19 research outputs found

    Influence of remaining coronal thickness and height on biomechanical behavior of endodontically treated teeth: survival rates, load to fracture and finite element analysis

    Get PDF
    Objective: To evaluate the effect of restorative strategy (fiber post vs cast post and core), coronal height (0 mm vs 2 mm) and thickness (higher than 1 mm vs lower than 1 mm) on survival rate, fracture resistance and stress distribution. Material and Methods: Seventy-two bovine teeth were cleaned and allocated in six groups (n = 12). Twenty-four teeth were sectioned at 13 mm length (no remaining coronal structure) and forty-eight were sectioned at 15 mm (2 mm remaining coronal structure). Half of the forty-eight had remaining coronal thickness lower than 1 mm and the other half had thickness higher than 1 mm. All root canals were prepared at 10 mm (luting length), fiber posts were cemented in thirty-six specimens and cast post and core in other thirty-six. All teeth were restored with metallic crowns. Specimens were submitted to 1.5 million cycles (100 N, 45°, 10 Hz at 2 mm below incisal edge) and evaluated at each 500,000 cycles to detect failures. Specimens that survived were submitted to load to fracture test. Bidimensional (Rhinoceros® 4.0) models were obteined survival data submitted to Kaplan-Meier (α=0.05) analysis and load to fracture values submitted to ANOVA and Tukey tests (α=0.05). Results: Groups without remaining coronal structure showed survival rates lower than other groups (p=0.001). ANOVA showed higher values of load to fracture for groups with coronal thickness higher than 1 mm (p=0.0043). Finite element analysis showed better stress distribution in groups with remaining coronal structure and restored with fiber post. Conclusion: Specimens without remaining coronal structure have lower survival rates. Specimens with remaining structure lower than 1 mm and without coronal structure support the same load to fracture value independently of the restorative strategy

    Clinical outcomes and success rates of quartz fiber post restorations: A retrospective study

    No full text
    Statement of problem Cast metal posts and dowels are inherently dark and, when metal-free restorations are used, could impair the definitive esthetic appearance. Quartz fiber posts could represent a reliable choice for restoring abutment teeth. Purpose The purpose of this study was to evaluate the long-term success rate of teeth restored with quartz fiber posts and fixed dental prostheses (FDPs). Material and methods Ninety-nine teeth restored with 114 quartz fiber posts and FDPs were evaluated. The evaluation time ranged from 7 months to 9.25 years. The Kaplan-Meier method was used to obtain success curves. The influence of the tooth location, definitive restoration, and failure pattern upon the success function was analyzed with the log-rank test. The Cox regression test was used to evaluate possible predictors among the interactions of the observed parameters. Results The success rate of the restorations was 85.86% in a mean period of 5.88 \ub11.37 years, with an estimated success probability of 85% at 6.17 years. The statistical analysis identified the factors related to the arch (P=.045) and type of definitive restoration (P=.021) as significantly associated with success. Post debonding was the most frequent failure mode, followed by endodontic failure, with the latter not necessarily being related to the post itself. No root fractures were recorded. Twelve teeth out of the 14 that failed were restored again, bringing the overall survival rate of the teeth to 98%. Conclusions The rehabilitation of abutment teeth with quartz fiber posts can be considered a reliable procedure; however, adhesive techniques and luting materials require improvement.Statement of problem Cast metal posts and dowels are inherently dark and, when metal-free restorations are used, could impair the definitive esthetic appearance. Quartz fiber posts could represent a reliable choice for restoring abutment teeth. Purpose The purpose of this study was to evaluate the long-term success rate of teeth restored with quartz fiber posts and fixed dental prostheses (FDPs). Material and methods Ninety-nine teeth restored with 114 quartz fiber posts and FDPs were evaluated. The evaluation time ranged from 7 months to 9.25 years. The Kaplan-Meier method was used to obtain success curves. The influence of the tooth location, definitive restoration, and failure pattern upon the success function was analyzed with the log-rank test. The Cox regression test was used to evaluate possible predictors among the interactions of the observed parameters. Results The success rate of the restorations was 85.86% in a mean period of 5.88 \ub11.37 years, with an estimated success probability of 85% at 6.17 years. The statistical analysis identified the factors related to the arch (P=.045) and type of definitive restoration (P=.021) as significantly associated with success. Post debonding was the most frequent failure mode, followed by endodontic failure, with the latter not necessarily being related to the post itself. No root fractures were recorded. Twelve teeth out of the 14 that failed were restored again, bringing the overall survival rate of the teeth to 98%. Conclusions The rehabilitation of abutment teeth with quartz fiber posts can be considered a reliable procedure; however, adhesive techniques and luting materials require improvement

    Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic: microtensile versus shear test

    No full text
    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC) methods were evaluated: (1) 110-mu m Al(2)O(3)+Silanization; (2) Chairside silica coating+silanization: (3) Laboratory silica coating+silanization. Following surface conditioning, the resin cement (Panavia F) was bonded to the conditioned ceramics. Although no statistically significant differences (p=0.1076) were seen between the test methods, results yielded with the different surface conditioning methods showed statistically significant differences (pSC1.). As for the interaction between the factors, two-way ANOVA showed that it was not statistically significant (p=0.1443). MTBS test resulted in predominantly mixed failure (85%), but SBS test resulted in exclusively adhesive failure. On the effects of different surface conditioning methods, chairside and laboratory tribochemical silica coating followed by silanization showed higher bond strength results compared to those of aluminum oxide abrasion and silanization, independent of the test method employed

    Hard machining, glaze firing and hydrofluoric acid etching: Do these procedures affect the flexural strength of a leucite glass-ceramic?

    No full text
    Objective. To evaluate the effects of hard machining, glaze firing and hydrofluoric acid etching on the biaxial flexural strength and roughness of a CAD/CAM leucite glass-ceramic; to investigate if ceramic post-machining surface roughness is influenced by the machining order and by the pair of burs used for it.Methods. A hundred forty four discs were machined by six nominally identical pairs of burs and divided into groups (n = 24): (1) machining-M, (2) machining and glaze firing-MG, (3) machining and hydrofluoric acid etching-MA, (4) machining, glaze firing and hydrofluoric acid etching-MGA, (5) machining followed by polishing, as a control-MP, (6) machining, polishing and hydrofluoric acid etching-MPA. The roughness after each treatment (R-a, and R-z) was measured. The discs were submitted to a piston-on-three ball flexure test (ISO 6872/2008) and strength data analyzed through Weibull statistics (95% CI).Results. M resulted in lower characteristic strength (sigma(0)) (128.2 MPa) than MP (177.2 MPa). The glaze firing reduced sigma(0) (109 MPa), without affecting roughness. Hydrofluoric acid etching increased the roughness without affecting sigma(0) Spearman's coefficient (r(s)) indicated strong and significant correlation between machining order and roughness (r(s)R(a) = -0.66; r(s)R(Z), = -0.73). The ceramic post-machining surface roughness differed significantly according to the pair of burs employed (p < 0.05).Significance. hard machining and glaze firing reduced the leucite ceramic strength, while hydrofluoric acid etching did not affect the strength. Variability in the roughness might be expected after machining, since it was influenced by the machining order and by the bur pairing. (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    A critical evaluation of bond strength tests for the assessment of bonding to Y-TZP

    No full text
    Objectives. To compare three different designs for measuring the bond strength between Y-TZP ceramic and a composite material, before and after ceramic surface treatment, evaluating the influence of the size of the adhesive interface for each design.Methods. 'Macro'tensile, microtensile, 'macro'shear, microshear, 'macro'push-out, and micropush-out tests were carried out. Two Y-TZP surface treatments were evaluated: silanization (sil) and tribochemical silica coating (30 mu m silica-modified Al2O3 particles + silanization) (TBS). Failure mode analysis of tested samples was also performed. Results. Both the surface treatment and the size of the bonded interface significantly affected the results (p = 0.00). Regardless of the type of surface treatment, the microtensile and microshear tests had higher values than their equivalent "macro" tests. However, the push-out test showed the highest values for the "macro" test. The tensile tests showed the greatest variability in results. The tribochemical silica coating method significantly increased bond strength for all tests.Significance. Different test designs can change the outcome for Y-TZP/cement interfaces, in terms of mean values and reliability (variability). The 'micro'tests expressed higher bond strengths than their equivalent 'macro'tests, with the exception of the push-out test (macro > micro). (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved

