31 research outputs found

    Inter -and intraobserver variation of ultrasonographic cartilage thickness assessments in small and large joints in healthy children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is an increasing interest among pediatric rheumatologist for using ultrasonography (US) in the daily clinical examination of children with juvenile idiopathic arthritis (JIA). Loss of joint cartilage may be an early feature of destructive disease in JIA. However, US still needs validation before it can be used as a diagnostic bedside tool in a pediatric setting. This study aims to assess the inter- and intraobserver reliability of US measurements of cartilage thickness in the joints of healthy children.</p> <p>Methods</p> <p>740 joints of 74 healthy Caucasian children (27 girls/47 boys), aged 11.3 (7.11 – 16) years were examined with bilateral US in 5 preselected joints to assess the interobserver variability. In 17 of these children (6 girls/11 boys), aged 10.1(7.11–11.1) years, 170 joints was examined in an intraobserver sub study, with a 2 week interval between the first and second examination.</p> <p>Results</p> <p>In this study we found a good inter- and intraobserver agreement expressed as a coefficient of variation (CV) less than 10% in the knee (CV = 9.5%<sub>interobserver </sub>and 5.9%<sub>intraobservserI</sub>, 9.3%<sub>intraobserverII </sub>respectively for the two intraobserver measurements) and fairly good for the MCP joints (CV = 11.9%<sub>interobserver</sub>, 12.9%<sub>intraobserverI </sub>and 11.9%<sub>intraobsevrerII</sub>). In the ankle and PIP joints the inter- and intraobserver agreement was within an acceptable limit (CV<20%) but not for the wrist joint (CV>26%). We found no difference in cartilage thickness between the left and right extremity in the investigated joints.</p> <p>Conclusion</p> <p>We found a good inter -and intraobserver agreement when measuring cartilage thickness with US. The inter- and intraobserver variation seemed not to be related to joint size. These findings suggest that positioning of the joint and the transducer is of major importance for reproducible US measurements. We found no difference in joint cartilage thickness between the left and right extremity in any of the examined joint of the healthy children. This is an important finding giving the opportunity of using the non-affected extremity as a reference when assessing articular joint cartilage damage in JIA.</p

    No evidence of enhanced oxidant production in blood obtained from patients with obstructive sleep apnea

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Obstructive sleep apnea syndrome (OSAS) is a recognized risk factor for cardiovascular morbidity and mortality, perhaps due to causative exacerbations of systemic oxidative stress. Putative oxidative stress related to numerous episodes of intermittent hypoxia, may be an oxidants chief driving force in OSAS patients.</p> <p>Methods</p> <p>We assessed the resting and n-formyl-methionyl-leucyl-phenylalanine (fMLP)- induced whole blood chemiluminescence (as a measure of oxidant production by polymorphonuclear leukocytes and monocytes), ferric reducing ability of plasma (FRAP) and H<sub>2</sub>O<sub>2 </sub>generation in the whole blood of 27 untreated OSAS patients, 22 subjects after a night of CPAP therapy and 11 controls without OSAS. All of them were matched to age, BMI (body mass index) and smoking habits. All parameters were measured before and after polysomnography-controlled sleep, individual results were obtained as a mean from duplicated experiments.</p> <p>Results</p> <p>No significant differences were distinguished between evening and morning blood chemiluminescence, H<sub>2</sub>O<sub>2 </sub>activity and FRAP within and between all three study groups.</p> <p>For instance patients with untreated OSAS had similar morning and evening resting whole blood chemiluminescence (2.3 +/- 2.2 vs. 2.4 +/- 2.2 [aU·10<sup>-4 </sup>phagocytes]), total light emission after stimulation with fMLP (1790 +/- 1371 vs. 1939 +/- 1532 [aU·s·10<sup>-4 </sup>phagocytes]), as well as FRAP after 3 min. plasma incubation (602 +/- 202 vs. 671 +/- 221 [uM]). Although, in the subgroup of 11 patients with severe OSAS (apnea/hypopnea index 58 +/- 18/h and oxygen desaturation index 55 +/- 19/h), the morning vs. evening resting chemiluminescence and total light emission after stimulation with fMLP observed a propensity to elevate 2.5 +/- 2.7 vs. 1.9 +/- 1.8 [aU·10<sup>-4 </sup>phagocytes] and 1778 +/- 1442 vs. 1503 +/- 1391 [aU·s·10<sup>-4 </sup>phagocytes], respectively, these did not attain statistical significance (p > 0.05).</p> <p>Conclusion</p> <p>Our investigation exposed no evidence in the overproduction of oxidants via circulating phagocytes, once considered a culprit in the oxidative stress of OSAS patients.</p

    Assessing the intra- and inter-reader reliability of dynamic ultrasound images in power Doppler ultrasonography

    Get PDF
    OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility
    corecore