49 research outputs found

    Developmental programming in human umbilical cord vein endothelial cells following fetal growth restriction

    Get PDF
    Background: Fetal growth restriction (FGR) is associated with an increased susceptibility for various noncommunicable diseases in adulthood, including cardiovascular and renal disease. During FGR, reduced uteroplacental blood flow, oxygen and nutrient supply to the fetus are hypothesized to detrimentally influence cardiovascular and renal programming. This study examined whether developmental programming profiles, especially related to the cardiovascular and renal system, differ in human umbilical vein endothelial cells (HUVECs) collected from pregnancies complicated by placental insufficiency-induced FGR compared to normal growth pregnancies. Our approach, involving transcriptomic profiling by RNA-sequencing and gene set enrichment analysis focused on cardiovascular and renal gene sets and targeted DNA methylation assays, contributes to the identification of targets underlying long-term cardiovascular and renal diseases. Results: Gene set enrichment analysis showed several downregulated gene sets, most of them involved in immune or inflammatory pathways or cell cycle pathways. seven of the 22 significantly upregulated gene sets related to kidney development and four gene sets involved with cardiovascular health and function were downregulated in FGR (n = 11) versus control (n = 8). Transcriptomic profiling by RNA-sequencing revealed downregulated expression of LGALS1, FPR3 and NRM and upregulation of lincRNA RP5-855F14.1 in FGR compared to controls. DNA methylation was similar for LGALS1 between study groups, but relative hypomethylation of FPR3 and hypermethylation of NRM were present in FGR, especially in male offspring. Absolute differences in methylation were, however, small. Conclusion: This study showed upregulation of gene sets related to renal development in HUVECs collected from pregnancies complicated by FGR compared to control donors. The differentially expressed gene sets related to cardiovascular function and health might be in line with the downregulated expression of NRM and upregulated expression of lincRNA RP5-855F14.1 in FG

    Study protocol: population screening for colorectal cancer by colonoscopy or CT colonography: a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Colorectal cancer (CRC) is the second most prevalent type of cancer in Europe. Early detection and removal of CRC or its precursor lesions by population screening can reduce mortality. Colonoscopy and computed tomography colonography (CT colonography) are highly accurate exams and screening options that examine the entire colon. The success of screening depends on the participation rate. We designed a randomized trial to compare the uptake, yield and costs of direct colonoscopy population screening, using either a telephone consultation or a consultation at the outpatient clinic, versus CT colonography first, with colonoscopy in CT colonography positives.</p> <p>Methods and design</p> <p>7,500 persons between 50 and 75 years will be randomly selected from the electronic database of the municipal administration registration and will receive an invitation to participate in either CT colonography (2,500 persons) or colonoscopy (5,000 persons) screening. Those invited for colonoscopy screening will be randomized to a prior consultation either by telephone or a visit at the outpatient clinic. All CT colonography invitees will have a prior consultation by telephone. Invitees are instructed to consult their general practitioner and not to participate in screening if they have symptoms suggestive for CRC. After providing informed consent, participants will be scheduled for the screening procedure. The primary outcome measure of this study is the participation rate. Secondary outcomes are the diagnostic yield, the expected and perceived burden of the screening test, level of informed choice and cost-effectiveness of both screening methods.</p> <p>Discussion</p> <p>This study will provide further evidence to enable decision making in population screening for colorectal cancer.</p> <p>Trial registration</p> <p>Dutch trial register: NTR1829</p

    Survival After Uncomplicated EVAR in Octogenarians is Similar to the General Population of Octogenarians Without an Abdominal Aortic Aneurysm

    Get PDF
    Objective: Long term survival after endovascular aortic aneurysm repair (EVAR) in octogenarians remains unclear. This was evaluated by comparing octogenarians after EVAR with a matched group of octogenarians without an abdominal aortic aneurysm (AAA) from the Rotterdam Study (RS). The influence of complications after EVAR on survival was also studied with the aim of identifying risk factors for the development of complications in octogenarians. Methods: Using propensity score matching (PSM), 83 EVAR octogenarians were matched for comorbidities with 83 octogenarians from the RS, and survival was compared between these two groups using Cox proportional hazard analysis. Then, complications were studied, defined as cardiac or pulmonary, renal deterioration, access site bleeding, acute limb ischaemia or bowel ischaemia, within 30 days of surgery between 83 EVAR octogenarians and 475 EVAR non-octogenarians. Also, the difference in baseline characteristics between the octogenarians with and without complications after EVAR were studied, and survival was compared between the RS controls and the complicated and uncomplicated EVAR octogenarians separately. Results: The total EVAR octogenarian population did not show an increased mortality risk compared with RS octogenarian controls (hazard ratio [HR] 1.28, 95% confidence interval [CI] 0.84–1.97). Post-operative complications occurred in 22 octogenarians (27%) and 59 non-octogenarians (12.4%, p < .001), mainly cardiac, pulmonary, and bleeding complications. All baseline characteristics were similar in the complicated EVAR octogenarians compared with the uncomplicated EVAR octogenarians. After uncomplicated EVAR, octogenarians had a similar survival compared with the RS controls (HR 1.

