47 research outputs found

    Influence of the relative humidity on the morphology of inkjet printed spots of IgG on a non-porous substrate

    Get PDF
    During the drying of inkjet printed droplets, the solute particles (IgG-Alexa-635 molecules) in the drop may distribute unevenly on the substrate, resulting in a coffee-stain spot morphology. In our study, we investigated the influence of the relative humidity on the distribution of inkjet printed fluorophore labeled IgG molecules on a polystyrene substrate. A theoretical model for an evaporating droplet was developed in order to predict the changes in the spot diameter, height and volume of a drying droplet. An experiment was performed where a sessile droplet was monitored using a CCD camera installed on a goniometer and good agreement was found between the experimental results and simulation data. We also compared the predicted morphology for an inkjet-printed microarray spot with the experimental results where IgG molecules were printed for various relative humidities. The spot morphology of the dried spots was analyzed by a confocal laser microscopy. At a lower relative humidity (i.e.

    Rapid antibody selection using surface plasmon resonance for high-speed and sensitive hazelnut lateral flow prototypes

    Get PDF
    Lateral Flow Immunoassays (LFIAs) allow for rapid, low-cost, screening of many biomolecules such as food allergens. Despite being classified as rapid tests, many LFIAs take 10–20 min to complete. For a really high-speed LFIA, it is necessary to assess antibody association kinetics. By using a label-free optical technique such as Surface Plasmon Resonance (SPR), it is possible to screen crude monoclonal antibody (mAb) preparations for their association rates against a target. Herein, we describe an SPR-based method for screening and selecting crude anti-hazelnut antibodies based on their relative association rates, cross reactivity and sandwich pairing capabilities, for subsequent application in a rapid ligand binding assay. Thanks to the SPR selection process, only the fast mAb (F-50-6B12) and the slow (S-50-5H9) mAb needed purification for labelling with carbon nanoparticles to exploit high-speed LFIA prototypes. The kinetics observed in SPR were reflected in LFIA, with the test line appearing within 30 s, almost two times faster when F-50-6B12 was used, compared with S-50-5H9. Additionally, the LFIAs have demonstrated their future applicability to real life samples by detecting hazelnut in the sub-ppm range in a cookie matrix. Finally, these LFIAs not only provide a qualitative result when read visually, but also generate semi-quantitative data when exploiting freely downloadable smartphone apps.</p

    Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays

    Get PDF
    Carbon nanoparticles (CNPs) labeled with reporter molecules can serve as signaling labels in rapid diagnostic assays as an alternative to gold, colored latex, silica, quantum dots, or up-converting phosphor nanoparticles. Detailed here is the preparation of biomolecule-labeled CNPs and examples of their use as a versatile label. CNPs can be loaded with a range of biomolecules, such as DNA, antibodies, and proteins (e.g., neutravidin or a fusion protein of neutravidin with an enzyme), and the resulting conjugates can be used to detect analytes of high or low molecular mass

    Rapid Methods for Biological and Chemical Contaminants in Food and Feed

    No full text
    The rapid and reliable detection of biological and chemical contaminants is extremely important in managing the safety of food and feed. Rapid Methods is a comprehensive reference source for anyone interested in this subject. Developments in analyticla techniques have led to the emergence of a wide range of rapid methods to complement the traditional methods. At the same time, the importance of method validation, proficiency testing, quality management, sampling and legislation have all become more widely recognised. Rapid Methods presents a firm base and structured framework for considering rapid analysis of biological and chemical contaminants in food and feed. The various chapters concentrate on the state of the art in rapid methods as regards to legislation, sampling, method validation, microbial pathogens, biological materials such as GMOs and allergens, toxins like bacterial food poisoning toxins, marine toxins and biogenic amines and chemicals like veterinary drugs, pesticides and dioxins. The nature of the theme, the excellence of the peer-reviewed papers and the holistic approach chosen in this book will draw an audience from both the food and the feed industry as well as from the scientific community.JRC.D.8-Food safety and qualit

    Influence of Pluronic F127 on the distribution and functionality of inkjet-printed biomolecules in porous nitrocellulose substrates

