1,532 research outputs found

    MW 775 Christian Witness and Other Faiths

    Get PDF
    Richard Plantinga, ed. Christianity and Plurality: Classic and Contemporary Readings. Oxford: Blackwell, 1999. 379 pages. ISBN: 0-631-20915-8 (paperback) Wesley Pluralism Packet David Bosch. A Spirituality of the Road. Eugene, Oregon: Wipf and Stock, 2000 (1979). 92 pages. ISBN: 1-57910-795-8 (paperback) Paul Hiebert. Missiological Implications of Epistemological Shifts. Harrisburg, PA: Trinity Press, International, 1999. 135 pages. ISBN: 1-56338-259-8 (paperback)https://place.asburyseminary.edu/syllabi/2452/thumbnail.jp

    Intracranial dermoid cysts: variations of radiological and clinical features

    Get PDF
    Background: Intracranial dermoid cysts are uncommon, and their clinical features as well as surgical management differ from patient to patient. Dermoids are generally benign lesions, but may cause spontaneous complications such as meningitis and/or hydrocephalus due to rupture and epileptic seizures depending on their location. Little has been reported about characteristic imaging findings with resulting therapeutic considerations, and only a few reports exist about associated hydrocephalus. Imaging modalities have changed and can facilitate differential diagnosis and follow-up if applied correctly. In this paper, we attempt to contribute our clinical experience with the management of dermoid cysts. Patients and methods: The charts of five men and two women with intracranial dermoid cysts were retrospectively reviewed. The patients were treated between September 1993 and September 2006. Selected patients are presented in detail. Results: Tumour location, size and radiographic characteristics varied in each patient. Clinical presentations comprised focal neurological deficits as well as epileptic seizures, persistent headache, mental changes and psycho-organic syndromes. One patient underwent delayed ventriculo-peritoneal shunting after ruptured fatty particles caused obstructive hydrocephalus. Despite dermoid rupture into the subarachnoid space, three patients never developed hydrocephalus. Diffuse vascular supra-tentorial lesions were seen in one patient as a result of aseptic meningitis. Diffusion-weighted imaging (DWI) hyperintensity in dermoids is related to decrease of water proton diffusion and should be used for both the diagnosis and follow-up of this lesion. Conclusion: Although dermoid cysts are known to be benign entities per se, their rupture can cause a wide range of symptoms including aseptic meningitis and/or hydrocephalus. This may be due to intraventricular obstruction and/or paraventricular compression. While rupture does not necessarily bring about hydrocephalus, radical removal of the tumour and close monitoring of ventricular size is required. Although not widely recognised as such, DWI is considered to be a useful imaging modality in the diagnosis and follow-up of dermoid

    Early surgery versus initial conservative treatment in patients with traumatic intracerebral haemorrhage [STITCH(Trauma)] : the first randomized trial

    Get PDF
    Acknowledgements This project was funded by the NIHR Health Technology Assessment programme (project number 07/37/16). The views and opinions expressed therein are those of the authors and do not necessarily reflect those of the HTA programme, NIHR, NHS or the Department of Health.Peer reviewedPublisher PD

    Model-based myocardial T1 mapping with sparsity constraints using single-shot inversion-recovery radial FLASH cardiovascular magnetic resonance.

    No full text
    BACKGROUND: This study develops a model-based myocardial T1 mapping technique with sparsity constraints which employs a single-shot inversion-recovery (IR) radial fast low angle shot (FLASH) cardiovascular magnetic resonance (CMR) acquisition. The method should offer high resolution, accuracy, precision and reproducibility. METHODS: The proposed reconstruction estimates myocardial parameter maps directly from undersampled k-space which is continuously measured by IR radial FLASH with a 4 s breathhold and retrospectively sorted based on a cardiac trigger signal. Joint sparsity constraints are imposed on the parameter maps to further improve T1 precision. Validations involved studies of an experimental phantom and 8 healthy adult subjects. RESULTS: In comparison to an IR spin-echo reference method, phantom experiments with T1 values ranging from 300 to 1500 ms revealed good accuracy and precision at simulated heart rates between 40 and 100 bpm. In vivo T1 maps achieved better precision and qualitatively better preservation of image features for the proposed method than a real-time CMR approach followed by pixelwise fitting. Apart from good inter-observer reproducibility (0.6% of the mean), in vivo results confirmed good intra-subject reproducibility (1.05% of the mean for intra-scan and 1.17, 1.51% of the means for the two inter-scans, respectively) of the proposed method. CONCLUSION: Model-based reconstructions with sparsity constraints allow for single-shot myocardial T1 maps with high spatial resolution, accuracy, precision and reproducibility within a 4 s breathhold. Clinical trials are warranted

