249 research outputs found

    The High Resolution Spectrometer at ISOLDE

    Get PDF
    ISOLDE's HRS (High Resolution isotope Separator) was recommissioned in mid 2000, after a period out of service. Since then, the separator has routinely run with a mass resolution of 3000-4500 and during 2001 it delivered 72% of ISOLDE's radioactive output. A concerted effort has been made to understand the ion optics and optimise performance. In this paper we present an overview of the HRS and investigate the factors which limit the attainable mass resolution: ion-source emittance; optical aberrations; beam instrumentation and magnet stability

    Alkali suppression within laser ion-source cavities and time structure of the laser ionized ion-bunches

    Get PDF
    The chemical selectivity of the target and ion-source production system is an asset for Radioactive Ion-Beam (RIB) facilities equipped with mass separators. Ionization via laser induced multiple resonant steps Ionization has such selectivity. However, the selectivity of the ISOLDE Resonant Ionization Laser Ion-Source (RILIS), where ionization takes place within high temperature refractory metal cavities, suffers from unwanted surface ionization of low ionization potential alkalis. In order to reduce this type of isobaric contaminant, surface ionization within the target vessel was used. On-line measurements of the efficiency of this method is reported, suppression factors of alkalis up to an order of magnitude were measured as a function of their ionization potential. The time distribution of the ion bunches produced with the RILIS was measured for a variety of elements and high temperature cavity materials. While all ions are produced within a few nanoseconds, the ion bunch sometimes spreads over more than 100 ms. This demonstrates that ions are confined within high temperature metallic cavities. It is the internal electrical field of these cavities that causes the ions to drifts to the extraction region and defines the dwell time of the ions in the cavity. Beam optics calculations were carried out to simulate the pulse shape of a RILIS ion bunch and are compared to the actual measurements

    Studies of release properties of ISOLDE targets

    Get PDF
    Off-line release rates of Be, Mg, S, Mn and Kr from refractory materials were studied. Mn yields were determined from a ZrO2 target and Kr yields from a SrO and ZrO2 targets. A Monte Carlo code to optimize ISOLDE targets was introduced

    Decay of neutron-rich Mn nuclides and deformation of heavy Fe isotopes

    Get PDF
    The use of chemically selective laser ionization combined with beta-delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms Mn-61 up through 14-ms Mn-69. The measured half-lives are found to be significantly longer near N=40 than the values calculated with a QRPA shell model using ground-state deformations from the FRDM and ETFSI models. Gamma-ray singles and coincidence spectroscopy has been performed for Mn-64 and Mn-66 decays to levels of Fe-64 and Fe-66, revealing a significant drop in the energy of the first 2+ state in these nuclides that suggests an unanticipated increase in collectivity near N=40

    β\beta - decay of the MT_{T}=-1 nucleus 58^{58}Zn studied by selective laser ionization

    Get PDF
    β\beta - decay of 58^{58}Zn has been studied for the first time. A new laser ion-source concept has been used to produce mass-separated sources for β\beta and γ\gamma - spectroscopy. The half-life of 58^{58}Zn was determined to be 86(18) ms. Comparisons are made with previous data from charge-exchange reactions. Our Gamow-Teller strength to the 1+^{+} state at 1051 keV excitation in 58^{58}Cu agrees well with the value extracted from a recent (3^{3}He, t) study. Extensive shell-model calculations are presented

    The evolution of the ISOLDE control system

    Get PDF
    The ISOLDE on-line mass separator facility is operating on a Personal Computer based control system since spring 1992. Front End Computers accessing the hardware are controlled from consoles running Microsoft WindowsTM through a Novell NetWare4TM local area network. The control system is transparently integrated in the CERN wide office network and makes heavy use of the CERN standard office application programs to control and to document the running of the ISOLDE isotope separators. This paper recalls the architecture of the control system, shows its recent developments and gives some examples of its graphical user interface

    Time Structure of Particle Production in the Merit High-Power Target Experiment

    Get PDF
    The MERIT experiment is a proof-of-principle test of a target system for high power proton beam to be used as front-end for a neutrino factory complex or amuon collider. The experiment took data in autumn 2007 with the fast extracted beam from the CERN Proton Synchrotron (PS) to a maximum intensity of about 30 × 1012 protons per pulse. We report results from the portion of the MERIT experiment in which separated beam pulses were delivered to a free mercury jet target with time intervals between pulses varying from 2 to 700 μs. The analysis is based on the responses of particle detectors placed along side and downstream of the target

    公众参与消防安全建设:路径选择与制度供给

    Get PDF
    消防安全是公共安全的重要组成部分,公众参与消防安全建设是消防安全管理工作的内在需求和必然趋势。积极探索公众参与消防安全建设的具体路径,为公民参与消防建设提供制度保障是当前消防管理工作的重要课题。本文力图从消防政策的制定与监督、社会化的消防工作网络、依托社会的消防教育三个方面构建以政府为主导的公民参与消防安全建设的路径,并为这些参与途径设计了以信息公开及法制建设为基础,以增强民间组织参与能力为目标,以经济、文化等各种手段为支持的公众参与消防建设的制度框架
    corecore