    Get PDF
    The distribution of inkjet-printed biomolecules in porous nitrocellulose substrates often results in a non-homogeneous spot morphology commonly referred to as 'doughnut-shaped' spots. We have studied the influence of Pluronic F127 (an amphiphilic surfactant) on the functionality of inkjet-printed primary antibody molecules and on the final assay result by performing a one-step antibody binding assay in the nitrocellulose substrate. The primary antibody was printed with and without Pluronic, followed by the addition of double-labelled amplicons as antigen molecules and a fluorophore-labelled streptavidin as detection conjugate. The distribution of the fluorescence intensity down into the nitrocellulose substrate was investigated by confocal laser scanning microscopy in 'Z' stacking mode. Each horizontal slice was further analysed by applying a concentric ring format and the fluorescence intensity in each slice was represented in a colour-coded way. The mean and total fluorescence intensity of the antibody binding assay (fluorescent streptavidin) showed a peak at 0.2% (w/v) Pluronic F127. In addition, an improved spot morphology was observed also peaking at the same Pluronic concentration. Subsequently, we investigated the direct influence of Pluronic F127 on the location of the primary antibody molecules by labelling these molecules with the fluorophore Alexa-488. Our results show that upon increasing the concentration of Pluronic F127 in the printing buffer, the spot diameter increased and the number of primary antibody molecules bound in the spot area gradually decreased. This was confirmed by analysing the distribution of fluorescently labelled primary antibody molecules down into the membrane layers. We conclude that a particular ratio between primary antibody and Pluronic F127 molecules in combination with available substrate binding capacity results in an optimal orientation, that is Fab-UP, of the primary antibody molecules. Consequently, an increased number of antigen molecules (in our case the labelled amplicons) and of the fluorescent detection conjugate (streptavidin) will give an optimal signal. Moreover, distribution of the primary antibody molecules was more homogeneous at the optimal Pluronic F127 concentration, contributing to the better spot morphology observed. (C) 2014 Elsevier B.V. All rights reserved

    Influence of buffer composition on the distribution of inkjet printed protein molecules and the resulting spot morphology

    No full text
    Producing high quality protein microarrays on inexpensive substrates like polystyrene is a big challenge in the field of diagnostics. Using a non-contact inkjet printer we have produced microarrays on polystyrene slides for two different biotinylated biomolecules, bovine serum albumin (BSA-biotin) and immunoglobulin-G (IgG-biotin), and studied the influence of buffer (composition and pH) on the spot morphology and signal intensity. Atomic force microscopy revealed the morphological pattern of the (biomolecule) spots printed from phosphate buffer (pH 7.4), phosphate buffered saline (pH 7.4) and carbonate buffer (pH 9.6). The spots showed an irregular crust-like appearance when printed in phosphate buffered saline (pH 7.4), mainly due to the high NaCl content, whereas spots of biomolecules printed in carbonate buffer (pH 9.6) showed a smooth morphology. In addition, the rinsing of these dried spots led to the loss of a considerable fraction of the biomolecules, leaving behind a small fraction that is compatible with the (mono)layer. It was confirmed by confocal laser microscopy that the quality of the spots with respect to the uniformity and distribution of the biomolecules therein was superior when printed in carbonate buffer (pH 9.6) as compared to other buffer systems. Particularly, spotting in PBS yielded spots having a very irregular distribution and morphology. (C) 2012 Elsevier B.V. All rights reserved

    Spot morphology of non-contact printed protein molecules on non-porous substrates with a range of hydrophobicities

    No full text
    <p>Non-contact inkjet printing technology is one of the most promising tools for producing microarrays. The quality of the microarray depends on the type of the substrate used for printing biomolecules. Various porous and non-porous substrates have been used in the past, but due to low production cost and easy availability, non-porous substrates like glass and plastic are preferred over porous substrates. On these non-porous substrates, obtaining spot uniformity and a high signal to noise ratio is a big challenge. In our research work, we have modified pristine glass slides using various silanes to produce a range of hydrophobic glass substrates. The hydrophobicities of the slides expressed in the contact angle (theta) of a sessile drop of water were 49 degrees, 61 degrees, 75 degrees, 88 degrees and 103 degrees. Using a non-contact inkjet printer, microarrays of biotinylated biomolecules (BSA and IgG) were produced on these modified glass substrates, pristine (untreated) glass and also on HTA polystyrene slides. The uniformity of the spots, reflecting the distribution of the biomolecules in the spots, was analyzed and compared using confocal laser scanning microscopy (CLSM). The quality of the spots was superior on the glass slide with a contact angle of similar to 75 degrees. We also investigated the influence of the hydrophobicity of the substrate on a two-step, real diagnostic antibody assay. This nucleic acid microarray immunoassay (NAMIA) for the detection of Staphylococcus aureus showed that on highly hydrophilic (theta <10 degrees) and hydrophobic substrates (theta > 100 degrees) the assay signal was low, whereas an excellent signal was obtained on the substrates with intermediate contact angles, theta similar to 61 degrees and theta similar to 75 degrees, respectively.</p>
    corecore