13 research outputs found

    Comparison of Targeted vs Random Biopsies for Surveillance of Ulcerative Colitis-Associated Colorectal Cancer

    Get PDF
    Background & AimsA random biopsy is recommended for surveillance of ulcerative colitis (UC)-associated colorectal cancer. However, a targeted biopsy might be more effective. We conducted a randomized controlled trial to compare rates of neoplasia detection by targeted vs random biopsies in patients with UC.MethodsWe performed a study of 246 patients with UC for 7 years or more, seen at 52 institutions in Japan from October 1, 2008 through December 31, 2010. Patients were randomly assigned to the random group (4 random biopsies collected every 10 cm in addition to targeted biopsies, n = 122) or the target group (biopsies collected from locations of suspected neoplasia, n = 124). The primary end point was the number of neoplastic lesions detected in a single surveillance colonoscopy. We estimated the ratio and difference in the mean number of neoplastic lesions between the groups. We also evaluated the non-inferiority between the groups as an exploratory study. A non-inferiority margin of 0.65 (0.13 of 0.20) was considered for the ratio of the mean number of neoplastic lesions between groups.ResultsThe mean number of biopsies found to contain neoplastic tissue per colonoscopy was 0.211 (24 of 114) in the target group and 0.168 (18 of 107) in the random group (ratio of 1.251; 95% confidence interval, 0.679–2.306). The lower limit was above the non-inferiority margin of 0.65. Neoplasias were detected in 11.4% of patients in the target group and 9.3% of patients in the random group (P = .617). Larger numbers of biopsy samples per colonoscopy were collected in the random group (34.8 vs 3.1 in the target group; P < .001), and the total examination time was longer (41.7 vs 26.6 minutes in the target group; P < .001). In the random group, all neoplastic tissues found in random biopsies were collected from areas of the mucosa with a history or presence of inflammation.ConclusionsIn a randomized controlled trial, we found that targeted and random biopsies detect similar proportions of neoplasias. However, a targeted biopsy appears to be a more cost-effective method. Random biopsies from areas without any signs of present or past inflammation were not found to contain neoplastic tissues. Clinical Trial Registry: UMIN000001608

    First Data Release of the Hyper Suprime-Cam Subaru Strategic Program

    Full text link
    The Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) is a three-layered imaging survey aimed at addressing some of the most outstanding questions in astronomy today, including the nature of dark matter and dark energy. The survey has been awarded 300 nights of observing time at the Subaru Telescope and it started in March 2014. This paper presents the first public data release of HSC-SSP. This release includes data taken in the first 1.7 years of observations (61.5 nights) and each of the Wide, Deep, and UltraDeep layers covers about 108, 26, and 4 square degrees down to depths of i~26.4, ~26.5, and ~27.0 mag, respectively (5sigma for point sources). All the layers are observed in five broad bands (grizy), and the Deep and UltraDeep layers are observed in narrow bands as well. We achieve an impressive image quality of 0.6 arcsec in the i-band in the Wide layer. We show that we achieve 1-2 per cent PSF photometry (rms) both internally and externally (against Pan-STARRS1), and ~10 mas and 40 mas internal and external astrometric accuracy, respectively. Both the calibrated images and catalogs are made available to the community through dedicated user interfaces and database servers. In addition to the pipeline products, we also provide value-added products such as photometric redshifts and a collection of public spectroscopic redshifts. Detailed descriptions of all the data can be found online. The data release website is https://hsc-release.mtk.nao.ac.jp/.Comment: 34 pages, 20 figures, 7 tables, moderate revision, accepted for publication in PAS

    The Hyper Suprime-Cam SSP survey: Overview and survey design

    Get PDF
    Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey

    Is the total review time of new medical devices related to the size of the company?: Medical devices development and its related factors in Japan

    No full text
    Japan has one of the largest medical device markets in the world, but most devices used in Japan are pioneered by foreign medical device companies. On the other hand, medical device companies in Japan have significant potential to develop innovative medical devices. Through this research, we aim to elucidate the factors related to the total review time of new medical devices so that innovative medical devices would be developed sooner. Using the lists of approved medical devices disclosed by the Pharmaceuticals and Medical Devices Agency (PMDA), we chose all the new medical devices that were approved in Japan between Fiscal Year (FY) 2009 and 2015. We conducted two main types of analyses based on the total review time after submission and sales of the companies. The total review time tends to decrease with "Year of approval by the PMDA'' in FY 2009 to 2015 (p &lt; 0.001). Moreover, the total review time of small and medium-sized companies is greater than that of large companies (p = 0.004). In conclusion, the total review time of new medical devices in Japan appears to be related to the following two factors: (1) year of approval, and (2) size of the enterprise.https://doi.org/10.21423/jrs-v06n02p024 (DOI assigned 1/24/2019

    Synthesis and Characterization of Poly(1,2-dithiane)

    No full text
    corecore