97 research outputs found

    Effects of laser ablated silver nanoparticles on Lemna minor

    Get PDF
    Cataloged from PDF version of article.The present study investigates and models the effect of laser ablated silver nanoparticles (AgNPs) on the development of the aquatic macrophyte Lemna minor. Toxic effects of five different AgNP concentrations (8, 16, 32, 96 and 128μgL-1) on L. minor were recorded over seven days under simulated natural conditions. Biosorption of AgNPs by L. minor was modeled using four sorption isotherms, and the sorption behavior was found to agree most closely with the Langmuir-Freundlich model (R2=0.997). While toxic effects of AgNPs could be observed in all models and concentrations, the greatest increase in toxicity was in the 8-32μgL-1 range. Dry weight- and frond number-based inhibition experiments suggest that growth inhibition does not necessarily scale with AgNP concentration, and that slight fluctuations in inhibition rates exist over certain concentration ranges. Very close fits (R2=0.999) were obtained for all removal models, suggesting that the fluctuations are not caused by experimental variation. In addition, L. minor was found to be a successful bioremediation agent for AgNPs, and displayed higher removal rates for increasing AgNP doses. FT-IR spectroscopy suggests that carbonyl groups are involved in AgNP remediation. © 2014 Elsevier Ltd

    Chromium(VI) Biosorption and Bioaccumulation by Live and Acid-Modified Biomass of a Novel Morganella morganii Isolate

    Get PDF
    Conventional methods of chromium removal are often insufficient for the remediation of chromium-contaminated natural environments, necessitating the development of alternative strategies. In this paper, we report the isolation of a novel Morganella morganii strain capable of reducing hexavalent chromium to its less-toxic and less-soluble trivalent form. Cr(VI) reduction by this strain was evaluated in both acidic environments and conditions reflecting natural freshwater sources. The isolate achieved equilibrium within 3 h and displayed a specific uptake rate of 24.30 ± 1.67 mg Cr(VI)/g biomass following HCl treatment. Without acid treatment, a reduction of over 90% was recorded within 72 h for an initial Cr(VI) concentration 20 mg/L, corresponding to a Cr(VI) removal capacity of 19.36 ± 1.89 mg/g. Absorption data of acid-treated STB5 biomass most closely followed the Toth and Langmuir models. FTIR results indicate that hydroxyl groups and extracellular or cell membrane polysaccharides may be potential adsorption sites for hexavalent chromium. Our results suggest that the isolate may be used in situ for treatment of polluted freshwater environments. Copyright © Taylor & Francis Group, LLC

    Vascular Endothelial Dysfunction in β-Thalassemia Occurs Despite Increased eNOS Expression and Preserved Vascular Smooth Muscle Cell Reactivity to NO

    Get PDF
    The hereditary β-thalassemia major condition requires regular lifelong blood transfusions. Transfusion-related iron overloading has been associated with the onset of cardiovascular complications, including cardiac dysfunction and vascular anomalies. By using an untransfused murine model of β-thalassemia major, we tested the hypothesis that vascular endothelial dysfunction, alterations of arterial structure and of its mechanical properties would occur despite the absence of treatments.Vascular function and structure were evaluated ex vivo. Compared to the controls, endothelium-dependent vasodilation with acetylcholine was blunted in mesenteric resistance arteries of β-thalassemic mice while the endothelium-independent vasodilator (sodium nitroprusside) produced comparable vessel dilation, indicating endothelial cell impairment with preserved smooth muscle cell reactivity to nitric oxide (NO). While these findings suggest a decrease in NO bioavailability, Western blotting showed heightened expression of aortic endothelial NO synthase (eNOS) in β-thalassemia. Vascular remodeling of the common carotid arteries revealed increased medial elastin content. Under isobaric conditions, the carotid arteries of β-thalassemic mice exhibited decreased wall stress and softening due to structural changes of the vessel wall.A complex vasculopathy was identified in untransfused β-thalassemic mice characterized by altered carotid artery structure and endothelial dysfunction of resistance arterioles, likely attributable to reduced NO bioavailability despite enhanced vascular eNOS expression

