20 research outputs found

    A Multicenter, Prospective, Randomized, Contralateral Study of Tissue Liquefaction Liposuction vs Suction-Assisted Liposuction

    Get PDF
    Tissue liquefaction liposuction (TLL) deploys a novel energy source utilizing a stream of warmed, low-pressurized, and pulsed saline to extract fat tissue. Objectives: Compare TLL to suction-assisted liposuction (SAL) to determine which device is more efficient for surgeons and provides better recovery for patients. Methods: Thirty-one adult female patients were followed prospectively in a contralateral study design comparing differences in bruising, swelling, tenderness, and incision appearance ratings between TLL and SAL procedures. Surgical efficiency and appearance of the lipoaspirate were also compared. Results: All 31 patients successfully completed the study. For TLL and SAL procedures, the average volumes of infusion (1.242 vs 1.276 L) and aspirated supernatant fat (704 vs 649 mL) were statistically similar. TLL median fat extraction rate was faster than SAL (35.6 vs 25 mL/min; P < 0.0001), and stroke rate was reduced in TLL vs SAL procedures (48 vs 120 strokes/min; P < 0.0001), and both were statistically significant. The mean total scores for bruising, swelling, treatment site tenderness, and incision appearance were lower, indicating improved patient recovery on the TLL side. Conclusions: TLL and SAL techniques produced comparable volume of fat aspirate. TLL demonstrated a 42% faster fat extraction rate and a 68% reduction in arm movements needed to complete the procedure compared to SAL, both of these differences are statistically significant. The TLL side was noted to have reduced bruising and swelling and improved incision site appearance with less tenderness compared to the SAL side

    Biofilm Derived Oxylipin Mediated Autoimmune Response in Breast Implant Subjects

    Get PDF
    Over 10 million women worldwide have breast implants for breast cancer/prophylactic reconstruction or cosmetic augmentation. In recent years, a number of patients have described a constellation of symptoms that are believed to be related to their breast implants. This constellation of symptoms has been named Breast Implant Illness (BII). The symptoms described include chronic fatigue, joint pain, muscle pain and a host of other manifestations often associated with autoimmune illnesses. In this work, we report that bacterial biofilm is associated with BII. We postulate that the pathogenesis of BII is mediated via a host-pathogen interaction whereby the biofilm bacteria Staphylococcus epidermidis interacts with breast lipids to form the oxylipin 10-HOME. The oxylipin 10-HOME was found to activate CD4+ T cells to Th1 subtype. An increased abundance of CD4+Th1 was observed in the breast tissue of BII subjects. The identification of a mechanism of immune activation associated with BII via a biofilm enabled pathway provides insight into the pathogenesis for implant-associated autoimmune symptoms

    Ten-Year Results From the Natrelle 410 Anatomical Form-Stable Silicone Breast Implant Core Study

    Get PDF
    Background: Silicone breast implants have long been used for breast augmentation and reconstruction. During this time, these medical devices have gone through a number of modifications to improve their safety, quality, and clinical outcome performance. Objectives: The authors conducted a 10-year study to determine the safety and effectiveness of Natrelle 410 silicone breast implants. Methods: This prospective, multicenter study enrolled 941 subjects who were undergoing either augmentation, augmentation revision, reconstruction, or reconstruction revision. Data on complications, reoperations, explantations, and subject satisfaction were collected at annual clinic visits, and one-third of subjects underwent biennial magnetic resonance imaging (MRI) to screen for implant rupture. The authors used the Kaplan-Meier estimator to calculate risk rates for local complications, reoperations, and explantations. Results: Capsular contracture rates increased approximately 1% per year from the previously reported 6-year rates. The rates were significantly lower than those from the Natrelle round gel core study. The overall rate of confirmed ruptured implants in subjects who underwent MRI was 5.7%. Eleven late seromas were reported. The most common reason for explantation was a subject requesting a size or style change. Satisfaction rates remained high through 10 years, with most subjects saying they were somewhat or definitely satisfied with their implants. Conclusions: This 10-year prospective trial demonstrated the long-term safety and effectiveness of Natrelle 410 anatomical form-stable implants. The complication rates were low and the satisfaction rates were high

