6,647 research outputs found

    Base de dados geográficos como subsídio à gestão territorial na fazenda experimental da Embrapa Amazônia Oriental, Belém, PA.

    Get PDF
    bitstream/item/61586/1/CPATU-BPD77.pdfAnexo 4 mapas: Solos da Fazenda Experimental da Embrapa Amazônia Oriental, Belém, PA; Uso atual das terras da Fazenda Experimental da Embrapa Amazônia Oriental, Belém, PA; Restrição legal ao uso da terra da Fazenda Experimental da Embrapa Amazônia Oriental, Belém, PA.Zoneamento agroecológico da Fazenda Experimental da Embrapa Amazônia Oriental, Belém, PA

    Characterization of the water diffusion in GEM foil material

    Get PDF
    Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level.These studies are important because the presence of this compound inside the detector’s foil can possibly change its mechanical and electrical properties,and in such a way,the detector performance can be affected.To understand this phenomenon,a model is developed with COMSOL Multiphysicsv.4.3 which described the adsorption and diffusion within the geometry of GEM foil,the concentration profiles and the time required to saturate the foil.The COMSOL model is verified by experimental observations on a GEM foil sample.This note will describe the model and its experimental verification results

    A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns

    Get PDF
    Objectives: The aim of the present systematic review was to analyze the survival and complication rates of zirconia-based and metal-ceramic implant-supported single crowns (SCs). Materials and Methods: An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort and retrospective case series on implant-supported SCs with a mean follow-up time of at least 3 years. Patients had to have been clinically examined at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. Results: The search provided 5,263 titles and 455 abstracts, full-text analysis was performed for 240 articles, resulting in 35 included studies on implant-supported crowns. Meta-analysis revealed an estimated 5-year survival rate of 98.3% (95% CI: 96.8–99.1) for metal-ceramic implant supported SCs (n = 4,363) compared to 97.6% (95% CI: 94.3–99.0) for zirconia implant supported SCs (n = 912). About 86.7% (95% CI: 80.7–91.0) of the metal-ceramic SCs (n = 1,300) experienced no biological/technical complications over the entire observation period. The corresponding rate for zirconia SCs (n = 76) was 83.8% (95% CI: 61.6–93.8). The biologic outcomes of the two types of crowns were similar; yet, zirconia SCs exhibited less aesthetic complications than metal-ceramics. The 5-year incidence of chipping of the veneering ceramic was similar between the material groups (2.9% metal-ceramic, 2.8% zirconia-ceramic). Significantly (p = 0.001), more zirconia-ceramic implant SCs failed due to material fractures (2.1% vs. 0.2% metal-ceramic implant SCs). No studies on newer types of monolithic zirconia SCs fulfilled the simple inclusion criteria of 3 years follow-up time and clinical examination of the present systematic review. Conclusion: Zirconia-ceramic implant-supported SCs are a valid treatment alternative to metal-ceramic SCs, with similar incidence of biological complications and less aesthetic problems. The amount of ceramic chipping was similar between the material groups; yet, significantly more zirconia crowns failed due to material fractures

    A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses

    Get PDF
    Objectives: The aim of the present review was to compare the outcomes, that is, survival and complication rates of zirconia-ceramic and/or monolithic zirconia implant-supported fixed dental prostheses (FDPs) with metal-ceramic FDPs. Materials and Methods: An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort studies and retrospective case series on implant-supported FDPs with a mean follow-up of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson regression models to obtain summary estimates of 5-year proportions. Results: The search provided 5,263 titles and 455 abstracts. Full-text analysis was performed for 240 articles resulting in 19 studies on implant FDPs that met the inclusion criteria. The studies reported on 932 metal-ceramic and 175 zirconia-ceramic FDPs. Meta-analysis revealed an estimated 5-year survival rate of 98.7% (95% CI: 96.8%–99.5%) for metal-ceramic implant-supported FDPs, and of 93.0% (95% CI: 90.6%–94.8%) for zirconia-ceramic implant-supported FDPs (p < 0.001). Thirteen studies including 781 metal-ceramic implant-supported FDPs estimated a 5-year rate of ceramic fractures and chippings to be 11.6% compared with a significantly higher (p < 0.001) complication rate for zirconia implant-supported FDPs of 50%, reported in a small study with 13 zirconia implant-supported FDPs. Significantly (p = 0.001) more, that is, 4.1%, of the zirconia-ceramic implant-supported FDPs were lost due to ceramic fractures compared to only 0.2% of the metal-ceramic implant-supported FDPs. Detailed analysis of factors like number of units of the FDPs or location in the jaws was not possible due to heterogeneity of reporting. No studies on monolithic zirconia implant-supported FDPs fulfilled the inclusion criteria of the present review. Furthermore, no conclusive results were found for the aesthetic outcomes of both FDP-types. Conclusion: For implant-supported FDPs, conventionally veneered zirconia should not be considered as material selection of first priority, as pronounced risk for framework fractures and chipping of the zirconia veneering ceramic was observed. Monolithic zirconia may be an interesting alternative, but its clinical medium- to long-term outcomes have not been evaluated yet. Hence, metal ceramics seems to stay the golden standard for implant-supported multiple-unit FDPs