    Circulating CD133+VEGFR2+ and CD34+VEGFR2+ cells and arterial function in patients with beta-thalassaemia major

    Get PDF
    Arterial dysfunction has been documented in patients with beta-thalassaemia major. This study aimed to determine the quantity and proliferative capacity of circulating CD133+VEGFR2+ and CD34+VEGFR2+ cells in patients with beta-thalassaemia major and those after haematopoietic stem cell transplantation (HSCT), and their relationships with arterial function. Brachial arterial flow-mediated dilation (FMD), carotid arterial stiffness, the quantity of these circulating cells and their number of colony-forming units (CFUs) were determined in 17 transfusion-dependent thalassaemia patients, 14 patients after HSCT and 11 controls. Compared with controls, both patient groups had significantly lower FMD and greater arterial stiffness. Despite having increased CD133+VEGFR2+ and CD34+VEGFR2+ cells, transfusion-dependent patients had significantly reduced CFUs compared with controls (p = 0.002). There was a trend of increasing CFUs across the three groups with decreasing iron load (p = 0.011). The CFUs correlated with brachial FMD (p = 0.029) and arterial stiffness (p = 0.02), but not with serum ferritin level. Multiple linear regression showed that CFU was a significant determinant of FMD (p = 0.043) and arterial stiffness (p = 0.02) after adjustment of age, sex, body mass index, blood pressure and serum ferritin level. In conclusion, arterial dysfunction found in patients with beta-thalassaemia major before and after HSCT may be related to impaired proliferation of CD133+VEGFR2+ and CD34+VEGFR2+ cells

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    Unusual cranial magnetic resonance imaging findings in a case with Sydenham's chorea

    No full text
    PubMed ID: 15660881[No abstract available

    Evaluation of aortic stiffness in tobacco-smoking adolescents

    No full text
    WOS: 000220415600012PubMed ID: 15041004Purpose: To measure the aortic stiffness in tobacco-smoking adolescents and to investigate its relationship to tobacco smoke. Methods: Aortic strain (S), pressure strain elastic modulus (E-p), and normalized E-p (E-p*) in tobacco-smoking adolescents and the healthy control group were measured by a sphygmomanometer with cuff and transthoracic echocardiography. The study group consisted of 30 healthy cases (M/F: 27/3) as a control group and 30 tobacco-smoking volunteer adolescents (M/F: 28/2). Unpaired Student's t-test was used for comparison of these groups. Results: The mean ages were 16.1 +/- 1.8 years and 16.2 +/- 1.4 years, respectively. The number of cigarettes smoked per day was 31 +/- 7.1 and the duration of smoking was 3.4 +/- 1.1 years. S, E-p and E-p* measurements of tobacco smokers were different than the control groups' and this difference was statistically significant. S values were significantly higher in nonsmokers than in smokers; whereas E-p and E-p* values were significantly higher in smoker group. Conclusions: This study demonstrated that measurement of aortic stiffness with S, E-p, and E-p,* can be used as an early indicator of atherosclerosis in tobacco-smoking adolescents. (C) Society for Adolescent Medicine, 200

    ventricle in a child

    No full text
    Gurses D, Ozyurek AR, Levent E, Ulger Z. Percutaneous retrieval of a chronic catheter fragment from the left ventricle in a child. Turk J Pediatr 2012; 54: 290-293.Embolization of a catheter fragment is a very rarely seen complication, and few cases have been reported in children. Catheter fragments must be urgently extracted due to life-threatening complications. Most catheter fragments are removed very soon after being lost in the cardiovascular system, including the venous system and right side of the heart. In our report, we describe a child with catheter fragment, which was removed from the left ventricle 32 days after embolization. This catheter fragment was successfully retrieved percutaneously using a gooseneck snare catheter through the femoral artery
    corecore