5 research outputs found
Linewidth of a quantum-cascade laser assessed from its frequency noise spectrum and impact of the current driver
We report on the measurement of the frequency noise properties of a 4.6-μm distributed-feedback quantum-cascade laser (QCL) operating in continuous wave near room temperature using a spectroscopic set-up. The flank of the R(14) ro-vibrational absorption line of carbon monoxide at 2196.6cm−1 is used to convert the frequency fluctuations of the laser into intensity fluctuations that are spectrally analyzed. We evaluate the influence of the laser driver on the observed QCL frequency noise and show how only a low-noise driver with a current noise density below {\approx} 1~\mbox{nA/}\sqrt{}\mbox{Hz} allows observing the frequency noise of the laser itself, without any degradation induced by the current source. We also show how the laser FWHM linewidth, extracted from the frequency noise spectrum using a simple formula, can be drastically broadened at a rate of {\approx} 1.6~\mbox{MHz/}(\mbox{nA/}\sqrt{}\mbox{Hz}) for higher current noise densities of the driver. The current noise of commercial QCL drivers can reach several \mbox{nA/}\sqrt{}\mbox{Hz} , leading to a broadening of the linewidth of our QCL of up to several megahertz. To remedy this limitation, we present a low-noise QCL driver with only 350~\mbox{pA/}\sqrt{}\mbox{Hz} current noise, which is suitable to observe the ≈550kHz linewidth of our QC
Quantum cascade laser frequency stabilisation at the sub-Hz level
Quantum Cascade Lasers (QCL) are increasingly being used to probe the
mid-infrared "molecular fingerprint" region. This prompted efforts towards
improving their spectral performance, in order to reach ever-higher resolution
and precision. Here, we report the stabilisation of a QCL onto an optical
frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and
10-14, respectively. The comb is stabilised to a remote near-infrared
ultra-stable laser referenced to frequency primary standards, whose signal is
transferred via an optical fibre link. The stability and frequency traceability
of our QCL exceed those demonstrated so far by two orders of magnitude. As a
demonstration of its capability, we then use it to perform high-resolution
molecular spectroscopy. We measure absorption frequencies with an 8x10-13
relative uncertainty. This confirms the potential of this setup for ultra-high
precision measurements with molecules, such as our ongoing effort towards
testing the parity symmetry by probing chiral species