    Some Flight Characteristics of a Deflected Slipstream V/STOL Aircraft

    Get PDF
    The Ryan VZ-3RY V/STOL test vehicle was flight tested over the airspeed range from 80 knots to below 6 knots. The deflected slipstream concept proved to be better suited to STOL than VTOL operation. Adverse ground effects prevented operation close to the ground at speeds less than 20 knots and below approximately 15 feet altitude. Steep glide slopes to landing (up to -16 deg) at approximately 40 knots were achieved, but steep, slow, descending flight did not appear feasible. Full-span leading-edge slats markedly increased the descent capability and reduced the minimum level flight speed

    Polyetheretherketone as a Biomaterial for Spinal Applications

    Get PDF
    Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. Only mild chronic inflammation consisting of a few macrophages was observed in peri-implant tissues. Based on these results, the polymeric biomaterial PEEK may be a useful biomaterial for interbody fusion cages due to the polymer\u27s increased radiolucency and decreased stiffness

    Pressure Lag in Tubing Used in Flight Research

    Get PDF
    Tests described in this report were undertaken to obtain a quantitative measure of the pressure lag in typical pressure-tubing systems used by the Ames Aeronautical Laboratory in flight research investigations. Lag measurements were made with both single-direction and oscillating pressure changes. Single-direction pressure changes were investigated to determine if the lag in orifice-pressure lines and in the research airspeed and altitude measuring systems of pursuit-type airplane undergoing flight tests was sufficient to cause an appreciable error in the record of a sudden pressure change. Oscillating pressure changes were investigated with particular reference to the accuracy of pressure peaks in pressure-distribution measurements during the time of buffeting conditions as found in stalls. (author

    Bioresorbable Polylactide Interbody Implants in an Ovine Anterior Cervical Discectomy and Fusion Model: Three-Year Results

    Get PDF
    Study Design. In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model. Objective. To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process. Summary of Background Data. The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. Although preclinical and clinical studies have demonstrated the suitability of polylactide implants for lumbar interbody fusion, detailed information on cervical anterior cervical discectomy and fusion (ACDF) with polylactide devices is desirable. Methods. Single level ACDF was performed in 8 skeletally mature ewes. Bioresorbable 70:30 poly (l-lactide-co-d,l-lactide) interbody implants packed with autograft were used with single-level metallic plates. Radiographs were made every 3 months up to 1 year, and yearly thereafter. The animals were killed at 6 months (3 animals), 12 months (3 animals), and 36 months (2 animals). In addition to the serial plain radiographs, the specimens were evaluated by nondestructive biomechanical testing and undecalcified histologic analysis. Results. The bioresorbable polylactide implants were effective in achieving interbody fusion. The 6-month animals appeared fused radiographically and biomechanically, whereas histologic sections demonstrated partial fusion (in 3 of 3 animals). Radiographic fusion was confirmed histologically and biomechanically at 12 months (3 of 3 animals) and 36 months (2 of 2 animals). A mild chronic inflammatory response to the resorbing polylactide implant was observed at both 6 months and 12 months. At 36 months, the operative levels were solidly fused and the implants were completely resorbed. No adverse tissue response was observed in any animal at any time period. Conclusion. Interbody fusion was achieved using bioresorbable polylactide implants, with no evidence of implant collapse, extrusion, or adverse tissue response to the material. The use of polylactide as a cervical interbody device appears both safe and effective based on these ACDF animal model results
    • …