    Biomarkers provide clues to early events in the pathogenesis of breast implant-associated anaplastic large cell lymphoma

    No full text
    Almost 200 women worldwide have been diagnosed with breast implant-associated anaplastic large cell lymphoma (BIA-ALCL). The unique location and specific lymphoma type strongly suggest an etio-pathologic link between breast implants and BIA-ALCL. It is postulated that chronic inflammation via bacterial infection may be an etiological factor. BIA-ALCL resembles primary cutaneous ALCL (pcALCL) in morphology, activated T-cell phenotype, and indolent clinical course. Gene expression array analysis, flow cytometry, and immunohistochemistry were used to study pcALCL and BIA-ALCL cell lines. Clinical samples were also studied to characterize transcription factor and cytokine profiles of tumor cells and surrounding lymphocytes. BIA-ALCL and pcALCL were found to have common expression of transcription factors SOCS3, JunB, SATB1, and a cytokine profile suggestive of a Th1 phenotype. Similar patterns were observed in a CD30+ cutaneous lymphoproliferative disorder (LPD). The patterns of cytokine and transcription factor expression suggest that BIA-ALCL is likely to arise from chronic bacterial antigen stimulation of T-cells. Further analysis of cytokine and transcription factor profiles may allow early detection and treatment of BIA-ALCL leading to better prognosis and survival.9 page(s

    Die Gewinnung von einheitlichen und regelmäßigen Polymeren

    No full text

    Glucose sensor-augmented continuous subcutaneous insulin infusion in patients with diabetic gastroparesis: An open-label pilot prospective study

    No full text
    <div><p>Erratic blood glucose levels can be a cause and consequence of delayed gastric emptying in patients with diabetes. It is unknown if better glycemic control increases risks of hypoglycemia or improves hemoglobin A1c levels and gastrointestinal symptoms in diabetic gastroparesis. This study investigated the safety and potential efficacy of continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) in poorly controlled diabetes with gastroparesis. Forty-five type 1 or 2 patients with diabetes and gastroparesis and hemoglobin A1c >8% from the NIDDK Gastroparesis Consortium enrolled in a 24 week open-label pilot prospective study of CSII plus CGM. The primary safety outcome was combined numbers of mild, moderate, and severe hypoglycemic events at screening and 24 weeks treatment. Secondary outcomes included glycemic excursions on CGM, hemoglobin A1c, gastroparesis symptoms, quality-of-life, and liquid meal tolerance. Combined mild, moderate, and severe hypoglycemic events occurred similarly during the screening/run-in (1.9/week) versus treatment (2.2/week) phases with a relative risk of 1.18 (95% CI 0.85–1.64, P = 0.33). CGM time in hypoglycemia (<70 mg/dL) decreased from 3.9% to 1.8% (P<0.0001), time in euglycemia (70–180 mg/dL) increased from 44.0% to 52.0% (P = 0.02), time in severe hyperglycemia (>300 mg/dL) decreased from 14.2% to 7.0% (P = 0.005), and hemoglobin A1c decreased from 9.4±1.4% to 8.3±1.3% (P = 0.001) on CSII plus CGM. Symptom scores decreased from 29.3±7.1 to 21.9±10.2 with lower nausea/vomiting, fullness/early satiety, and bloating/distention scores (P≤0.001). Quality-of-life scores improved from 2.4±1.1 to 3.1±1.1 (P<0.0001) and volumes of liquid nutrient meals tolerated increased from 420±258 to 487±312 mL (P = 0.05) at 24 weeks. In conclusion, CSII plus CGM appeared to be safe with minimal risks of hypoglycemic events and associated improvements in glycemic control, gastroparesis symptoms, quality-of-life, and meal tolerance in patients with poorly controlled diabetes and gastroparesis. This study supports the safety, feasibility, and potential benefits of improving glycemic control in diabetic gastroparesis.</p></div
    corecore