77 research outputs found

    A Composite Metric for Benchmarking Site Performance in TAVR: Results from the STS/ACC TVT Registry

    Get PDF
    Background: Transcatheter aortic valve replacement (TAVR) is a transformative therapy for aortic stenosis. Despite rapid improvements in technology and techniques, serious complications remain relatively common and are not well described by single outcome measures. The purpose of this study was to determine if there is site-level variation in TAVR outcomes in the United States using a novel 30-day composite measure. Methods: We performed a retrospective cohort study using data from the STS/ACC TVT Registry to develop a novel ranked composite performance measure that incorporates mortality and serious complications. The selection and rank order of the complications for the composite was determined by their adjusted association with 1-year outcomes. Sites whose risk-adjusted outcomes were significantly more or less frequent than the national average based on a 95% probability interval were classified as performing worse or better than expected. Results: The development cohort consisted of 52,561 patients who underwent TAVR between January 1, 2015 and December 31, 2017. Based on the associations with 1-year risk-adjusted mortality and health status, we identified four periprocedural complications to include in the composite risk model in addition to mortality. Ranked empirically according to severity, these included stroke, major, life-threatening or disabling bleeding, stage III acute kidney injury, and moderate or severe peri-valvular regurgitation. Based on these ranked outcomes, we found that there was significant site-level variation in quality of care in TAVR in the United States. Overall, better than expected site performance was observed in 25/301 (8%) of sites; performance as expected was observed in 242/301 sites (80%); and worse than expected performance was observed in 34/301 (11%) of sites. Thirty-day mortality, stroke, major, life-threatening or disabling bleeding, and moderate or severe peri-valvular leak were each substantially more common in sites with worse than expected performance as compared with other sites. There was good aggregate reliability of the model. Conclusions: There are substantial variations in the quality of TAVR care received in the United States, and 11% of sites were identified as providing care below the average level of performance. Further study is necessary to determine structural, process-related, and technical factors associated with high- and low-performing sites

    Initial Thoracic Endovascular Aortic Repair vs Medical Therapy for Acute Uncomplicated Type B Aortic Dissection

    Get PDF
    IMPORTANCE: Thoracic endovascular aortic repair (TEVAR) has increasingly been used for uncomplicated type B aortic dissection (uTBAD) despite limited supporting data. OBJECTIVE: To assess whether initial TEVAR following uTBAD is associated with reduced mortality or morbidity compared with medical therapy alone. DESIGN, SETTING, AND PARTICIPANTS: This cohort study included Centers for Medicare & Medicaid Services inpatient claims data for adults aged 65 years or older with index admissions for acute uTBAD from January 1, 2011, to December 31, 2018, with follow-up available through December 31, 2019. EXPOSURES: Initial TEVAR was defined as TEVAR within 30 days of admission for acute uTBAD. MAIN OUTCOMES AND MEASURES: Outcomes included all-cause mortality, cardiovascular hospitalizations, aorta-related and repeated aorta-related hospitalizations, and aortic interventions associated with initial TEVAR vs medical therapy. Propensity score inverse probability weighting was used. RESULTS: Of 7105 patients with eligible index admissions for acute uTBAD, 1140 (16.0%) underwent initial TEVAR (623 [54.6%] female; median age, 74 years [IQR, 68-80 years]) and 5965 (84.0%) did not undergo TEVAR (3344 [56.1%] female; median age, 76 years [IQR, 69-83 years]). Receipt of TEVAR was associated with region (vs South; Midwest: adjusted odds ratio [aOR], 0.66 [95% CI, 0.53-0.81]; P \u3c .001; Northeast: aOR, 0.63 [95% CI, 0.50-0.79]; P \u3c .001), Medicaid dual eligibility (aOR, 0.76; 95% CI, 0.63-0.91; P = .003), hypertension (aOR, 1.26; 95% CI, 1.03-1.54; P = .03), peripheral vascular disease (aOR, 1.24; 95% CI, 1.02-1.49; P = .03), and year of admission (2012, 2013, 2014, and 2015 were associated with greater odds of TEVAR compared with 2011). After inverse probability weighting, mortality was similar for the 2 strategies up to 5 years (hazard ratio [HR], 0.95; 95% CI, 0.85-1.06), as were aorta-related hospitalizations (HR, 1.12; 95% CI, 0.99-1.27), aortic interventions (HR, 1.01; 95% CI, 0.84-1.20), and cardiovascular hospitalizations (HR, 1.05; 95% CI, 0.93-1.20). In a sensitivity analysis that included deaths within the first 30 days, initial TEVAR was associated with lower mortality over a period of 1 year (adjusted HR [aHR], 0.86; 95% CI, 0.75-0.99; P = .03), 2 years (aHR, 0.85; 95% CI, 0.75-0.96; P = .008), and 5 years (aHR, 0.87; 95% CI, 0.80-0.96; P = .004). CONCLUSIONS AND RELEVANCE: In this study, 16.0% of patients underwent initial TEVAR within 30 days of uTBAD, and receipt of initial TEVAR was associated with hypertension, peripheral vascular disease, region, Medicaid dual eligibility, and year of admission. Initial TEVAR was not associated with improved mortality or reduced hospitalizations or aortic interventions over a period of 5 years, but in a sensitivity analysis that included deaths within the first 30 days, initial TEVAR was associated with lower mortality. These findings, along with cost-effectiveness and quality of life, should be assessed in a prospective trial in the US population

    Tricuspid Valve Academic Research Consortium Definitions for Tricuspid Regurgitation and Trial Endpoints.

