mobile measurements (n = 5236 unique road segments) and short-term stationary measurements (3 × 30min, n = 240) of UFP and BC in three Dutch cities (Amsterdam, Utrecht, Maastricht) in 2014-2015. Predictions of LUR models based on mobile measurements were compared to (i) measured concentrations at the short-term stationary sites, (ii) LUR model predictions based on short-term stationary measurements at 1500 random addresses in the three cities, (iii) externally obtained home outdoor measurements (3 × 24h samples; n = 42) and (iv) predictions of a LUR model developed based upon a 2013 mobile campaign in two cities (Amsterdam, Rotterdam). Despite the poor model R(2) of 15%, the ability of mobile UFP models to predict measurements with longer averaging time increased substantially from 36% for short-term stationary measurements to 57% for home outdoor measurements. In contrast, the mobile BC model only predicted 14% of the variation in the short-term stationary sites and also 14% of the home outdoor sites. Models based upon mobile and short-term stationary monitoring provided fairly high correlated predictions of UFP concentrations at 1500 randomly selected addresses in the three Dutch cities (R(2) = 0.64). We found higher UFP predictions (of about 30%) based on mobile models opposed to short-term model predictions and home outdoor measurements with no clear geospatial patterns. The mobile model for UFP was stable over different settings as the model predicted concentration levels highly correlated to predictions made by a previously developed LUR model with another spatial extent and in a different year at the 1500 random addresses (R(2) = 0.80). In conclusion, mobile monitoring provided robust LUR models for UFP, valid to use in epidemiological studies

    Transplacentally Acquired Maternal Antibody against Hepatitis B Surface Antigen in Infants and its Influence on the Response to Hepatitis B Vaccine

    Get PDF
    BACKGROUND: Passively acquired maternal antibodies in infants may inhibit active immune responses to vaccines. Whether maternal antibody against hepatitis B surface antigen (anti-HBs) in infants may influence the long-term immunogenicity of hepatitis B vaccine remains unknown. METHODOLOGY/PRINCIPAL FINDINGS: Totally 338 pairs of mothers and children were enrolled. All infants were routinely vaccinated against hepatitis B based on 0-, 1- and 6-month schedule. We characterized the transplacental transfer of maternal anti-HBs, and compared anti-HBs response in children of mothers with or without anti-HBs. In a prospective observation, all 63 anti-HBs positive mothers transferred anti-HBs to their infants; 84.1% of the infants had higher anti-HBs concentrations than their mothers. One and half years after vaccination with three doses of hepatitis B vaccine, the positive rate and geometric mean concentration (GMC) of anti-HBs in 32 infants with maternal anti-HBs were comparable with those in 32 infants without maternal antibody (90.6% vs 87.5%, P = 0.688, and 74.5 vs 73.5 mIU/ml, P = 0.742, respectively). In a retrospective analysis, five and half years after vaccination with three doses vaccine, the positive rates of anti-HBs in 88 children of mothers with anti-HBs ≥1000 mIU/ml, 94 children of mothers with anti-HBs 10-999 mIU/ml, and 61 children of mothers with anti-HBs <10 mIU/ml were 72.7%, 69.2%, and 63.9% (P = 0.521), respectively; anti-HBs GMC in these three groups were 38.9, 43.9, and 31.7 mIU/ml (P = 0.726), respectively. CONCLUSIONS/SIGNIFICANCE: The data demonstrate that maternal anti-HBs in infants, even at high concentrations, does not inhibit the long-term immunogenicity of hepatitis B vaccine. Thus, current hepatitis B vaccination schedule for infants will be still effective in the future when most infants are positive for maternal anti-HBs due to the massive vaccination against hepatitis B

    Intervju: akademik Jakša Barbić

    Get PDF
    Over the past 20 years evidence has accumulated confirming the immunomodulatory role of the appendix in ulcerative colitis (UC). This led to the idea that appendectomy might alter the clinical course of established UC. The objective of this body of research is to evaluate the short-term and medium-term efficacy of appendectomy to maintain remission in patients with UC, and to establish the acceptability and cost-effectiveness of the intervention compared to standard treatment. These paired phase III multicenter prospective randomised studies will include patients over 18 years of age with an established diagnosis of ulcerative colitis and a disease relapse within 12 months prior to randomisation. Patients need to have been medically treated until complete clinical (Mayo score <3) and endoscopic (Mayo score 0 or 1) remission. Patients will then be randomised 1:1 to a control group (maintenance 5-ASA treatment, no appendectomy) or elective laparoscopic appendectomy plus maintenance treatment. The primary outcome measure is the one year cumulative UC relapse rate - defined both clinically and endoscopically as a total Mayo-score ≥5 with endoscopic subscore of 2 or 3. Secondary outcomes that will be assessed include the number of relapses per patient at 12 months, the time to first relapse, health related quality of life and treatment costs, and number of colectomies in each arm. The ACCURE and ACCURE-UK trials will provide evidence on the role and acceptability of appendectomy in the treatment of ulcerative colitis and the effects of appendectomy on the disease course. NTR2883 ; ISRCTN5652301
    corecore