263 research outputs found

    An epistemology of noise

    Get PDF
    Malaspina’s An Epistemology of Noise is a philosophical discussion of the concept of noise, illuminating both its preconditions and its far-reaching im- plications. In a literal sense, “noise” describes possible forms of human percep- tion related to aesthetics, acoustics, and audiometry. Figuratively, noise con- notes a range of negative qualities associated with disturbance, disruption, or perturbation. After we recognize that noise, especially in its aesthetic or com- monsense usage, is defined relationally, and occupies the negative position in a dichotomy with sound, we might ask: is there anything more to know to about noise? An Epistemology of Noise proves that there is. Considering noise an epis- temological problem as Malaspina does, its structural relevance for the theory of knowledge becomes clear. Indeed, Malaspina shows that noise allows us to address the epistemological question “how does knowledge constitute itself in the face of contingency”? and its flip-side “what role does uncertainty play in the constitution of knowledge”? (39) In this respect, the potential of the notion of noise has been largely neglected and is therefore still unexplored

    Georges Canguilhem on sex determination and the normativity of life

    Get PDF
    Our goal in this paper is to reassess the relationship between norms and life by drawing on the philosophy of Georges Canguilhem, particularly some of his unpublished lectures about teratology and sexual determination. First, we discuss the difficulties Canguilhem identified in the introduction of life and sexuality as objects of philosophical reflection. Second, we reassess Canguilhem’s understanding of normativity as rooted in life and the axiological activity of the living. Third, we analyze how Canguilhem drew from past and contemporary teratology to conceive of the notions of anomaly and abnormality. Finally, we reconstruct Canguilhem’s analysis of a case of hermaphroditism, highlighting how he presented it as evidence that sexual determination is the result of a normative choice. One of the key contributions of the paper to scholarly literature on Canguilhem is a better understanding of his notion of choice, which was considered not the conscious and intentional act of a subject but rather an axiological activity of the living. We conclude by positioning Canguilhem’s concept of normativity and his belief that norms are produced by the living in relation to the naturalist/normativist divide in medicine

    SiPM and front-end electronics development for Cherenkov light detection

    Full text link
    The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6Ă—\times6 mm2^2. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1Ă—\times1 mm2^2, 3Ă—\times3 mm2^2, and 6Ă—\times6 mm2^2 NUV SiPMs coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    Characterization and possible astrophysics applications of UV sensitive SiPM devices

    Get PDF
    The National Institute of Nuclear Physics (INFN) is involved in the R&D of Silicon Photomultiplier (SiPM) sensors optimized to detect near-UV (NUV) photon radiation in low-intensity photons and high-precision time mesaurements, in collaboration with the Bruno Kessler Foundation (FBK). The performances of 6Ă—6 mm2 NUV-HD SiPMs with 30Ă—30 ÎĽm2 microcell area and the possible prospects for production and packaging of multi-sensor modules for astrophysical applications are discussed in this paper

    Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data

    Full text link
    The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m2^2. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements

    INFN Camera demonstrator for the Cherenkov Telescope Array

    Get PDF
    The Cherenkov Telescope Array is a world-wide project for a new generation of ground-based Cherenkov telescopes of the Imaging class with the aim of exploring the highest energy region of the electromagnetic spectrum. With two planned arrays, one for each hemisphere, it will guarantee a good sky coverage in the energy range from a few tens of GeV to hundreds of TeV, with improved angular resolution and a sensitivity in the TeV energy region better by one order of magnitude than the currently operating arrays. In order to cover this wide energy range, three different telescope types are envisaged, with different mirror sizes and focal plane features. In particular, for the highest energies a possible design is a dual-mirror Schwarzschild-Couder optical scheme, with a compact focal plane. A silicon photomultiplier (SiPM) based camera is being proposed as a solution to match the dimensions of the pixel (angular size of ~ 0.17 degrees). INFN is developing a camera demonstrator made by 9 Photo Sensor Modules (PSMs, 64 pixels each, with total coverage 1/4 of the focal plane) equipped with FBK (Fondazione Bruno Kessler, Italy) Near UltraViolet High Fill factor SiPMs and Front-End Electronics (FEE) based on a Target 7 ASIC, a 16 channels fast sampler (up to 2GS/s) with deep buffer, self-trigger and on-demand digitization capabilities specifically developed for this purpose. The pixel dimensions of 6Ă—66\times6 mm2^2 lead to a very compact design with challenging problems of thermal dissipation. A modular structure, made by copper frames hosting one PSM and the corresponding FEE, has been conceived, with a water cooling system to keep the required working temperature. The actual design, the adopted technical solutions and the achieved results for this demonstrator are presented and discussed.Comment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    ps8 161 the disease burden in patients with longstanding systemic lupus erythematosus focus on health resource use and costs

    Get PDF
    Introduction As a consequence of increased SLE patients survival, patients with long disease duration represent a significant proportion of our cohorts. This study aims to evaluate health resource use and the 6 months costs in patients with SLE with long disease duration. Methods The economic evaluation was performed in terms of cost-of-illness analysis as part of a larger study enrolling SLE patients with at least 15 years of disease duration regularly followed at our unit. At enrollment, the following information were collected: disease activity (SLEDAI), organ damage (SLICC-DI score), comorbidities, treatment patterns; in addition to clinical data, patients were required to complete an ad-hoc questionnaire for the collection of facts relevant for the estimation of the economic dimension and covering the previous six-months. Such a time frame was considered to be appropriate as recall period. Direct health (drugs, hospitalizations, emergency visits, specialists visits, laboratory tests and instrumental examination) and non-health costs (transportation and accommodation) as well as indirect costs because of productivity loss were estimated. Results 51 adult patients with long disease duration were recruited (98% female, mean age 49±11 years, median disease duration 17 years, IQR 15–23). Median (IQR) SLEDAI score was 2 (0–4), median SLICC-DI was 1 (0–2). The median (IQR) direct health costs per patients over the previous 6 months resulted 410€ (201–1687); indirect costs because of productivity lost were 130€ (0–356). The median overall cost to the Society was 473€ (327–2148); the presence of comorbid conditions resulted associated with higher overall cost for the Society (552€ [327–1807] vs 264€ [94–1164] p=0.046); disease activity and damage at enrollment were not associated with costs increase in this cohort. Conclusions This cohort of patients with long lasting disease is characterised by low disease activity and mild organ damage; in this setting, the disease burden on the single patient and family is significant and the costs to the Society are influenced by the presence of comorbidities
    • …
    corecore