    Plasma Treatment of Bulk Niobium Surfaces for SRF Cavities

    Get PDF
    Two types of electric discharges were used to demonstrate the validity of plasma surface treatment for superconducting radio-frequency (SRF) cavities. The experiments were performed on disc-shaped Nb samples and compared with identical samples treated with buffer chemical polishing (BCP) techniques. Surface analysis indicates comparable or superior properties of plasma-treated samples. These promising results are still preliminary and additional work is in progress

    ALDEHYDE EMISSIONS FROM A STATIONARY DIESEL ENGINE OPERATING WITH CASTOR OIL BIODIESEL – DIESEL OIL BLENDS

    Get PDF
    The presence of aldehyde in the exhaust gas of a stationary, direct injection, compression ignition engine operating with castor oil biodiesel/diesel oil blends (B5, B10, B20 and B35) is analyzed. The diesel engine was operated with constant speed of 1800 rev/min and load of 37.5 kW. The gas sample was collected directly from the exhaust. Aldehydes were identified and quantified using gas chromatography (GC) with flame ionization detector analyzer (FID). Acetaldehyde presented higher exhaust concentration than formaldehyde for all fuel blends tested. In general, the exhaust aldehyde levels were very low and did not present significant differences between the fuel blends tested

    Síncope e Padrão de Brugada Intermitente

    Get PDF
    A síndrome de Brugada é uma síndrome rara, com uma prevalência aproximada na Europa de 1-5/10 000 habitantes, mas cuja apresentação clínica inicial pode ser morte súbita. Embora com um padrão eletrocardiográfico típico, este é por vezes intermitente. Os autores apresentam o caso clínico de um doente de sexo masculino, de 32 anos, sem fatores de risco pessoais conhecidos e história familiar de morte súbita, que recorre ao Serviço de Urgência por síncope sem pródromos. O primeiro eletrocardiograma (ECG) em ritmo sinusal documenta a presença de uma elevação isolada e inespecífica do segmento ST em V2. Da restante investigação diagnóstica realizada, salienta-se a repetição do ECG, que revelou a presença de padrão de Brugada tipo 1. Este mesmo padrão é exacerbado posteriormente numa situação de infeção respiratória. O doente foi submetido a estudo eletrofisiológico, seguido de implantação de cardiodesfibrilhador (CDI), tendo tido um episódio de fibrilhação ventricular convertido com choque via CDI 2 meses após a implantação

    Nonlinear magneto-optical rotation of frequency-modulated light resonant with a low-J transition

    Full text link
    A low-light-power theory of nonlinear magneto-optical rotation of frequency-modulated light resonant with a J=1->J'=0 transition is presented. The theory is developed for a Doppler-free transition, and then modified to account for Doppler broadening and velocity mixing due to collisions. The results of the theory are shown to be in qualitative agreement with experimental data obtained for the rubidium D1 line.Comment: 11 pages, 5 figures, v.2 edited for clarit

    Composição químico-bromatológica, digestibilidade e degradação in situ da dieta de ovinos em capim-tanzânia sob três frequências de desfolhação.

    Get PDF
    Objetivou-se avaliar a composição químico-bromatológica, a digestibilidade e a degradação in situ da matéria seca da dieta consumida por ovinos em pastagem de Panicum maximum cv. tanzânia sob três frequências de desfolhação, determinadas pela interceptação da radiação fotossinteticamente ativa (IRFA) de 85, 95 e 97% no 1o e 4o dias de pastejo. O delineamento experimental foi inteiramente casualizado com arranjo fatorial 3 × 2 (três frequências de desfolhação e dois dias de pastejo), com quatro repetições (piquetes) por tratamento. Para determinação da composição químico-bromatológica e da digestibilidade e ensaio de cinética de degradação da matéria seca da dieta, foi realizada uma simulação de pastejo no 1o e 4o dias de ocupação. A diminuição da frequência de desfolhação piorou a composição químico-bromatológica, a digestibilidade e a degradação do capim-tanzânia. Recomenda-se frequência de desfolhação no capim-tanzânia menor ou igual a 95% de interceptação da radiação fotossinteticamente ativa visando à manutenção da qualidade do pasto
    corecore