15,559 research outputs found

    An educational distributed Cosmic Ray detector network based on ArduSiPM

    Full text link
    The advent of microcontrollers with enough CPU power and with analog and digital peripherals makes possible to design a complete particle detector with relative acquisition system around one microcontroller chip. The existence of a world wide data infrastructure as internet allows for devising a distributed network of cheap detectors capable to elaborate and send data or respond to settings commands. The internet infrastructure enables to distribute the absolute time (with precision of few milliseconds), to the simple devices far apart, with few milliseconds precision, from a few meters to thousands of kilometres. So it is possible to create a crowdsourcing experiment of citizen science that use small scintillation-based particle detectors to monitor the high energetic cosmic ray and the radiation environment

    Cultivating diversity and food quality. Proceedings of Diversifood EU Forum, Brussels, 11 April 2018

    Get PDF
    To tackle this issue, Diversifood team organised a forum with policy makers and stakeholders on the 11th of April 2018, in Brussels. Diversifood’s aim is to share results and key lessons including new approaches for the management of cultivated biodiversity, for plant breeding for sustainable farming systems, and new relationships among actors of food systems. In the afternoon, there was time for discussion, knowledge sharing, collecting feedback and extending current policies to include cultivating diversity and food quality (for FP9, CAP 2020, The outputs of this workshop will feed Diversifood’s final recommendations. The forum was kindly hosted by the European Committee of the Regions (Rue Belliard/Belliardstraat 101, 1040 Brussels)

    The mm-dissimilarity map and representation theory of SLmSL_m

    Get PDF
    We give another proof that mm-dissimilarity vectors of weighted trees are points on the tropical Grassmanian, as conjectured by Cools, and proved by Giraldo in response to a question of Sturmfels and Pachter. We accomplish this by relating mm-dissimilarity vectors to the representation theory of SLm.SL_m.Comment: 11 pages, 8 figure

    The organic seed regulations framework in Europe – current status and recommendations for future development

    Get PDF
    Organic agriculture regulations, in particular European regulation EC 889/2008, prescribe the use of organically produced seed. For many cultivated plants, however, organic seed is often not available. This is mainly because investment in organic plant breeding and seed production has been low in the past. To bridge the gap between organic seed supply and demand, national and European regulations define certain circumstances under which organic producers are permitted to use non-organically produced seed. While the organic sector currently depends on these concessions, they also threaten to impede a further increase in the demand for organic seed, thereby potentially restraining present and future investment in organic seed production and plant breeding. We review the current status of the organic seed regulations framework by analysing key issues such as the role of the national derogation regimes, the role of expert groups, databases and seed prices. Key points are that (a) the situation of the organic seed sector has improved over the last few years; however, (b) reporting on organic seed to the EU by different countries needs to be harmonised; (c) the success of the organic seed sector depends critically on the implementation and improvement of national expert groups; and (d) to protect genetic diversity, the use of local varieties and landraces should not be impeded by organic seed regulations

    Use of bremsstrahlung radiation to identify hidden weak beta- sources: feasibility and possible use in radio-guided surgery

    Full text link
    The recent interest in beta- radionuclides for radio-guided surgery derives from the feature of the beta radiation to release energy in few millimeters of tissue. Such feature can be used to locate residual tumors with a probe located in its immediate vicinity, determining the resection margins with an accuracy of millimeters. The drawback of this technique is that it does not allow to identify tumors hidden in more than few mm of tissue. Conversely, the bremsstrahlung X-rays emitted by the interaction of the beta- radiation with the nuclei of the tissue are relatively penetrating. To complement the beta- probes, we have therefore developed a detector based on cadmium telluride, an X-ray detector with a high quantum efficiency working at room temperature. We measured the secondary emission of bremsstrahlung photons in a target of Polymethylmethacrylate (PMMA) with a density similar to living tissue. The results show that this device allows to detect a 1 ml residual or lymph-node with an activity of 1 kBq hidden under a layer of 10 mm of PMMA with a 3:1 signal to noise, i.e. with a five sigma discrimination in less than 5 s

    First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation

    Full text link
    Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex-vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. Methods: A patient affected by meningioma was administered 300 MBq of 90Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a beta- probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. Results: we obtained a large signal on the bulk tumor (105 cps) and a significant signal on residuals of \sim0.2 ml (28 cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (~1 cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. Conclusions: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.Comment: 17 pages, 4 Figs, Accepted by Physica Medic

    Dependence of the energy resolution of a scintillating crystal on the readout integration time

    Get PDF
    The possibilty of performing high-rate calorimetry with a slow scintillating crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted light, thus spoiling the energy resolution. This effect was experimentally studied with a BGO crystal and a photomultiplier followed by an integrator, by measuring the maximum amplitude of the signals. The experimental data show that the energy resolution is exclusively due to the statistical fluctuations of the number of photoelectrons contributing to the maximum amplitude. When such number is small its fluctuations are even smaller than those predicted by Poisson statistics. These results were confirmed by a Monte Carlo simulation which allows to estimate, in a general case, the energy resolution, given the total number of photoelectrons, the scintillation time and the integration time

    Performance of the LHCb muon system with cosmic rays

    Full text link
    The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber efficiency, time resolution and cluster size are described in detail. The results are in agreement with the expected detector performance.Comment: Submitted to JINST and accepte
    corecore