125 research outputs found

    Photoacoustic imaging in biomedicine and life sciences

    Get PDF
    Photo-acoustic imaging, also known as opto-acoustic imaging, has become a widely popular modality for biomedical applications. This hybrid technique possesses the advantages of high optical contrast and high ultrasonic resolution. Due to the distinct optical absorption properties of tissue compartments and main chromophores, photo-acoustics is able to non-invasively observe structural and functional variations within biological tissues including oxygenation and deoxygenation, blood vessels and spatial melanin distribution. The detection of acoustic waves produced by a pulsed laser source yields a high scaling range, from organ level photo-acoustic tomography to sub-cellular or even molecular imaging. This review discusses significant novel technical solutions utilising photo-acoustics and their applications in the fields of biomedicine and life sciences

    Performance and flow dynamics studies of polymeric optofluidic sers sensors

    Get PDF
    We present a polymer-based optofluidic surface enhanced Raman scattering chip for biomolecule detection, serving as a disposable sensorchoice with cost-effective production. The SERS substrate is fabricated by using industrial roll-to-roll UV-nanoimprinting equipment andintegrated with adhesive-based polymeric microfluidics. The functioning of the SERS detection on-chip is confirmed and the effect of thepolymer lid on the obtainable Raman spectra is analysed. Rhodamine 6G is used as a model analyte to demonstrate continuous flowmeasurements on a planar SERS substrate in a microchannel. The relation between the temporal response of the sensors and sample flowdynamics is studied with varied flow velocities, using SERS and fluorescence detection. The response time of the surface-dependent SERSsignal is longer than the response time of the fluorescence signal of the bulk flow. This observation revealed the effect of convection on thetemporal SERS responses at 25 μl/min to 1000 μl/min flow velocities. The diffusion of analyte molecules from the bulk concentration intothe sensing surface induces about a 40-second lag time in the SERS detection. This lag time, and its rising trend with slower flow velocities, has to be taken into account in future trials of the optofluidic SERS sensor, with active analyte binding on the sensing surface

    Evaluation of Heart Rate Variation Analysis during Rest and Tilting in Patients with Temporal Lobe Epilepsy

    Get PDF
    Objective. To evaluate spectral heart rate (HR) variation using short-term ECG recordings at rest and during the tilt table test. Methods. The values of spectral components of total power (TP), high-frequency power (HF), low-frequency power (LF) and LF: HF ratio were measured at rest and during the head-up tilt in patients with temporal lobe epilepsy (TLE) and their control subjects. Results. Compared to the control subjects, patients with TLE had lower HF (P < 0.05) and LF : HF ratio (P < 0.05) at rest and lower TP (P < 0.001), HF (P < 0.05), and LF (P < 0.05) during the head-up tilt. Upon changing from supine to standing position TP (P < 0.05) and LF (P < 0.05) were attenuated in patients with TLE compared to the control subjects. Conclusion. These results suggest that spectral analysis of HR variation from ECG recordings of short duration may add value to assessment of autonomic nervous system function using autonomic cardiac tests in patients with TLE

    Visualization of paper structure by optical coherence tomography: Monte Carlo simulations and experimental study

    Get PDF
    This paper analyzes the capability of an optical coherence tomography (OCT) setup to visualize paper structure by comparing experimental and Monte Carlo (MC) simulated OCT images. In the experiments, we used an OCT setup at 910 nm with the coherence length of an SLD source of 7.5 mum. Several different refractive index matching agents were applied to paper samples to enhance the visualization of their inner structure. The obtained OCT images show improved contrast in inner structure and enhanced visualization depth. A set of corresponding simulations were then performed using a previously developed MC code. A multilayer paper sheet model with non-planar fiber-air interfaces was developed to characterize the paper samples. MC simulations were carried out to study the effect of the setup parameters on the obtained OCT images. A comparison with the experimental data shows that the developed model provides a satisfactory correspondence between simulated and experimental images
    corecore