775 research outputs found

    Quadratic Mixing of Radio Frequency Signals using Superconducting Quantum Interference Filters

    Full text link
    The authors demonstrate quadratic mixing of weak time harmonic electromagnetic fields applied to Superconducting Quantum Interference Filters, manufactured from high-TcT_{\mathrm{c}} grain boundary Josephson junctions and operated in active microcooler. The authors use the parabolic shape of the dip in the dc-voltage output around B=0 to mix \emph{quadratically} two external rf-signals, at frequencies f1f_{\mathrm{1}} and f2f_{\mathrm{2}} well below the Josephson frequency fJf_{\mathrm{J}}, and detect the corresponding mixing signal at ∣f1−f2∣| {f_{1}-f_{2}}| . Quadratic mixing takes also place when the SQIF is operated without magnetic shield. The experimental results are well described by a simple analytical model based on the adiabatic approximation.Comment: 3 pages, 3 figure

    High performance magnetic field sensor based on Superconducting Quantum Interference Filters

    Full text link
    We have developed an absolute magnetic field sensor using Superconducting Quantum Interference Filter (SQIF) made of high-T_c grain boundary Josephson junctions. The device shows the typical magnetic field dependent voltage response V(B), which is sharp delta-like dip in the vicinity of zero magnetic field. When the SQIF is cooled with magnetic shield, and then the shield is removed, the presence of the ambient magnetic field induces a shift of the dip position from B_0 ~ 0 to a value B ~ B_1, which is about the average value of the earth magnetic field, at our latitude. When the SQIF is cooled in the ambient field without shielding, the dip is first found at B ~ B_1, and the further shielding of the SQIF results in a shift of the dip towards B_0 ~ 0. The low hysteresis observed in the sequence of experiments (less than 5% of B_1) makes SQIFs suitable for high precision measurements of the absolute magnetic field. The experimental results are discussed in view of potential applications of high-T_c SQIFs in magnetometry.Comment: 4 pages, 2 figure

    Observation of Spontaneous Brillouin Cooling

    Full text link
    While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, a Brillouin cooling regime. Cooling is mediated by an optical pump, and scattered light, that beat and electrostrictively attenuate the Brownian motion of the mechanical mode.Comment: Supplementary material include

    Stability of Resonant Opto-Mechanical Oscillators

    Full text link
    We theoretically study the frequency stability of an opto-mechanical radio frequency oscillator based on resonant interaction of two optical and one mechanical modes of the same optical microcavity. A generalized expression for the phase noise of the oscillator is derived using Langevin formalism and compared to the phase noise of existing electronic oscillators.Comment: 6 pages, 1 figur

    Dynamics of SNARE Assembly and Disassembly during Sperm Acrosomal Exocytosis

    Get PDF
    The dynamics of SNARE assembly and disassembly during membrane recognition and fusion is a central issue in intracellular trafficking and regulated secretion. Exocytosis of sperm's single vesicle—the acrosome—is a synchronized, all-or-nothing process that happens only once in the life of the cell and depends on activation of both the GTP-binding protein Rab3 and of neurotoxin-sensitive SNAREs. These characteristics make acrosomal exocytosis a unique mammalian model for the study of the different phases of the membrane fusion cascade. By using a functional assay and immunofluorescence techniques in combination with neurotoxins and a photosensitive Ca(2+) chelator we show that, in unactivated sperm, SNAREs are locked in heterotrimeric cis complexes. Upon Ca(2+) entry into the cytoplasm, Rab3 is activated and triggers NSF/α-SNAP-dependent disassembly of cis SNARE complexes. Monomeric SNAREs in the plasma membrane and the outer acrosomal membrane are then free to reassemble in loose trans complexes that are resistant to NSF/α-SNAP and differentially sensitive to cleavage by two vesicle-associated membrane protein (VAMP)–specific neurotoxins. Ca(2+) must be released from inside the acrosome to trigger the final steps of membrane fusion that require fully assembled trans SNARE complexes and synaptotagmin. Our results indicate that the unidirectional and sequential disassembly and assembly of SNARE complexes drive acrosomal exocytosis

    Effects of magnetic field on two-dimensional Superconducting Quantum Interference Filters

    Full text link
    We present an experimental study of two-dimensional superconducting quantum interference filters (2D-SQIFs) in the presence of a magnetic field B. The dependences of the dc voltage on the applied magnetic field are characterized by a unique delta-like dip at B=0, which depends on the distribution of the areas of the individual loops, and on the bias current. The voltage span of the dip scales proportional to the number of rows simultaneously operating at the same working point. In addition, the voltage response of the 2D-SQIF is sensitive to a field gradient generated by a control line and superimposed to the homogeneous field coil. This feature opens the possibility to use 2D superconducting quantum interference filters as highly sensitive detectors of spatial gradients of magnetic field.Comment: 3 pages, 4 figures, submitted to AP

    Beyond the edge: Markerless pose estimation of speech articulators from ultrasound and camera images using DeepLabCut

    Get PDF
    Automatic feature extraction from images of speech articulators is currently achieved by detecting edges. Here, we investigate the use of pose estimation deep neural nets with transfer learning to perform markerless estimation of speech articulator keypoints using only a few hundred hand-labelled images as training input. Midsagittal ultrasound images of the tongue, jaw, and hyoid and camera images of the lips were hand-labelled with keypoints, trained using DeepLabCut and evaluated on unseen speakers and systems. Tongue surface contours interpolated from estimated and hand-labelled keypoints produced an average mean sum of distances (MSD) of 0.93, s.d. 0.46 mm, compared with 0.96, s.d. 0.39 mm, for two human labellers, and 2.3, s.d. 1.5 mm, for the best performing edge detection algorithm. A pilot set of simultaneous electromagnetic articulography (EMA) and ultrasound recordings demonstrated partial correlation among three physical sensor positions and the corresponding estimated keypoints and requires further investigation. The accuracy of the estimating lip aperture from a camera video was high, with a mean MSD of 0.70, s.d. 0.56, mm compared with 0.57, s.d. 0.48 mm for two human labellers. DeepLabCut was found to be a fast, accurate and fully automatic method of providing unique kinematic data for tongue, hyoid, jaw, and lips.https://doi.org/10.3390/s2203113322pubpub

    Two tone response of radiofrequency signals using the voltage output of a Superconducting Quantum Interference Filter

    Full text link
    In the presence of weak time harmonic electromagnetic fields, Superconducting Quantum Interference Filters (SQIFs) show the typical behavior of non linear mixers. The SQIFs are manufactured from high-T_c grain boundary Josephson junctions and operated in active microcooler. The dependence of dc voltage output V_dc vs. static external magnetic field B is non-periodic and consists of a well pronounced unique dip at zero field, with marginal side modulations at higher fields. We have successfully exploited the parabolic shape of the voltage dip around B=0 to mix quadratically two external time harmonic rf-signals, at frequencies f_1 and f_2 below the Josephson frequency f_J, and detect the corresponding mixing signal at f_1-f_2. When the mixing takes place on the SQIF current-voltage characteristics the component at 2f_2 - f_1 is present. The experiments suggest potential applications of a SQIF as a non-linear mixing device, capable to operate at frequencies from dc to few GHz with a large dynamic range.Comment: 10 pages, 3 Figures, submitted to J. Supercond. (as proceeding of the HTSHFF Symposium, June 2006, Cardiff
    • 

    corecore