180 research outputs found
Assessing the effect of beard hair lengths on face masks used as personal protective equipment during the COVID-19 pandemic
Background Globally, a large percentage of men keep a beard at least occasionally. Workplace regulations prohibit beards with N95 respirators, but there is little information on the effect of beards with face masks worn by the public for protection against SARS-CoV-2. Methods and findings We examined the fitted filtration efficiency (FFE) of five commonly worn protective face masks as a function of beard length following the US Occupational Safety and Health Administration Quantitative Fit Test: N95 (respirator), KF94 and KN95, surgical/procedure, and cloth masks. A comparison using N95 respirators was carried out in shaven and bearded men. A detailed examination was conducted for beard lengths between 0 and 10 mm (0.5 mm increments). The effect of an exercise band covering the beard on FFE was also tested. Although N95 respirators showed considerable variability among bearded men, they had the highest FFE for beard lengths up to 10 mm. KF94 and KN95 masks lost up to 40% of their FFE. Procedure and cotton masks had poor performance even on bare skin (10–30% FFE) that did not change appreciably with beard length. Marked performance improvements were observed with an exercise band worn over the beard. Conclusions Though variable, N95 respirators offer the best respiratory protection for bearded men. While KF94 and KN95 FFE is compromised considerably by increasing beard length, they proved better options than procedure and cotton face masks. A simple exercise band improves FFE for face masks commonly used by bearded men during the COVID-19 pandemic
Filtration Efficiency of Hospital Face Mask Alternatives Available for Use during the COVID-19 Pandemic
Importance: Procuring respiratory protection for clinicians and other health care workers has become a major challenge of the coronavirus disease 2019 (COVID-19) pandemic and has resulted in nonstandard practices such as the use of expired respirators and various decontamination processes to prolong the useful life of respirators in health care settings. In addition, imported, non-National Institute for Occupational Safety and Health (NIOSH)-approved respirators have been donated or acquired by hospitals as a potential replacement for limited NIOSH-approved N95 respirators. Objective: To assess fitted filtration efficiencies (FFEs) for face mask alternatives used during the COVID-19 pandemic. Design, Setting, and Participants: For this quality-improvement study conducted between April and June 2020, we used the Occupational Safety and Health Administration's Quantitative Fit Testing Protocol for Filtering Facepiece Respirators in a laboratory atmosphere supplemented with sodium chloride particles to assess the FFEs of a variety of respirators worn by a male volunteer and female volunteer. Main Outcomes and Measures: The FFEs of respirators commonly worn by clinicians and other health care workers and available respirator alternatives during the COVID-19 pandemic. Results: Of the 29 different fitted face mask alternatives tested on 1 man and 1 woman, expired N95 respirators with intact elastic straps and respirators subjected to ethylene oxide and hydrogen peroxide sterilization had unchanged FFE (>95%). The performance of N95 respirators in the wrong size had slightly decreased performance (90%-95% FFE). All of the respirators not listed as approved in this evaluation (n = 6) failed to achieve 95% FFE. Neither of the 2 imported respirators authorized for use by the Centers for Disease Control and Prevention that were not NIOSH-approved tested in this study achieved 95% FFE, and the more effective of the 2 functioned at approximately 80% FFE. Surgical and procedural face masks had filtering performance that was lower relative to that of N95 respirators (98.5% overall FFE), with procedural face masks secured with elastic ear loops showing the lowest efficiency (38.1% overall FFE). Conclusions and Relevance: This quality-improvement study evaluating 29 face mask alternatives for use by clinicians interacting with patients during the COVID-19 pandemic found that expired N95 respirators and sterilized, used N95 respirators can be used when new N95 respirators are not available. Other alternatives may provide less effective filtration
New early Eocene tapiromorph perissodactyls from the Ghazij Formation of Pakistan, with implications for mammalian biochronology in Asia