    Get PDF
    Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options

    Tricuspid Valve Academic Research Consortium Definitions for Tricuspid Regurgitation and Trial Endpoints.

    Get PDF
    Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options

    Albiglutide and cardiovascular outcomes in patients with type 2 diabetes and cardiovascular disease (Harmony Outcomes): a double-blind, randomised placebo-controlled trial

    Get PDF
    Background: Glucagon-like peptide 1 receptor agonists differ in chemical structure, duration of action, and in their effects on clinical outcomes. The cardiovascular effects of once-weekly albiglutide in type 2 diabetes are unknown. We aimed to determine the safety and efficacy of albiglutide in preventing cardiovascular death, myocardial infarction, or stroke. Methods: We did a double-blind, randomised, placebo-controlled trial in 610 sites across 28 countries. We randomly assigned patients aged 40 years and older with type 2 diabetes and cardiovascular disease (at a 1:1 ratio) to groups that either received a subcutaneous injection of albiglutide (30–50 mg, based on glycaemic response and tolerability) or of a matched volume of placebo once a week, in addition to their standard care. Investigators used an interactive voice or web response system to obtain treatment assignment, and patients and all study investigators were masked to their treatment allocation. We hypothesised that albiglutide would be non-inferior to placebo for the primary outcome of the first occurrence of cardiovascular death, myocardial infarction, or stroke, which was assessed in the intention-to-treat population. If non-inferiority was confirmed by an upper limit of the 95% CI for a hazard ratio of less than 1·30, closed testing for superiority was prespecified. This study is registered with ClinicalTrials.gov, number NCT02465515. Findings: Patients were screened between July 1, 2015, and Nov 24, 2016. 10 793 patients were screened and 9463 participants were enrolled and randomly assigned to groups: 4731 patients were assigned to receive albiglutide and 4732 patients to receive placebo. On Nov 8, 2017, it was determined that 611 primary endpoints and a median follow-up of at least 1·5 years had accrued, and participants returned for a final visit and discontinuation from study treatment; the last patient visit was on March 12, 2018. These 9463 patients, the intention-to-treat population, were evaluated for a median duration of 1·6 years and were assessed for the primary outcome. The primary composite outcome occurred in 338 (7%) of 4731 patients at an incidence rate of 4·6 events per 100 person-years in the albiglutide group and in 428 (9%) of 4732 patients at an incidence rate of 5·9 events per 100 person-years in the placebo group (hazard ratio 0·78, 95% CI 0·68–0·90), which indicated that albiglutide was superior to placebo (p<0·0001 for non-inferiority; p=0·0006 for superiority). The incidence of acute pancreatitis (ten patients in the albiglutide group and seven patients in the placebo group), pancreatic cancer (six patients in the albiglutide group and five patients in the placebo group), medullary thyroid carcinoma (zero patients in both groups), and other serious adverse events did not differ between the two groups. There were three (<1%) deaths in the placebo group that were assessed by investigators, who were masked to study drug assignment, to be treatment-related and two (<1%) deaths in the albiglutide group. Interpretation: In patients with type 2 diabetes and cardiovascular disease, albiglutide was superior to placebo with respect to major adverse cardiovascular events. Evidence-based glucagon-like peptide 1 receptor agonists should therefore be considered as part of a comprehensive strategy to reduce the risk of cardiovascular events in patients with type 2 diabetes. Funding: GlaxoSmithKline

    Design of tunable band pass filter using barium strontium titanate (BST) thin films

    No full text
    Barium strontium titanate (Ba1-xSrxTiO3) thin films exhibit unique properties like high dielectric constant, voltage tunable permittivity and small loss tangent which make it attractive in applications of tunable microwave devices. Following are some of the areas where ferroelectrics are applied (1) Random Access Memories (FERAM\u27s) (2) Integrated optics switches, couplers and modulators (3) piezoelectric resonators (4) Capacitors (5) Oscillators and (6) tunable filter. An effort is made to study and characterize the properties of BST thin films and to design a tunable band pass filter using their unique properties like tunable permittivity and low loss tangent. Different EM structures of IDC\u27s (Inter Digital Capacitors) are designed, tested, characterized and an effort is made to optimize the design for high Quality Factor (Q). A tunable band pass filter is designed, fabricated and tested for 1.72GHz center frequency. This is one of the foremost efforts made to design a band pass filter with Coplanar Wave Guide (CPW) transmission line components and BST varactor devices. The total length of the filter is 2.3mm
    corecore