42 research outputs found

    Whole-body magnetic resonance imaging (WBMRI) versus whole-body computed tomography (WBCT) for myeloma imaging and staging

    Get PDF
    Myeloma-associated bone disease (MBD) develops in about 80-90% of patients and severely affects their quality of life, as it accounts for the majority of mortality and morbidity. Imaging in multiple myeloma (MM) and MBD is of utmost importance in order to detect bone and bone marrow lesions as well as extraosseous soft-tissue masses and complications before the initiation of treatment. It is required for determination of the stage of disease and aids in the assessment of treatment response. Whole-body low-dose computed tomography (WBLDCT) is the key modality to establish the initial diagnosis of MM and is now recommended as reference standard procedure for the detection of lytic destruction in MBD. In contrast, whole-body magnetic resonance imaging (WBMRI) has higher sensitivity for the detection of focal and diffuse plasma cell infiltration patterns of the bone marrow and identifies them prior to osteolytic destruction. It is recommended for the evaluation of spinal and vertebral lesions, while functional, diffusion-weighted MRI (DWI-MRI) is a promising tool for the assessment of treatment response. This review addresses the current improvements and limitations of WBCT and WBMRI for diagnosis and staging in MM, underlining the fact that both modalities offer complementary information. It further summarizes the corresponding radiological findings and novel technological aspects of both modalities

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    A pitfall of bilateral inferior petrosal sinus sampling in cyclic Cushing's syndrome

    Get PDF
    Background: Clinical care of patients with cyclic Cushing's syndrome (CS) is challenging. Classical pitfalls include incorrect subtyping, unnecessary surgical procedures and delayed definite treatment. Case presentation: A 43-year-old female suffered from a rapidly cycling ectopic CS. She experienced six cycles of severe hypercortisolism within a 2 year period (maximum plasma cortisol 5316 nmol/L, normal range 124.2-662.4 nmol/L; maximum urinary free cortisol 79,469 nmol/24 h, normal range < 414 nmol/24 h) lasting 2-9 weeks. The episodes were associated with pronounced hypokalemia (lowest K+ value recorded 2.4 mmol/l) and progressive signs and symptoms of CS. A bilateral inferior petrosal sinus sampling (BIPSS) performed during a trough phase was false positive for pituitary ACTH overproduction resulting in unnecessary transsphenoidal surgery while a second BIPSS performed during an active phase was indicative for ectopic CS. The 18F-DOPA PET/CT showed a pancreatic lesion, which was subsequently partially removed. Surprisingly, the histopathology was conclusive for ACTH-positive lymph node metastasis located in the retro-duodenal tissue of an occult neuroendocrine tumor WHO grade II. The primary tumor has not been identified so far and, because of the persistent hypercortisolism, the patient underwent bilateral adrenalectomy. Two years later, ACTH levels started to increase progressively. Percutaneous biopsy of a newly identified suspected lesion in the fifth thoracic vertebra revealed a metastasis with positive staining for ACTH, synaptophysin and chromogranin A. Therapy with carboplatin and etoposide was started and, since then, the patient underwent 12 cycles of chemotherapy. Conclusions: We report the challenging case of a rapidly cycling CS secondary to ACTH-secreting neuroendocrine intestinal tumor of unknown primary. We highlight the importance of performing diagnostic tests only during the phases of active cortisol secretion and as soon as first symptoms appear to avoid pitfalls

    Three-Dimensional High-Resolution Black-Blood Magnetic Resonance Imaging for Detection of Arteritic Anterior Ischemic Optic Neuropathy in Patients With Giant Cell Arteritis

