744 research outputs found

    Reflections on a Measurement of the Gravitational Constant Using a Beam Balance and 13 Tons of Mercury

    Full text link
    In 2006, a final result of a measurement of the gravitational constant GG performed by researchers at the University of Z\"urich was published. A value of G=6.674\,252(122)\times 10^{-11}\,\mbox{m}^3\,\mbox{kg}^{-1}\,\mbox{s}^{-2} was obtained after an experimental effort that lasted over one decade. Here, we briefly summarize the measurement and discuss the strengths and weaknesses of this approach.Comment: 13 pages, 5 figures accepted for publication in Phil. Trans. R. Soc.

    Seismotectonic study of the Fergana region (Southern Kyrgyzstan): distribution and kinematics of local seismicity

    Get PDF
    We present new seismicity and focal-mechanism data for the Fergana basin and surrounding mountain belts in western Kyrgyzstan from a temporary local seismic network. A total of 210 crustal earthquakes with hypocentral depths shallower than 25 km were observed during a 12-month period in 2009/2010. The hypocenter distribution indicates a complex net of seismically active structures. The seismicity derived in this study is mainly concentrated at the edges of the Fergana basin, whereas the observed rate of seismicity within the basin is low. The seismicity at the dominant tectonic feature of the region, the Talas-Fergana fault, is likewise low, so the fault seems to be inactive or locked. To estimate the uncertainties of earthquake locations derived in this study, a strong explosion with known origin time and location is used as a ground truth calibration event which suggests a horizontal and vertical accuracy of about 1 km for our relocations. We derived 35 focal mechanisms using first motion polarities and retrieved a set of nine moment tensor solutions for earthquakes with moment magnitude (Mw) ranging from 3.3 to 4.9 by waveform inversion. The solutions reveal both thrust and strike-slip mechanisms compatible with a NW-SE direction of compression for the Fergana region. Two previously unknown tectonic structures in the Fergana region could be identified, both featuring strike-slip kinematics. The combined analysis of the results derived in this study allowed a detailed insight into the currently active tectonic structures and their kinematics where little information had previously been available

    The 2008 Nura earthquake sequence at the Pamir-Tian Shan collision zone, southern Kyrgyzstan

    No full text
    We analyzed the 5 October 2008, Mw 6.6 Nura earthquake, which occurred in the border triangle between Kyrgyzstan, Tajikistan, and China, and its aftershock series based on locally recorded seismic data. More than 3000 aftershocks were detected and located, using a double-difference technique and a regional 3-D velocity model. Moment tensors for the main event and the 42 largest aftershocks were determined by full-waveform inversion of long-period displacement seismograms. The Nura main shock was a shallow (∼3.4 km deep) reverse faulting event and occurred on an approximately east striking rupture plane situated east of the Alai Valley, along the Pamir Frontal Thrust of the Trans Alai Range, the leading edge of the Pamir Thrust System. Its presumed rupture plane dips steeply (∼59°) southward. The aftershocks constitute several distinct clusters that can be attributed to the activation of an array of individual faults including the one that was presumably broken by the main shock. Background seismicity occurred mainly further south, behind the crest of the Trans Alai Range, in an approximately east trending zone of dextral transpressional motion in the interior of the Pamir Thrust System. We show that nearly all reactivated structures lie in regions that experienced an increase in Coulomb stress due to the main shock rupture. The Nura earthquake sequence indicates slip partitioning between north-south shortening that creates large earthquakes along the Pamir Frontal Thrust, and lateral movement in the interior of the Pamir Thrust System.This research was funded by DFG bundle TIPAGE (PAK 443), the CAME project bundle TIPTIMON funded by the German Federal Ministry of Education and Research (support code 03G0809), and GFZ. We acknowledge funding for the Earthquake Task Force deployment by GFZ and the Hannover Rück reinsurance company

    Pseudomonas fluorescens CHA0 maintains carbon delivery to Fusarium graminearum-infected roots and prevents reduction in biomass of barley shoots through systemic interactions

