204 research outputs found

    Endovascular treatment of spontaneous isolated abdominal aortic dissection

    Get PDF
    Isolated abdominal aortic dissection is a rare clinical disease representing only 1.3% of all dissections. There are a few case series reported in the literature. The causes of this pathology can be spontaneous, iatrogenic, or traumatic. Most patients are asymptomatic and symptoms are usually abdominal or back pain, while claudication and lower limb ischemia are rare. Surgical and endovascular treatment are two valid options with acceptable results. We herein describe nine cases of symptomatic spontaneous isolated abdominal aortic dissection, out of which four successfully were treated with an endovascular approach between July 2003 and July 2013. All patients were men, smokers, symptomatic (either abdominal or back pain or lower limb ischemia), with a history of high blood pressure, with a medical history negative for concomitant aneurysmatic dilatation or previous endovascular intervention. Diagnosis of isolated abdominal aortic dissection were established by contrast-enhanced computed tomography angiography (CTA) of the thoracic and abdominal aorta. All nine patients initially underwent medical treatment. In four symptomatic cases, non-responsive to medical therapy, bare-metal stents or stent grafts were successfully positioned. All patients completed a CTA follow-up of at least 12 months, during which they remained symptom-free. Endovascular management of this condition is associated with a high rate of technical success and a low mortality; therefore, it can be considered the treatment of choice when it is feasible

    Laparoscopic treatment of abdominal unicentric castleman's disease: a case report and literature review.

    Get PDF
    BACKGROUND: Castleman's disease is a rare lymphoproliferative disorder of unknown etiology that most commonly presents as a mediastinal nodal mass. It is exceptionally uncommon for Castleman's disease to present in the mesentery and, only 53 cases have ever been described in the literature. Standard treatment for this lymphoproliferative disorder involving a single node is a complete "en bloc" surgical resection which has proven to be a curative approach in almost all cases without recurrence after 20 years of follow up. All 53 reported cases of mesenteric Castleman's disease, except one, were treated with laparotomy. CASE PRESENTATION: We report on a case of mesenteric Castleman's disease localized in the mesentery which is the second reported case if its kind and was treated by a laparoscopic-assisted procedure. Our female patient had an uneventful postoperative course and was discharged in the 5th post-operative day. No signs of recurrence were present as evidenced by physical examination and total body CT scan 24 months after the operation. We compare our case with the other reported cases in which Castleman's disease presented as an isolated mass in the abdomen. CONCLUSION: Although a rare disease, Unicentric Castleman's disease should always be considered when a solid asymptomatic abdominal mass is occasionally presented. The laparoscopic approach (LA) allows for the achievement of better results than open surgery, including a reduction in postoperative pain and length of hospital stay. In cases of masses of an uncertain nature, LA must be considered the last diagnostic tool and the first treatment one

    Protein extraction from grape tissues by two-dimensional electrophoresis

    Get PDF
    At the onset of proteomic studies protein samples have to be accurately separated by two dimensional electrophoresis (2-DE); subsequently polypeptides are identified. Grape tissues, in particular roots, can be very problematic due to their hardness and to the high content of compounds that interfere in classical protein extraction. We have used a phenol-based extraction method in the presence of a protease inhibitor and Polyvinylpolypyrrolidone (PVPP). In this paper we demonstrate that this extraction method gives satisfactory and reproducible protein separation allowing the identification of some proteins by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).

    A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm

    Get PDF
    We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012

    The Use of Barbed Suture for Intracorporeal Mechanical Anastomosis During a Totally Laparoscopic Right Colectomy: Is It Safe? A Retrospective Nonrandomized Comparative Multicenter Study

    Get PDF
    Background. A totally laparoscopic right colectomy could be perceived as a more challenging procedure over a laparoscopic-assisted right colectomy owing to the difficulty of intracorporeal anastomosis and the closure of the enterotomy. The aim of this study is to evaluate the safety and efficacy of the barbed auto-locking absorbable suture for the closure of an anastomotic stapler-access enterotomy during a totally laparoscopic right colectomy. Methods. From January 2010 to April 2016, data from patients who had undergone a laparoscopic right colectomy in 2 different departments of 2 institutions (the Department of General and Minimally Invasive Surgery, San Camillo Hospital in Trento and the Department of Surgical Specialties and Nephrology, University Federico II in Naples) were retrospectively analyzed. We compared the data of patients in whom the stapler-access enterotomy was closed through a conventional absorbable suture (Group A), with the data of patients in whom a stapler-access enterotomy was closed through a V-Loc 180 suture (Group B). Biometric features and intraoperative and postoperative data were collected and analyzed. Results. The 2 groups (Group A: 40 patients; Group B: 40 patients) were comparable for biometric features and postoperative outcomes. The anastomosing time was lower in Group B. A statistically significant difference was noted in the mean operative time between Groups A and B (Group A = 134.92 ± 34.17; Group B = 120.92 ± 23.27, P =.035). Only one anastomotic leakage per group was recorded, each treated with an anastomosis redo. During the reoperations, we find in both groups an intact stapler-access enterotomy. Conclusion. On retrospective analysis, barbed suture appears to be safe and efficient for closure of the stapler-access enterotomy during totally laparoscopic right colectomy