    CT colonography with limited bowel preparation for the detection of colorectal neoplasia in an FOBT positive screening population

    Get PDF
    Item does not contain fulltextPURPOSE: Aim was to evaluate the accuracy of computed tomography colonography (CTC) for detection of colorectal neoplasia in a Fecal Occult Blood Test (FOBT) positive screening population. METHODS: In three different institutions, consecutive FOBT positives underwent CTC after laxative free iodine tagging bowel preparation followed by colonoscopy with segmental unblinding. Each CTC was read by two experienced observers. For CTC and for colonoscopy the per-polyp sensitivity and per-patient sensitivity and specificity were calculated for detection of carcinomas, advanced adenomas, and adenomas. RESULTS: In total 22 of 302 included FOBT positive participants had a carcinoma (7%) and 137 had an adenoma or carcinoma >/=10 mm (45%). CTC sensitivity for carcinoma was 95% with one rectal carcinoma as false negative finding. CTC sensitivity for advanced adenomas was 92% (95% CI: 88-96) vs. 96% (95% CI: 93-99) for colonoscopy (P = 0.26). For adenomas and carcinomas >/=10 mm the CTC per-polyp sensitivity was 93% (95% CI: 89-97) vs. 97% (95% CI: 94-99) for colonoscopy (P = 0.17). The per-patient sensitivity for the detection of adenomas and carcinomas >/=10 mm was 95% (95% CI: 91-99) for CTC vs. 99% (95% CI: 98-100) for colonoscopy (P = 0.07), while the per-patient specificity was 90% (95% CI: 86-95) and 96% (95% CI: 94-99), respectively (P < 0.001). CONCLUSION: CTC with limited bowel preparation performed in an FOBT positive screening population has high diagnostic accuracy for the detection of adenomas and carcinomas and a sensitivity similar to that of colonoscopy for relevant lesions.1 december 201

    A Multi-Platform Flow Device for Microbial (Co-) Cultivation and Microscopic Analysis

    Get PDF
    Novel microbial cultivation platforms are of increasing interest to researchers in academia and industry. The development of materials with specialized chemical and geometric properties has opened up new possibilities in the study of previously unculturable microorganisms and has facilitated the design of elegant, high-throughput experimental set-ups. Within the context of the international Genetically Engineered Machine (iGEM) competition, we set out to design, manufacture, and implement a flow device that can accommodate multiple growth platforms, that is, a silicon nitride based microsieve and a porous aluminium oxide based microdish. It provides control over (co-)culturing conditions similar to a chemostat, while allowing organisms to be observed microscopically. The device was designed to be affordable, reusable, and above all, versatile. To test its functionality and general utility, we performed multiple experiments with Escherichia coli cells harboring synthetic gene circuits and were able to quantitatively study emerging expression dynamics in real-time via fluorescence microscopy. Furthermore, we demonstrated that the device provides a unique environment for the cultivation of nematodes, suggesting that the device could also prove useful in microscopy studies of multicellular microorganisms

    Radiosensitizing potential of the selective cyclooygenase-2 (COX-2) inhibitor meloxicam on human glioma cells

    Get PDF
    The COX-2 protein is frequently overexpressed in human malignant gliomas. This expression has been associated with their aggressive growth characteristics and poor prognosis for patients. Targeting the COX-2 pathway might improve glioma therapy. In this study, the effects of the selective COX-2 inhibitor meloxicam alone and in combination with irradiation were investigated on human glioma cells in vitro. A panel of three glioma cell lines (D384, U87 and U251) was used in the experiments from which U87 cells expressed constitutive COX-2. The response to meloxicam and irradiation (dose-range of 0–6 Gy) was determined by the clonogenic assay, cell proliferation was evaluated by growth analysis and cell cycle distribution by FACS. 24–72 h exposure to 250–750 μM meloxicam resulted in a time and dose dependent growth inhibition with an almost complete inhibition after 24 h for all cell lines. Exposure to 750 μM meloxicam for 24 h increased the fraction of cells in the radiosensitive G2/M cell cycle phase in D384 (18–27%) and U251 (17–41%) cells. 750 μM meloxicam resulted in radiosensitization of D384 (DMF:2.19) and U87 (DMF:1.25) cells, but not U251 cells (DMF:1.08). The selective COX-2 inhibitor meloxicam exerted COX-2 independent growth inhibition and radiosensitization of human glioma cells

    Does CT colonography have a role for population-based colorectal cancer screening?

    Get PDF
    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. CRC screening has been proven to reduce disease-specific mortality and several European countries employ national screening programmes. These almost exclusively rely on stool tests, with endoscopy used as an adjunct in some countries. Computed tomographic colonography (CTC) is a potential screening test, with an estimated sensitivity of 88 % for advanced neoplasia ≥10 mm. Recent randomised studies have shown that CTC and colonoscopy have similar yields of advanced neoplasia per screened invitee, indicating that CTC is potentially viable as a primary screening test. However, the evidence is not fully elaborated. It is unclear whether CTC screening is cost-effective and the impact of extracolonic findings, both medical and economic, remains unknown. Furthermore, the effect of CTC screening on CRC-related mortality is unknown, as it is also unknown for colonoscopy. It is plausible that both techniques could lead to decreased mortality, as for sigmoidoscopy and gFOBT. Although radiation exposure is a drawback, this disadvantage may be over-emphasised. In conclusion, the detection characteristics and acceptability of CTC suggest it is a viable screening investigation. Implementation will depend on detection of extracolonic disease and health-economic impact
    corecore