    Get PDF
    Objectives: Arteritic anterior ischemic optic neuropathy (A-AION) caused by inflammatory occlusion of the posterior ciliary arteries is the most common reason for irreversible vision loss in patients with giant cell arteritis. Atypical clinical presentation and negative funduscopy can delay systemic high-dose corticosteroid therapy to prevent impending permanent blindness and involvement of the contralateral eye. The purpose of this study was to assess the diagnostic accuracy of 3-dimensional (3D) high-resolution T1-weighted black-blood magnetic resonance imaging (T1-BB-MRI) for the detection of posterior ciliary artery involvement in patients with giant cell arteritis and funduscopic A-AION. Materials and Methods: After institutional review board approval and informed consent, 27 patients with suspected giant cell arteritis and vision disturbances were included in this monocentric prospective cohort study. Giant cell arteritis was diagnosed in 18 patients according to the diagnostic reference standard (6 men, 73.8 [69.0-78.0] years);14 of those were positive for A-AION. Precontrast and postcontrast 3D T1-BB-MRI was performed in all 27 patients. Two radiologists separately assessed image quality and local fat suppression (4-point scale), visual contrast enhancement (3-point scale), and diagnostic confidence (5-point scale) regarding arteritic posterior ciliary artery involvement. Magnetic resonance imaging findings were assessed in comparison to funduscopy. Statistical analysis included accuracy parameters and interrater agreement. Results: Sensitivity of 3D T1-BB-MRI was 92.9% (95% confidence interval, 66.1%-99.8%) and specificity was 92.3% (95% confidence interval, 64.0%-99.8%) for detection of A-AION-positive patients. Image quality and local fat suppression were assessed with 3.2 +/- 0.8 (median 3) and 3.8 +/- 0.5 (median 4). Visual contrast enhancement with 2.3 +/- 0.8 (median 3) and diagnostic confidence was rated at 4.7 +/- 0.5 (median 5). Interrater agreement was high (kappa = 0.85, P < 0.001). Three-dimensional T1-BB-MRI displayed bilateral findings in 50% of the cases, whereas only unilateral A-AION was detected in funduscopy as a possible indication for the contralateral eye at risk. Conclusions: Three-dimensional T1-BB-MRI allows accurate detection of arteritic posterior ciliary artery involvement in patients with A-AION. Further, 3D T1-BB-MRI seems to display arteritic involvement of the posterior ciliary arteries earlier than funduscopy and might, therefore, display "vision-at-risk" in patients with visual impairment and suspected giant cell arteritis but unremarkable funduscopy

    Radiation exposure of adrenal vein sampling: a German Multicenter Study

    Get PDF
    Objective: Adrenal vein sampling (AVS) represents the current diagnostic standard for subtype differentiation in primary aldosteronism (PA). However, AVS has its drawbacks. It is invasive, expensive, requires an experienced interventional radiologist and comes with radiation exposure. However, exact radiation exposure of patients undergoing AVS has never been examined. Design and methods: We retrospectively analyzed radiation exposure of 656 AVS performed between 1999 and 2017 at four university hospitals. The primary outcomes were dose area product (DAP) and fluoroscopy time (FT). Consecutively the effective dose (ED) was approximately calculated. Results: Median DAP was found to be 32.5Gy*cm(2) (0.3-3181) and FT 18 min (0.3-184). The calculated ED was 6.4 mSv (0.1-636). Remarkably, values between participating centers highly varied: Median DAP ranged from 16 to 147 Gy*cm(2), FT from 16 to 27 min, and ED from 3.2 to 29 mSv. As main reason for this variation, differences regarding AVS protocols between centers could be identified, such as number of sampling locations, frames per second and the use of digital subtraction angiographies. Conclusion: This first systematic assessment of radiation exposure in AVS not only shows fairly high values for patients, but also states notable differences among the centers. Thus, we not only recommend taking into account the risk of radiation exposure, when referring patients to undergo AVS, but also to establish improved standard operating procedures to prevent unnecessary radiation exposure

    Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging

    Get PDF
    Objectives: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS).& para;& para;Materials and Methods: After institutional review board approval and informed consent, 22 patients (8 men;aged 31.0 +/- 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study.& para;& para;Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm(3) resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm(3) resolution (T1-mVISTA_1.0). Reference lesions were 2-defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests.& para;& para;Results: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE (P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively;P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detect-ability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes.& para;& para;Conclusions: Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management
    corecore