    User needs elicitation via analytic hierarchy process (AHP). A case study on a Computed Tomography (CT) scanner

    Get PDF
    Background: The rigorous elicitation of user needs is a crucial step for both medical device design and purchasing. However, user needs elicitation is often based on qualitative methods whose findings can be difficult to integrate into medical decision-making. This paper describes the application of AHP to elicit user needs for a new CT scanner for use in a public hospital. Methods: AHP was used to design a hierarchy of 12 needs for a new CT scanner, grouped into 4 homogenous categories, and to prepare a paper questionnaire to investigate the relative priorities of these. The questionnaire was completed by 5 senior clinicians working in a variety of clinical specialisations and departments in the same Italian public hospital. Results: Although safety and performance were considered the most important issues, user needs changed according to clinical scenario. For elective surgery, the five most important needs were: spatial resolution, processing software, radiation dose, patient monitoring, and contrast medium. For emergency, the top five most important needs were: patient monitoring, radiation dose, contrast medium control, speed run, spatial resolution. Conclusions: AHP effectively supported user need elicitation, helping to develop an analytic and intelligible framework of decision-making. User needs varied according to working scenario (elective versus emergency medicine) more than clinical specialization. This method should be considered by practitioners involved in decisions about new medical technology, whether that be during device design or before deciding whether to allocate budgets for new medical devices according to clinical functions or according to hospital department

    Smoke Evacuation During Laparoscopic Surgery: A Problem Beyond the COVID-19 Period. A Quantitative Analysis of CO2 Environmental Dispersion Using Different Devices

    Get PDF
    Background. The COVID-19 pandemic leads to several debates regarding the possible risk for healthcare professionals during surgery. SAGES and EAES raised the issue of the transmission of infection through the surgical smoke during laparoscopy. They recommended the use of smoke evacuation devices (SEDs) with CO2 filtering systems. The aim of the present study is to compare the efficacy of different SEDs evaluating the CO2 environmental dispersion in the operating theater. Methods. We prospectively evaluated the data of 4 group of patients on which we used different SEDs or standard trocars: AIRSEAL system (S1 group), a homemade device (S2 group), an AIRSEAL system + homemade device (S3 group), and with standard trocars and without SED (S4 group). Quantitative analysis of CO2 environmental dispersion was carried out associated to the following data in order to evaluate the pneumoperitoneum variations: a preset insufflation pressure, real intraoperative pneumoperitoneum pressure, operative time, total volume of insufflated CO2, and flow rate index. Results. 16 patients were prospectively enrolled. The [CO2] mean value was 711 ppm, 641 ppm, 593 ppm, and 761 ppm in S1, S2, S3, and S4 groups, respectively. The comparison between data of all groups showed statistically significant differences in the measured ambient CO2 concentration. Conclusion. All tested SEDs seem to be useful to reduce the CO2 environmental dispersion respect to the use of standard trocars. The association of AIRSEAL system and a homemade device seems to be the best solution combining an adequate smoke evacuation and a stable pneumoperitoneum during laparoscopic surgery

    Stent-assisted detachable coil embolization of wide-necked renal artery aneurysms

    Get PDF
    Renal artery aneurysms (RAAs) are rare with an estimated incidence of 0.1% in the general population, and they represent approximately 25% of all visceral aneurysms. The gold standard of treatment is open surgery, but it is associated with a high risk of nephrectomy, mortality, and morbidity. Less invasive endovascular therapies are becoming increasingly common for the treatment of RAAs. Here, we aimed to report three cases of wide-necked complex renal artery aneurysms treated endovascularly using stent-assisted coil embolization with self-expandable stent nitinol Solitaire AB and Concerto Axium coils. In addition, we describe the use of the waffle-cone technique in a case of wide-necked saccular RAA involving the renal artery bifurcation. Technical success was achieved in all three cases with no early or late complications and no recurrences

    Assessment of blood perfusion quality in laparoscopic colorectal surgery by means of Machine Learning

    Get PDF
    An innovative algorithm to automatically assess blood perfusion quality of the intestinal sector in laparoscopic colorectal surgery is proposed. Traditionally, the uniformity of the brightness in indocyanine green-based fluorescence consists only in a qualitative, empirical evaluation, which heavily relies on the surgeon’s subjective assessment. As such, this leads to assessments that are strongly experience-dependent. To overcome this limitation, the proposed algorithm assesses the level and uniformity of indocyanine green used during laparoscopic surgery. The algorithm adopts a Feed Forward Neural Network receiving as input a feature vector based on the histogram of the green band of the input image. It is used to (i) acquire information related to perfusion during laparoscopic colorectal surgery, and (ii) support the surgeon in assessing objectively the outcome of the procedure. In particular, the algorithm provides an output that classifies the perfusion as adequate or inadequate. The algorithm was validated on videos captured during surgical procedures carried out at the University Hospital Federico II in Naples, Italy. The obtained results show a classification accuracy equal to 99.9 % , with a repeatability of 1.9 %. Finally, the real-time operation of the proposed algorithm was tested by analyzing the video streaming captured directly from an endoscope available in the OR
    • …
    corecore