    Imaging of arrhythmia: Real-time cardiac magnetic resonance imaging in atrial fibrillation

    Get PDF
    Objectives Quantitative evaluations of function, volume and mass are fundamental in the diagnostic workup of different cardiovascular diseases and can be exactly determined by CMRI in sinus rhythm. This does not hold true in arrhythmia as CMR is hampered by reconstruction artifacts caused by inconsistent data from multiple heartbeats. Real-time (RT) MRI at high temporal resolution might reduce these problems. Methods Consecutive patients with atrial fibrillation were prospectively included and underwent RT and conventional CINE CMR in randomized order. 29 patients were studied at 1.5 T and 30 patients at 3 T. At 3 T a group of 20 subjects in sinus rhythm served as controls. RT and CINE image quality was evaluated in different planes and for different wall sections using a Likert scale (from zero to four). Volumetric analysis was performed using two types of software and differences between RT and CINE CMR were evaluated. Results In patients with atrial fibrillation RT CMR short axis (SA) resulted in a significantly higher image quality compared to CINE imaging both at 1.5 T and 3 T (1.5 T: mid SA: 3.55 ± 0.5 RT vs 2.6 ± 0.9 CINE, p = 0.0001; 3 T: mid SA: 3.15 ± 0.9 RT vs 2.6 ±1.0 CINE, p = 0.03); This qualitative difference was more marked and significant for the long axis views (2CV and 4CV) at 1.5 T (1.5 T: 2CV: 3.2 ± 0.6 RT vs 2.65 ± 1.1 CINE; p = 0.011; 4CV: 2.9 ± 0.69 RT vs 2.4 ± 0.9 CINE; p = 0.0044). During sinus rhythm CINE images were superior concerning diagnostic quality (3 T mid SA: 3.35 ± 0.45 RT vs 3.8 ± 0.5 CINE, p = 0.008). Quantitative analysis was successful with both software packages and the results showed a good correlation (Pearson correlation between 0.679 and 0.921 for patients). RT CMR resulted in slightly lower functional volumes than CINE CMR (3 T: patients: EDVI 86 ± 29 ml/m2 RT vs 93 29 ml/m2± 29 CINE, Pearson r = 0.902) but similar ejection fractions (3 T: patients: EF 47 ± 16% RT vs 45 ± 13% CINE, Pearson r = 0679; controls: EF 63 ± 6 RT vs 63 ± 3 CINE, Pearson r = 0.695). Conclusion RT CMR improves image quality in arrhythmic patients and renders studies more comfortable. Volumetric analysis is feasible with slightly lower values relative to CINE CMR, while ejection fractions are comparable

    Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-defibrillator

    Get PDF
    AbstractObjectivesThis study evaluated the safety and efficacy of atrial pacing therapies for the treatment and prevention of atrial tachycardia (AT) or atrial fibrillation (AF) in a new dual chamber implantable cardioverter defibrillator (ICD).BackgroundPatients with an ICD may also experience AT or AF that is amenable to pace termination.MethodsThe efficacy of atrial antitachycardia pacing (ATP) therapies for atrial tachycardia or atrial fibrillation (AT/AF) was determined in 151 patients after implantation of a GEM III AT ICD (Medtronic Inc., Minneapolis, Minnesota). The percentage of episodes successfully terminated was adjusted for multiple episodes per patient.ResultsA total of 717 of 728 (96%) episodes classified as AT or AF were judged to be appropriate detections. By device classification, atrial ATP terminated 187 of 383 (40% adjusted) episodes classified as AT compared with 65 of 240 episodes classified as AF (26% adjusted, p = 0.013). Atrial Ramp or Burst+ ATP terminated 184 of 378 episodes of AT (39% adjusted), whereas 50-Hz Burst pacing therapy terminated only 12 of 109 episodes of AT (12% adjusted) and 65 of 240 episodes of AF (26% adjusted). If efficacy was defined as termination of AT/AF within 20 s of delivery of the pacing therapy, ATP therapies terminated 139 of 383 (32% adjusted) episodes of AT compared with 34 of 240 episodes of AF (15% adjusted, p = 0.003). Efficacy was dependent on AT cycle length. Frequent transitions between AT and AF predicted inefficacy of atrial ATP (p < 0.001). Ventricular proarrhythmia secondary to atrial ATP was not observed.ConclusionsAtrial ATP therapies terminate many episodes of AT without ventricular proarrhythmia. The addition of 50-Hz Burst pacing has minimal efficacy for AT/AF
    corecore