94 research outputs found

    Intra-laboratory assessment of a method for the detection of TiO2 nanoparticles present in sunscreens based on multi-detector asymmetrical flow field-flow fractionation

    Get PDF
    In this study, an intra-laboratory assessment was carried out to establish the effectiveness of a method for the detection of TiO2 engineered nanoparticles (ENPs) present in sunscreen containing nano-scale TiO2 and a higher nanometer-range (approx. 200-500 nm) Ti02, as well as iron oxide particles. Three replicate measurements were performed on five separate days to generate the measurement uncertainties associated with the quantitative asymmetrical flow field-flow fractionation (AF4) measurement of the hydrodynamic radius r(h, mode1) (MALS), rh,,odei (ICP-MS), r(h, mode2) (ICP-MS), and calculated mass-based particle size distribution (d(10), d(50), d(90)). The validation study demonstrates that the analysis of TiO2 ENPs present in sunscreen by AF4 separation-multi detection produces quantitative data (mass-based particle size distribution) after applying the sample preparation method developed within the NanoDefine project with uncertainties based on the precision (u(IP)) of 3.9-8.8%. This method can, therefore, be considered as the method with a good precision. Finally, the bias data shows that the trueness of the method (u(t) = 5.5-52%) can only be taken as a proxy due to the lack of a sunscreen standard containing certified TiO2 ENPs

    A critical evaluation of short columns for estimating the attachment efficiency of engineered nanomaterials in natural soils

    Get PDF
    Short, saturated packed columns are used frequently to estimate the attachment efficiency (alpha) of engineered nanomaterials (ENMs) in relatively homogeneous porous media, but a combined experimental and theoretical approach to obtain alpha-values for heterogeneous natural soils has not yet been agreed upon. Accurately determined alpha-values that can be used to study and predict ENM transport in natural soils should vary with ENM and soil properties, but not with experimental settings. We investigated the effect of experimental conditions, and used different methods to obtain soil parameters, essential to calculate alpha. We applied 150 different approaches to determine alpha-values from 52 transport experiments using short columns with 5 different natural soils and 20 and 80 nm gold- or 27 nm silver sulphide ENMs. The choice of column end-filter material and pore size appeared critical to avoid overestimating alpha owing to filter - ENM interactions and/or incomplete saturation of the column. Using a low ionic strength (4.4 x 10-5 mol L-1) artificial rain water as an aqueous medium avoided ENM homo- or heteroaggregation in all soils, as confirmed by single-particle inductively coupled plasma - time of flight mass spectrometry. ENM breakthrough curves could be modelled using colloid filtration theory assuming irreversible attachment only. alpha-Values calculated from this model, having the grain size represented by a single average size, accounting for dispersivity and effective porosity based on a prior inert tracer test, explained up to 42% of the variance in alpha as revealed by partial least squares analysis. However, column length and dispersivity remained as important experimental parameters, which calls for further standardisation efforts of column tests with ENMs in natural soils, preferably cross-validated with batch tests

    First steps towards a generic sample preparation scheme for inorganic engineered nanoparticles in a complex matrix for detection, characterization, and quantification by asymmetric flow-field flow fractionation coupled to multi-angle light scattering and ICP-MS

    Get PDF
    The applicability of a multi-step generic procedure to systematically develop sample preparation methods for the detection, characterization, and quantification of inorganic engineered nanoparticles (ENPs) in a complex matrix was successfully demonstrated. The research focused on the optimization of the sample preparation, aiming to achieve a complete separation of ENPs from a complex matrix without altering the ENP size distribution and with minimal loss of ENPs. The separated ENPs were detected and further characterized in terms of particle size distribution and quantified in terms of elemental mass content by asymmetric flow-field flow fractionation coupled to a multi-angle light scattering detector and an inductively coupled plasma mass spectrometer. Following the proposed generic procedure SiO2-ENPs were separated from a tomato soup. Two potential sample preparation methods were tested these being acid digestion and colloidal extraction. With the developed method a complete SiO2-ENPs and matrix separation with a Si mass recovery >90% was achieved by acid digestion. The alteration of the particle size distribution was minimized by particle stabilization. The generic procedure which also provides quality criteria for method development is urgently needed for standardized and systematic development of procedures for separation of ENPs from a complex matrix. The chosen analytical technique was shown to be suitable for detecting SiO2-ENPs in a complex food matrix like tomato soup and may therefore be extended to monitor the existence of ENPs during production and safety control of foodstuffs, food labelling, and compliance with legislative limits

    Quantification and Characterization of Nanoparticulate Zinc in an Urban Watershed

