2 research outputs found

    Fasciculus rerum scholasticarum Collegii Claudiopolitani Unitariorum, 1626-1696 : 1. Journals of the years 1626-1648

    Get PDF
    We studied the effects of preconceptional exposure to multiwalled carbon nanotubes (MWCNTs): mature, female C57BL/6J mice were intratracheally instilled with 67 mu g NM-400 MWCNT, and the following day co-housed with mature males, in breeding pairs. Time to delivery of the first litter, litter parameters, maternal inflammation and histopathology of lung and liver were recorded. In male offspring, locomotor activity, startle response, and daily sperm production (DSP) were assessed. In the dams, lung and liver bore evidence of MWCNT exposure when assessed 6 weeks and 4 months after exposure. A short delay in the delivery of the first litter was observed in exposed females. Litter parameters, behavior and DSP were similar in control and exposed groups. In conclusion, instillation of a single dose of MWCNT induced long lasting pathological changes in dam lung and liver. Theoretically, lung inflammation due to particle exposure could interfere with female reproductive parameters. Whether the observed lag in delivery of a first litter was in fact caused by exposure to MWCNT should be addressed in a study designed specifically to elucidate effects on the early processes involved in establishment of pregnancy. Exposure was not associated with changes in the assessed gestational or offspring parameters

    Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

    No full text
    This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb-1 of LHC proton–proton collision data taken at centre-of-mass energies of (Equation Present) and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV
    corecore