Early Eocene mammals from Indo-Pakistan have only recently come under study. Here we describe the first tapiromorph perissodactyls from the subcontinent. Gandheralophus minor n. gen. and n. sp. and G. robustus n. sp. are two species of Isectolophidae differing in size and in reduction of the anterior dentition. Gandheralophus is probably derived from a primitive isectolophid such as Orientolophus hengdongensis from the earliest Eocene of China, and may be part of a South Asian lineage that also contains Karagalax from the middle Eocene of Pakistan. Two specimens are referred to a new, unnamed species of Lophialetidae. Finally, a highly diagnostic M3 and a molar fragment are described as the new eomoropid chalicothere Litolophus ghazijensis sp. nov. The perissodactyls described here, in contrast to most other mammalian groups published from the early Eocene of Indo-Pakistan, are most closely related to forms known from East and Central Asia. Tapiromorpha are diverse and biochronologically important in the Eocene there and our results allow the first biochronological correlation between early Eocene mammal faunas in Indo-Pakistan and the rest of Asia. We suggest that the upper Ghazij Formation of Pakistan is best correlated with the middle or late part of the Bumbanian Asian Land-Mammal Age, while the Kuldana and Subathu Formations of Pakistan and India are best correlated with the Arshantan Asian Land-Mammal Age
Contractile Dysfunction Irrespective of the Mutant Protein in Human Hypertrophic Cardiomyopathy With Normal Systolic Function
Background-Hypertrophic cardiomyopathy (HCM), typically characterized by asymmetrical left ventricular hypertrophy, frequently is caused by mutations in sarcomeric proteins. We studied if changes in sarcomeric properties in HCM depend on the underlying protein mutation. Methods and Results-Comparisons were made between cardiac samples from patients carrying a MYBPC3 mutation (MYBPC3(mut); n = 17), mutation negative HCM patients without an identified sarcomere mutation (HCM(mn); n = 11), and nonfailing donors (n = 12). All patients had normal systolic function, but impaired diastolic function. Protein expression of myosin binding protein C (cMyBP-C) was significantly lower in MYBPC3(mut) by 33 +/- 5%, and similar in HCM(mn) compared with donor. cMyBP-C phosphory Conclusions-Changes in sarcomere function reflect the clinical HCM phenotype rather than the specific MYBPC3 mutation. Hypocontractile sarcomeres are a common deficit in human HCM with normal systolic left ventricular function and may contribute to HCM disease progression. (Circ Heart Fail. 2012; 5: 36-46.
Domain Wall Junction in N=2 Supersymmetric QED in four dimensions
An exact solution of domain wall junction is obtained in N=2 supersymmetric
(SUSY) QED with three massive hypermultiplets. The junction preserves two out
of eight SUSY. Both a (magnetic) Fayet-Iliopoulos (FI) term and complex masses
for hypermultiplets are needed to obtain the junction solution. There are zero
modes corresponding to spontaneously broken translation, SUSY, and U(1). All
broken and unbroken SUSY charges are explicitly worked out in the Wess-Zumino
gauge in N=1 superfields as well as in components. The relation to models in
five dimensions is also clarified.Comment: 27 pages, 6 figures, comments on zero modes added, a few references
adde
Measurements of the observed cross sections for exclusive light hadrons containing at , 3.650 and 3.6648 GeV
By analyzing the data sets of 17.3, 6.5 and 1.0 pb taken,
respectively, at , 3.650 and 3.6648 GeV with the BES-II
detector at the BEPC collider, we measure the observed cross sections for
, , ,
and at the three energy
points. Based on these cross sections we set the upper limits on the observed
cross sections and the branching fractions for decay into these
final states at 90% C.L..Comment: 7 pages, 2 figure
Partial wave analysis of J/\psi \to \gamma \phi \phi
Using events collected in the BESII detector, the
radiative decay is
studied. The invariant mass distribution exhibits a near-threshold
enhancement that peaks around 2.24 GeV/.
A partial wave analysis shows that the structure is dominated by a
state () with a mass of
GeV/ and a width of GeV/. The
product branching fraction is: .Comment: 11 pages, 4 figures. corrected proof for journa
Direct Measurements of Absolute Branching Fractions for D0 and D+ Inclusive Semimuonic Decays
By analyzing about 33 data sample collected at and around 3.773
GeV with the BES-II detector at the BEPC collider, we directly measure the
branching fractions for the neutral and charged inclusive semimuonic decays
to be and , and determine the ratio of the two branching
fractions to be
Measurements of the observed cross sections for exclusive light hadron production in e^+e^- annihilation at \sqrt{s}= 3.773 and 3.650 GeV
By analyzing the data sets of 17.3 pb taken at GeV
and 6.5 pb taken at GeV with the BESII detector at the
BEPC collider, we have measured the observed cross sections for 12 exclusive
light hadron final states produced in annihilation at the two energy
points. We have also set the upper limits on the observed cross sections and
the branching fractions for decay to these final states at 90%
C.L.Comment: 8 pages, 5 figur
Search for the Rare Decays J/Psi --> Ds- e+ nu_e, J/Psi --> D- e+ nu_e, and J/Psi --> D0bar e+ e-
We report on a search for the decays J/Psi --> Ds- e+ nu_e + c.c., J/Psi -->
D- e+ nu_e + c.c., and J/Psi --> D0bar e+ e- + c.c. in a sample of 5.8 * 10^7
J/Psi events collected with the BESII detector at the BEPC. No excess of signal
above background is observed, and 90% confidence level upper limits on the
branching fractions are set: B(J/Psi --> Ds- e+ nu_e + c.c.)<4.8*10^-5, B(J/Psi
--> D- e+ nu_e + c.c.) D0bar e+ e- + c.c.)<1.1*10^-5Comment: 10 pages, 4 figure
- …