    Air-particle abrasion on zirconia ceramic using different protocols: Effects on biaxial flexural strength after cyclic loading, phase transformation and surface topography

    No full text
    This study evaluated the effect of different air-particle abrasion protocols on the biaxial flexural strength and structural stability of zirconia ceramics. Zirconia ceramic specimens (ISO 6872) (Lava, 3M ESPE) were obtained (N=336). The specimens (N=118, n=20 per group) were randomly assigned to one of the air-abrasion protocols: Gr1: Control (as-sintered); Gr2: 50 μm Al2O3 (2.5 bar); Gr3: 50 μm Al2O3 (3.5 bar); Gr4: 110 μm Al2O3(2.5 bar); Gr5: 110 μm Al2O3 (3.5 bar); Gr6: 30 μm SiO2 (2.5 bar) (CoJet); Gr7: 30 μm SiO2(3.5 bar); Gr8: 110 μm SiO2 (2.5 bar) (Rocatec Plus); and Gr9: 110 μm SiO2 (3.5 bar) (duration: 20 s, distance: 10 mm). While half of the specimens were tested immediately, the other half was subjected to cyclic loading in water (100,000 cycles; 50 N, 4 Hz, 37 °°C) prior to biaxial flexural strength test (ISO 6872). Phase transformation (t→m), relative amount of transformed monoclinic zirconia (FM), transformed zone depth (TZD) and surface roughness were measured. Particle type (p=0.2746), pressure (p=0.5084) and cyclic loading (p=0.1610) did not influence the flexural strength. Except for the air-abraded group with 110 μm Al2O3 at 3.5 bar, all air-abrasion protocols increased the biaxial flexural strength (MPa) (Controlnon-aged: 1030±153, Controlaged: 1138±138; Experimentalnon-aged: 1307±184-1554±124; Experimentalaged: 1308±118-1451±135) in both non-aged and aged conditions, respectively. Surface roughness (Ra) was the highest with 110 μm Al2O3(0.84 μm. FM values ranged from 0% to 27.21%, higher value for the Rocatec Plus (110 μm SiO2) and 110 μm Al2O3 groups at 3.5 bar pressure. TZD ranged between 0 and 1.43 μm, with the highest values for Rocatec Plus and 110 μm Al2O3 groups at 3.5 bar pressure. © 2013 Elsevier Ltd

    Fatigue Failure Load of Lithium Disilicate Restorations Cemented on a Chairside Titanium‐Base

    Full text link
    PurposeTo evaluate the fatigue failure load of distinct lithium disilicate restoration designs cemented on a chairside titanium base for maxillary anterior implant‐supported restorations.Materials and MethodsA left‐maxillary incisor restoration was virtually designed and sorted into 3 groups: (n = 10/group; CTD: lithium disilicate crowns cemented on custom‐milled titanium abutments; VMLD: monolithic full‐contour lithium disilicate crowns cemented on a chairside titanium‐base; VCLD: lithium disilicate crowns bonded to lithium disilicate customized anatomic structures and then cemented onto a chairside titanium base). The chairside titanium base was air‐abraded with aluminum oxide particles. Subsequently, the titanium base was steam‐cleaned and air‐dried. Then a thin coat of a silane agent was applied. The intaglio surface of the ceramic components was treated with 5% hydrofluoric acid (HF) etching gel, followed by silanization, and bonded with a resin cement. The specimens were fatigued at 20 Hz, starting with a 100 N load (5000× load pulses), followed by stepwise loading from 400 N up to 1400 N (200 N increments) at a maximum of 30,000 cycles each. The failure loads, number of cycles, and fracture analysis were recorded. The data were statistically analyzed using one‐way ANOVA, followed by pairwise comparisons (p < 0.05). Kaplan‐Meier survival plots and Weibull survival analyses were reported.ResultsFor catastrophic fatigue failure load and the total number of cycles for failure, VMLD (1260 N, 175,231 cycles) was significantly higher than VCLD (1080 N, 139,965 cycles) and CDT (1000 N, 133,185 cycles). VMLD had a higher Weibull modulus demonstrating greater structural reliability.ConclusionVMLD had the best fatigue failure resistance when compared with the other two groups.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/152519/1/jopr12911_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/152519/2/jopr12911.pd
    corecore