    Get PDF
    The recent expansion in the use of nanomaterials in consumer and industrial applications has led to a growing concern over their behavior, fate, and impacts in environmental systems. However, engineered nanoparticles comprise only a small fraction of the total nanoparticle mass in aquatic systems. Human activities, particularly in urban watersheds, are increasing the population of incidental nanoparticles and are likely altering the cycling of more abundant natural nanoparticles. Accurate detection, quantification, characterization, and tracking of these different populations is important for assessing both the ecological risks of anthropogenic particles, and their impact on environmental health. The urban portion of the South Platte watershed in Denver, Colorado (United States) was sampled for zinc to identify and quantify different nanomaterial sources. Single particle ICP-QMS was employed, to provide single elemental (Zn) signals arising from particle detection events. Coupling spICP-QMS to sample pre-fractionation (sedimentation, filtration) provided some insights into Zn association with nanoparticulate, colloidal, and suspended sediment phases. Single particle ICP-TOFMS (spICP-TOFMS) provided quantification across a large atomic mass range, yielding an even more detailed characterization (elemental ratios) on a particle-by-particle basis, providing some delineation of multiple sources of particles. Across the watershed, on average, 21% of zinc mass was present as zinc-only particles with a rather uniform mean size of 40.2 nm. Zinc that was detected with one or more other elements, primarily Al, Fe, and Si, is likely to be present as heteroagglomerates or within mineral colloids. Although spICP-TOFMS provides a substantial amount of information, it is still in its early stages as an analytical technique and currently lacks the requisite sensitivity to study the smallest of nanoparticles. As this technique continues to develop, it is anticipated that this methodology can be broadly applied to study sources, behavior and effects of a disparate variety of nanoparticles from both geogenic and anthropogenic origins

    Results of an interlaboratory comparison for characterization of Pt nanoparticles using single-particle ICP-TOFMS

    Get PDF
    This study describes an interlaboratory comparison (ILC) among nine (9) laboratories to evaluate and validate the standard operation procedure (SOP) for single-particle (sp) ICP-TOFMS developed within the context of the Horizon 2020 project ACEnano. The ILC was based on the characterization of two different Pt nanoparticle (NP) suspensions in terms of particle mass, particle number concentration, and isotopic composition. The two Pt NP suspensions were measured using icpTOF instruments (TOFWERK AG, Switzerland). Two Pt NP samples were characterized and mass equivalent spherical sizes (MESSs) of 40.4 ± 7 nm and 58.8 ± 8 nm were obtained, respectively. MESSs showed <16% relative standard deviation (RSD) among all participating labs and <4% RSD after exclusion of the two outliers. A good agreement was achieved between the different participating laboratories regarding particle mass, but the particle number concentration results were more scattered, with <53% RSD among all laboratories, which is consistent with results from previous ILC studies conducted using ICP-MS instrumentation equipped with a sequential mass spectrometer. Additionally, the capabilities of sp-ICP-TOFMS to determine masses on a particle basis are discussed with respect to the potential for particle density determination. Finally, because quasi-simultaneous multi-isotope and multi-element determinations are a strength of ICP-TOFMS instrumentation, the precision and trueness of isotope ratio determinations were assessed. The average of 1000 measured particles yielded a precision of below ±1% for intensity ratios of the most abundant Pt isotopes, i.e.194Pt and 195Pt, while the accuracy of isotope ratios with the lower abundant isotopes was limited by counting statistics

    Concern-Driven Integrated Toxicity Testing Strategies for Nanomaterials - Report of the NanoSafety Cluster Working Group 10

    Get PDF
    Bringing together topic-related European Union-(EU)-funded projects, the so-called “NanoSafety Cluster” aims at identifying key areas for further research on risk assessment procedures for nanomaterials (NM). The outcome of NanoSafety Cluster Working Group 10, this commentary presents a vision for concern-driven integrated approaches for the (eco-)toxicological testing and assessment (IATA) of NM. Such approaches should start out by determining concerns, i.e. specific information needs for a given NM based on realistic exposure scenarios. Recognized concerns can be addressed in a set of tiers using standardized protocols for NM preparation and testing. Tier 1 includes determining physico-chemical properties, non-testing (e.g. structure activity relationships) and evaluating existing data. In tier 2, a limited set of in vitro and in vivo tests are performed that can either indicate that the risk of the specific concern is sufficiently known or indicate the need for further testing, including details for such testing. Ecotoxicological testing begins with representative test organisms followed by complex test systems. After each tier, it is evaluated whether the information gained permits assessing the safety of the NM so that further testing can be waived. By effectively exploiting all available information, IATA allow accelerating the risk assessment process and reducing testing costs and animal use (in line with the 3Rs principle implemented in EU Directive 2010/63/EU). Combining material properties, exposure, biokinetics, and hazard data, information gained with IATA can be used to recognize groups of NM based upon similar modes-of-action. Grouping of substances in return should form integral part of the IATA themselves
    corecore