    Get PDF
    Soil bacteria such as pseudomonads may reduce pathogen pressure for plants, both by activating plant defence mechanisms and by inhibiting pathogens directly due to the production of antibiotics. These effects are hard to distinguish under field conditions, impairing estimations of their relative contributions to plant health. A split-root system was set up with barley to quantify systemic and local effects of pre-inoculation with Pseudomonas fluorescens on the subsequent infection process by the fungal pathogen Fusarium graminearum. One root half was inoculated with F. graminearum in combination with P. fluorescens strain CHA0 or its isogenic antibiotic-deficient mutant CHA19. Bacteria were inoculated either together with the fungal pathogen or in separate halves of the root system to separate local and systemic effects. The short-term plant response to fungal infection was followed by using the short-lived isotopic tracer 11CO2 to track the delivery of recent photoassimilates to each root half. In the absence of bacteria, fungal infection diverted carbon from the shoot to healthy roots, rather than to infected roots, although the overall partitioning from the shoot to the entire root system was not modified. Both local and systemic pre-inoculation with P. fluorescens CHA0 prevented the diversion of carbon as well as preventing a reduction in plant biomass in response to F. graminearum infection, whereas the non-antibiotic-producing mutant CHA19 lacked this ability. The results suggest that the activation of plant defences is a central feature of biocontrol bacteria which may even surpass the effects of direct pathogen inhibition

    Expression of adhesion molecules and cytokines after coronary artery bypass grafting during normothermic and hypothermic cardiac arrest

    Get PDF
    Objective: Cardiac surgery with cardiopulmonary bypass (CPB) results in vascular injury and tissue damage which involves leukocyte-endothelial interactions mediated by cytokines and adhesion molecules. This study was designed to demonstrate the effect of normothermic and hypothermic CPB to cytokine and soluble adhesion molecule levels in adults and to determine whether these levels correlate to the patients postoperative course. Design and patients: In 25 patients after normothermic and in 25 patients after hypothermic coronary artery bypass grafting with cardiopulmonary bypass (CPB), blood samples for cytokine and soluble adhesion molecule analysis were taken preoperatively, 24, 36, 48 h, and 6 days postoperatively. Soluble adhesion molecules (sE-selectin, sICAM-1) were measured by ELISA and cytokines (TNF-α, IL-6, IL-8) by chemilumenscent-immunoassay. Clinical data were collected prospectively. Results: Postoperatively, adhesion molecule and cytokine levels were significantly elevated after CPB. Mean plasma levels of sICAM-1 was 2.4-fold higher after 6 days. Mean plasma concentration of sE-selectin peaked after 48 h with a 2-fold increase compared to normothermic conditions. In the hypothermia group sICAM-1, sE-selectin, IL-6, and IL-8 showed significantly higher levels (P≪0.0057, P≪0.0012, P≪0.0419, P≪0.0145) after 24 h compared to the normothermia group. No clinical differences were seen. Conclusion: Adhesion molecules and cytokines are elevated after CPB. Patients after hypothermic CPB show significant higher sICAM-1, sE-selectin, IL-6, and IL-8 levels after 24 h compared to normothermic conditions. These results are mainly due to longer CPB and crossclamp times but do not alter the patient's postoperative cours

    A Measurement of Newton's Gravitational Constant

    Get PDF
    A precision measurement of the gravitational constant GG has been made using a beam balance. Special attention has been given to determining the calibration, the effect of a possible nonlinearity of the balance and the zero-point variation of the balance. The equipment, the measurements and the analysis are described in detail. The value obtained for G is 6.674252(109)(54) 10^{-11} m3 kg-1 s-2. The relative statistical and systematic uncertainties of this result are 16.3 10^{-6} and 8.1 10^{-6}, respectively.Comment: 26 pages, 20 figures, Accepted for publication by Phys. Rev.

    5D gravity and the discrepant G measurements

    Full text link
    It is shown that 5D Kaluza-Klein theory stabilized by an external bulk scalar field may solve the discrepant laboratory G measurements. This is achieved by an effective coupling between gravitation and the geomagnetic field. Experimental considerations are also addressed.Comment: 13 pages, to be published in: Proceedings of the 18th Course of the School on Cosmology and Gravitation: The gravitational Constant. Generalized gravitational theories and experiments (30 April-10 May 2003, Erice). Ed. by G. T. Gillies, V. N. Melnikov and V. de Sabbata, (Kluwer), 13pp. (in print) (2003

    Realization of the farad from the dc quantum Hall effect with digitally-assisted impedance bridges

    Full text link
    A new traceability chain for the derivation of the farad from dc quantum Hall effect has been implemented at INRIM. Main components of the chain are two new coaxial transformer bridges: a resistance ratio bridge, and a quadrature bridge, both operating at 1541 Hz. The bridges are energized and controlled with a polyphase direct-digital-synthesizer, which permits to achieve both main and auxiliary equilibria in an automated way; the bridges and do not include any variable inductive divider or variable impedance box. The relative uncertainty in the realization of the farad, at the level of 1000 pF, is estimated to be 64E-9. A first verification of the realization is given by a comparison with the maintained national capacitance standard, where an agreement between measurements within their relative combined uncertainty of 420E-9 is obtained.Comment: 15 pages, 11 figures, 3 table
    corecore